Refine
Year of publication
Institute
Has Fulltext
- yes (82) (remove)
Document Type
- Conference Proceeding (50)
- Article (29)
- Lecture (3)
Keywords
- Finite-Elemente-Methode (16)
- Einspielen <Werkstoff> (13)
- shakedown analysis (8)
- FEM (6)
- Clusterion (5)
- limit analysis (5)
- Air purification (4)
- Einspielanalyse (4)
- Hämoglobin (4)
- Limit analysis (4)
- Luftreiniger (4)
- Plasmacluster ion technology (4)
- Raumluft (4)
- Shakedown (4)
- Shakedown analysis (4)
- Sonde (4)
- Technische Mechanik (4)
- Traglast (4)
- Traglastanalyse (4)
- shakedown (4)
- Eisschicht (3)
- Kohlenstofffaser (3)
- Lipopolysaccharide (3)
- lipopolysaccharides (3)
- ratchetting (3)
- Analytischer Zulaessigkeitsnachweis (2)
- Bruchmechanik (2)
- Druckbeanspruchung (2)
- Druckbehälter (2)
- Druckbelastung (2)
- Einspiel-Analyse (2)
- Erythrozyt (2)
- Fehlerstellen (2)
- Fibroblast (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- Ratcheting (2)
- Rohr (2)
- Rohrbruch (2)
- Stahl (2)
- Stickstoffmonoxid (2)
- burst pressure (2)
- burst tests (2)
- celldrum technology (2)
- flaw (2)
- limit load (2)
- load limit (2)
- nanostructured carbonized plant parts (2)
- nanostrukturierte carbonisierte Pflanzenteile (2)
- nitric oxide gas (2)
- pipes (2)
- plant scanner (2)
- tension–torsion loading (2)
- vessels (2)
- Adsorption (1)
- Alternating plasticity (1)
- Analysis (1)
- Anastomose (1)
- Anastomosis (1)
- Arthosetherapie (1)
- Aufschlagversuch (1)
- Autofluoreszenzverfahren (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Bacterial cellulose (1)
- Bakterien (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Bioreaktor (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- Carbon sources (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Convex optimization (1)
- Cost-effectiveness (1)
- Culture media (1)
- Dattel (1)
- Deformation (1)
- Dekontamination (1)
- Design-by-analysis (1)
- Druckgeräte (1)
- ELISA (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elastodynamik (1)
- Elastostatics (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Environmental impact (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Exact Ilyushin yield surface (1)
- Experiment (1)
- FEM-Programm (1)
- FEM-computation (1)
- Festkörper (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fließgrenze (1)
- Fußball (1)
- Geriatric (1)
- Global and local collapse (1)
- Gonarthrose (1)
- Grenzwertberechnung (1)
- Harnleiter (1)
- Hemoglobin structure (1)
- Hip fractures (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hämoglobinstruktur (1)
- Kinematics (1)
- Kinetics (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Körpertemperatur (1)
- LISA (1)
- Lichtstreuungsbasierte Instrumente (1)
- MBST (1)
- Materialermüdung (1)
- Mechanics (1)
- Mechanische Beanspruchung (1)
- Medusomyces gisevi (1)
- Multi-dimensional wave propagation (1)
- Natriumhypochlorit (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Organkultur (1)
- Osteoporose (1)
- Osteoporosis (1)
- PFM (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenstress (1)
- Plastizität (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proteine (1)
- Random variable (1)
- Ratchetting (1)
- Red blood cell storage (1)
- Schienbeinschoner (1)
- Schwammknochen (1)
- Sensitivity (1)
- Sepsis (1)
- Shakedown criterion (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Statics (1)
- Strukturanalyse (1)
- Temperaturabhängigkeit (1)
- Tendons (1)
- Tissue Engineering (1)
- Torsion (1)
- Torsionsbelastung (1)
- Tragfähigkeit (1)
- Ultrasound (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- Zug-Druck Belastung (1)
- Zug-Druck-Beanspruchung (1)
- Zug-Druck-Belastung (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- alternierend Verformbarkeit (1)
- aromatic amines (1)
- arthrosis therapy (1)
- autofluorescence-based detection system (1)
- bicharacteristics (1)
- bone density (1)
- bone structure (1)
- cancellous bone (1)
- carbonized rice husk (1)
- contractile tension (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- direct method (1)
- ecological structure (1)
- elastic solids (1)
- epithelization (1)
- fatigue analyses (1)
- finite element analysis (1)
- fortschreitende plastische Deformation (1)
