Refine
Year of publication
Document Type
- Conference Proceeding (161) (remove)
Keywords
- Finite-Elemente-Methode (11)
- Einspielen <Werkstoff> (6)
- shakedown analysis (6)
- Clusterion (4)
- Limit analysis (4)
- Sonde (4)
- limit analysis (4)
- solar sail (4)
- Air purification (3)
- Eisschicht (3)
- Hämoglobin (3)
- Luftreiniger (3)
- MASCOT (3)
- Plasmacluster ion technology (3)
- Raumluft (3)
- Shakedown (3)
- Shakedown analysis (3)
- Traglast (3)
- Bruchmechanik (2)
- Einspielanalyse (2)
- Erythrozyt (2)
- FEM (2)
- GOSSAMER-1 (2)
- Kohlenstofffaser (2)
- Lipopolysaccharide (2)
- Ratcheting (2)
- Spacecraft (2)
- Stickstoffmonoxid (2)
- Traglastanalyse (2)
- Trajectory Optimization (2)
- celldrum technology (2)
- lipopolysaccharides (2)
- multiple NEA rendezvous (2)
- nitric oxide gas (2)
- ratchetting (2)
- shakedown (2)
- small spacecraft (2)
- Adsorption (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomose (1)
- Anastomosis (1)
- Antarctica (1)
- Asteroid Deflection (1)
- Attitude dynamics (1)
- Autofluoreszenzverfahren (1)
- Automated Optimization (1)
- Bakterien (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Chance constrained programming (1)
- Dattel (1)
- Dekontamination (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- EEG (1)
- Einspiel-Analyse (1)
- Elastodynamik (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Evolution of damage (1)
- Evolutionary Neurocontrol (1)
- Exact Ilyushin yield surface (1)
- Extension fracture (1)
- Extension strain criterion (1)
- FEM-Programm (1)
- FEM-computation (1)
- Fehlerstellen (1)
- Festkörper (1)
- Fibroblast (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Force (1)
- Gossamer (1)
- Gossamer structures (1)
- Hybrid Propellants (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Impedance Spectroscopy (1)
- Interplanetary flight (1)
- Iterative learning control (1)
- Jupiter (1)
- Knee (1)
- Körpertemperatur (1)
- LISA (1)
- Lichtstreuungsbasierte Instrumente (1)
- Load modeling (1)
- Low-Thrust Propulsion (1)
- Mars (1)
- Mechanische Beanspruchung (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Multiphase (1)
- Natriumhypochlorit (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Orbital dynamics (1)
- PFM (1)
- PHILAE (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Planetary Protection (1)
- Planetary exploration (1)
- Proteine (1)
- Random variable (1)
- Reliability of structures (1)
- Reusable Rocket Engines (1)
- Rohr (1)
- Rohrbruch (1)
- Sensitivity (1)
- Sepsis (1)
- Sequence-Search (1)
- Sleep EEG (1)
- Small Solar System Body Lander (1)
- Small Spacecraft (1)
- Solar Power Sail (1)
- Solar Sail (1)
- Solar sail (1)
- Spacecraft Trajectory Optimization (1)
- Stahl (1)
- Stochastic programming (1)
- Technische Mechanik (1)
- Torsion (1)
- Torsionsbelastung (1)
- Tragfähigkeit (1)
- Training (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Zug-Druck-Beanspruchung (1)
- Zug-Druck-Belastung (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- asteroid lander (1)
- asteroid sample return (1)
- autofluorescence-based detection system (1)
- biopotential electrodes (1)
- burst pressure (1)
- burst tests (1)
- contractile tension (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- finite element analysis (1)
- flaw (1)
- flotilla missions (1)
- habitability (1)
- heliosphere (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- hydrogel (1)
- ice moons (1)
- icy moons (1)
- ion propulsion (1)
- kontraktile Spannung (1)
- life detection (1)
- light scattering analysis (1)
- limit and shakedown analysis (1)
- limit load (1)
- linear kinematic hardening (1)
- load carrying capacity (1)
- load limit (1)
- low-thrust (1)
- low-thrust trajectory optimization (1)
- lower bound theorem (1)
- material shakedown (1)
- mechanical waves (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- near-Earth asteroid (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- pipes (1)
- planetary defence (1)
- plant scanner (1)
- plasma generated ions (1)
- plastic deformation (1)
- probabilistic fracture mechanics (1)
- protein (1)
- reliability (1)