- gonarthrosis (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- human dermal fibroblasts (1)
- hydrogel (1)
- kontraktile Spannung (1)
- konvexe Optimierung (1)
- light scattering analysis (1)
- limit and shakedown analysis (1)
- linear kinematic hardening (1)
- load carrying capacity (1)
- lower bound theorem (1)
- material shakedown (1)
- mechanical waves (1)
- metagenomics (1)
- microbial diversity (1)
- naphtols (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- phenols (1)
- plant stress (1)
- plasma generated ions (1)
- plastic deformation (1)
- probabilistic fracture mechanics (1)
- protein (1)
- reliability (1)
- reliability analysis (1)
- rhAPC (1)
- second-order reliability method (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- subglacial aquatic ecosystems (1)
- subsurface ice (1)
- subsurface ice research (1)
- subsurface probe (1)
- thermal ratcheting (1)
- water bridge phenomenon (1)
- wound healing (1)
- yield stress (1)
As a deduction from these results, we can conclude that proteins mainly in vitro, denaturate totally at a temperature between 57°C -62°C, and they also affected by NO and different ions types. In which mainly, NO cause earlier protein denaturation, which means that, NO has a destabilizing effect on proteins, and also different ions will alter the protein denaturation in which, some ions will cause earlier protein denaturation while others not.
The ”IceMole“ is a novel maneuverable subsurface ice probe for clean in-situ analysis and sampling of subsurface ice and subglacial water/brine. It is developed and build at FH Aachen University of Applied Sciences’ Astronautical Laboratory. A first prototype was successfully tested on the Swiss Morteratsch glacier in 2010. Clean sampling is achieved with a hollow ice screw (as it is used in mountaineering) at the tip of the probe. Maneuverability is achieved with a differentially heated melting head. Funded by the German Space Agency (DLR), a consortium led by FH Aachen currently develops a much more advanced IceMole probe, which includes a sophisticated system for obstacle avoidance, target detection, and navigation in the ice. We intend to use this probe for taking clean samples of subglacial brine at the Blood Falls (McMurdo Dry Valleys, East Antarctica) for chemical and microbiological analysis. In our conference contribution, we 1) describe the IceMole design, 2) report the results of the field tests of the first prototype on the Morteratsch glacier, 3) discuss the probe’s potential for the clean in-situ analysis and sampling of subsurface ice and subglacial liquids, and 4) outline the way ahead in the development of this technology.
Cement augmentation is an emerging surgical procedure in which bone cement is used to infiltrate and reinforce osteoporotic vertebrae. Although this infiltration procedure has been widely applied, it is performed empirically and little is known about the flow characteristics of cement during the injection process. We present a theoretical and experimental approach to investigate the intertrabecular bone permeability during the infiltration procedure. The cement permeability was considered to be dependent on time, bone porosity, and cement viscosity in our analysis. In order to determine the time-dependent permeability, ten cancellous bone cores were harvested from osteoporotic vertebrae, infiltrated with acrylic cement at a constant flow rate, and the pressure drop across the cores during the infiltration was measured. The viscosity dependence of the permeability was determined based on published experimental data. The theoretical model for the permeability as a function of bone porosity and time was then fit to the testing data. Our findings suggest that the intertrabecular bone permeability depends strongly on time. For instance, the initial permeability (60.89 mm4/N.s) reduced to approximately 63% of its original value within 18 seconds. This study is the first to analyze cement flow through osteoporotic bone. The theoretical and experimental models provided in this paper are generic. Thus, they can be used to systematically study and optimize the infiltration process for clinical practice.
Contractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity
(2021)
Vigorous exercise countermeasures in microgravity can largely attenuate muscular degeneration, albeit the extent of applied loading is key for the extent of muscle wasting. Running on the International Space Station is usually performed with maximum loads of 70% body weight (0.7 g). However, it has not been investigated how the reduced musculoskeletal loading affects muscle and series elastic element dynamics, and thereby force and power generation. Therefore, this study examined the effects of running on the vertical treadmill facility, a ground-based analog, at simulated 0.7 g on gastrocnemius medialis contractile behavior. The results reveal that fascicle−series elastic element behavior differs between simulated hypogravity and 1 g running. Whilst shorter peak series elastic element lengths at simulated 0.7 g appear to be the result of lower muscular and gravitational forces acting on it, increased fascicle lengths and decreased velocities could not be anticipated, but may inform the development of optimized running training in hypogravity. However, whether the alterations in contractile behavior precipitate musculoskeletal degeneration warrants further study.
The international partnership of space agencies has agreed to proceed forward to the Moon sustainably. Activities on the Lunar surface (0.16 g) will allow crewmembers to advance the exploration skills needed when expanding human presence to Mars (0.38 g). Whilst data from actual hypogravity activities are limited to the Apollo missions, simulation studies have indicated that ground reaction forces, mechanical work, muscle activation, and joint angles decrease with declining gravity level. However, these alterations in locomotion biomechanics do not necessarily scale to the gravity level, the reduction in gastrocnemius medialis activation even appears to level off around 0.2 g, while muscle activation pattern remains similar. Thus, it is difficult to predict whether gastrocnemius medialis contractile behavior during running on Moon will basically be the same as on Mars. Therefore, this study investigated lower limb joint kinematics and gastrocnemius medialis behavior during running at 1 g, simulated Martian gravity, and simulated Lunar gravity on the vertical treadmill facility. The results indicate that hypogravity-induced alterations in joint kinematics and contractile behavior still persist between simulated running on the Moon and Mars. This contrasts with the concept of a ceiling effect and should be carefully considered when evaluating exercise prescriptions and the transferability of locomotion practiced in Lunar gravity to Martian gravity.
Background
Hip fractures are a common and costly health problem, resulting in significant morbidity and mortality, as well as high costs for healthcare systems, especially for the elderly. Implementing surgical preventive strategies has the potential to improve the quality of life and reduce the burden on healthcare resources, particularly in the long term. However, there are currently limited guidelines for standardizing hip fracture prophylaxis practices.
Methods
This study used a cost-effectiveness analysis with a finite-state Markov model and cohort simulation to evaluate the primary and secondary surgical prevention of hip fractures in the elderly. Patients aged 60 to 90 years were simulated in two different models (A and B) to assess prevention at different levels. Model A assumed prophylaxis was performed during the fracture operation on the contralateral side, while Model B included individuals with high fracture risk factors. Costs were obtained from the Centers for Medicare & Medicaid Services, and transition probabilities and health state utilities were derived from available literature. The baseline assumption was a 10% reduction in fracture risk after prophylaxis. A sensitivity analysis was also conducted to assess the reliability and variability of the results.
Results
With a 10% fracture risk reduction, model A costs between $8,850 and $46,940 per quality-adjusted life-year ($/QALY). Additionally, it proved most cost-effective in the age range between 61 and 81 years. The sensitivity analysis established that a reduction of ≥ 2.8% is needed for prophylaxis to be definitely cost-effective. The cost-effectiveness at the secondary prevention level was most sensitive to the cost of the contralateral side’s prophylaxis, the patient’s age, and fracture treatment cost. For high-risk patients with no fracture history, the cost-effectiveness of a preventive strategy depends on their risk profile. In the baseline analysis, the incremental cost-effectiveness ratio at the primary prevention level varied between $11,000/QALY and $74,000/QALY, which is below the defined willingness to pay threshold.
Conclusion
Due to the high cost of hip fracture treatment and its increased morbidity, surgical prophylaxis strategies have demonstrated that they can significantly relieve the healthcare system. Various key assumptions facilitated the modeling, allowing for adequate room for uncertainty. Further research is needed to evaluate health-state-associated risks.
One of interesting but not well known water properties is related to appearance of highly ordered structures in response to strong electrical field. In 1893 Sir William Armstrong placed a cotton thread between two wine glasses filled with chemically pure water. When high DC voltage was applied between the glasses, a connection consisting of water formed, producing a "water bridge"