- responsive space (1)
- rhAPC (1)
- sample return (1)
- second-order reliability method (1)
- sensors (1)
- small solar system body characterisation (1)
- small spacecraft asteroid lander (1)
- small spacecraft solar sail (1)
- solar sails (1)
- solar system (1)
- space missions (1)
- subglacial aquatic ecosystems (1)
- subsurface ice (1)
- subsurface ice research (1)
- subsurface probe (1)
- system engineering (1)
- tension–torsion loading (1)
- underwater vehicle (1)
- vessels (1)
- water bridge phenomenon (1)
The ”IceMole“ is a novel maneuverable subsurface ice probe for clean in-situ analysis and sampling of subsurface ice and subglacial water/brine. It is developed and build at FH Aachen University of Applied Sciences’ Astronautical Laboratory. A first prototype was successfully tested on the Swiss Morteratsch glacier in 2010. Clean sampling is achieved with a hollow ice screw (as it is used in mountaineering) at the tip of the probe. Maneuverability is achieved with a differentially heated melting head. Funded by the German Space Agency (DLR), a consortium led by FH Aachen currently develops a much more advanced IceMole probe, which includes a sophisticated system for obstacle avoidance, target detection, and navigation in the ice. We intend to use this probe for taking clean samples of subglacial brine at the Blood Falls (McMurdo Dry Valleys, East Antarctica) for chemical and microbiological analysis. In our conference contribution, we 1) describe the IceMole design, 2) report the results of the field tests of the first prototype on the Morteratsch glacier, 3) discuss the probe’s potential for the clean in-situ analysis and sampling of subsurface ice and subglacial liquids, and 4) outline the way ahead in the development of this technology.
As a deduction from these results, we can conclude that proteins mainly in vitro, denaturate totally at a temperature between 57°C -62°C, and they also affected by NO and different ions types. In which mainly, NO cause earlier protein denaturation, which means that, NO has a destabilizing effect on proteins, and also different ions will alter the protein denaturation in which, some ions will cause earlier protein denaturation while others not.
Conventional EEG devices cannot be used in everyday life and
hence, past decade research has been focused on Ear-EEG for mobile,
at-home monitoring for various applications ranging from
emotion detection to sleep monitoring. As the area available for
electrode contact in the ear is limited, the electrode size and location
play a vital role for an Ear-EEG system. In this investigation, we
present a quantitative study of ear-electrodes with two electrode
sizes at different locations in a wet and dry configuration. Electrode
impedance scales inversely with size and ranges from 450 kΩ to
1.29 MΩ for dry and from 22 kΩ to 42 kΩ for wet contact at 10 Hz.
For any size, the location in the ear canal with the lowest impedance
is ELE (Left Ear Superior), presumably due to increased contact
pressure caused by the outer-ear anatomy. The results can be used
to optimize signal pickup and SNR for specific applications. We
demonstrate this by recording sleep spindles during sleep onset
with high quality (5.27 μVrms).
Pulmonary arterial cannulation is a common and effective method for percutaneous mechanical circulatory support for concurrent right heart and respiratory failure [1]. However, limited data exists to what effect the positioning of the cannula has on the oxygen perfusion throughout the pulmonary artery (PA). This study aims to evaluate, using computational fluid dynamics (CFD), the effect of different cannula positions in the PA with respect to the oxygenation of the different branching vessels in order for an optimal cannula position to be determined. The four chosen different positions (see Fig. 1) of the cannulas are, in the lower part of the main pulmonary artery (MPA), in the MPA at the junction between the right pulmonary artery (RPA) and the left pulmonary artery (LPA), in the RPA at the first branch of the RPA and in the LPA at the first branch of the LPA.