Refine
Year of publication
Institute
Document Type
- Article (537) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- FEM (4)
- Finite-Elemente-Methode (4)
- CellDrum (3)
- shakedown analysis (3)
- Einspielanalyse (2)
- Lipopolysaccharide (2)
- Shakedown analysis (2)
- Stiffness (2)
- Traglastanalyse (2)
- bacterial cellulose (2)
- carbonized rice husk (2)
- damage (2)
- limit analysis (2)
- locomotion (2)
- muscle fascicle behavior (2)
- prebiotic (2)
- shakedown (2)
- ultrasound (2)
- ultrasound imaging (2)
- Achilles tendon (1)
- Adaptive control (1)
- Ageing (1)
- Air purification (1)
- AlterG (1)
- Alternating plasticity (1)
- Alzheimer's disease (1)
- Analysis (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Antarctic Glaciology (1)
- Architectural gear ratio (1)
- Arthosetherapie (1)
- Assistive technology (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Automatic control (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Bacillus sp (1)
- Bacterial cellulose (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Biocomposites (1)
- Biomechanical simulation (1)
- Bioreaktor (1)
- Biosolubilization (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- Carbon sources (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Cell permeability (1)
- Cellular force (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Cementoblast (1)
- Circular Dichroism (1)
- Clusterion (1)
- Coal (1)
- Compression (1)
- Computational biomechanics (1)
- Constitutive model (1)
- Contractile tension (1)
- Convex optimization (1)
- Cost-effectiveness (1)
- Culture media (1)
- DLR-ESTEC GOSSAMER roadmap for solar sailing (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deformation (1)
- Design-by-analysis (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Distorsion des oberen Sprunggelenks (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Druckgeräte (1)
- Drug simulation (1)
- ELISA (1)
- ES-FEM (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Electromechanical modeling (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Environmental impact (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Experiment (1)
- External knee adduction moments (1)
- Extraterrestrial Glaciology (1)
- FS-FEM (1)
- Fehlerstellen (1)
- Fibroblast (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Fließgrenze (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Fußball (1)
- GOSSAMER-1 (1)
- Geriatric (1)
- Glaciological instruments and methods (1)
- Glaucoma (1)
- Global and local collapse (1)
- Gonarthrose (1)
- Grenzwertberechnung (1)
- H2 (1)
- Haemodialysis (1)
- Handbike (1)
- Harnleiter (1)
- Heart tissue culture (1)
- Hemoglobin structure (1)
- Hip fractures (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Human-Computer interaction (1)
- Hydrogenotrophic methanogens (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Interstellar objects (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ion channels (1)
- Iterative learning control (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Kohlenstofffaser (1)
- LPS (1)
- Lactobacillus rhamnosus GG (1)
- Limit analysis (1)
- Liver (1)
- Long COVID (1)
- Luftreiniger (1)
- MBST (1)
- Machine learning (1)
- Manipulated variables (1)
- Materialermüdung (1)
- Mechanotransduction (1)
- Medusomyces gisevi (1)
- Methane (1)
- Methanogenesis (1)
- Microcirculation (1)
- Mild cognitive impairment (1)
- Missions (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Natural fibres (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-parallel fissures (1)
- Nucleus Pulposus (1)
- Ocular blood flow (1)
- Organkultur (1)
- Osteoporose (1)
- Osteoporosis (1)
- Paralympic sport (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Pflanzenstress (1)
- Pharmacology (1)
- Physiology (1)
- Plasmacluster ion technology (1)
- Plastizität (1)
- Polymer-matrix composites (1)
- Post-COVID-19 syndrome (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- RVA (1)
- Ratchetting (1)
- Raumluft (1)
- Recombinant activated protein C (1)
- Red blood cell storage (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Robotic rehabilitation (1)
- Rohr (1)
- Rohrbruch (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- Schienbeinschoner (1)
- Schwammknochen (1)
- Septic cardiomyopathy (1)
- Shakedown (1)
- Shakedown criterion (1)
- Simulation (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Small spacecraft (1)
- Solar sail (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Stahl (1)
- Stress concentrations (1)
- Strukturanalyse (1)
- Subclacial exploration (1)
- Subglacial lakes (1)
- SunRav BookEditor (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Temperaturabhängigkeit (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tendons (1)
- Tension (1)
- Tissue Engineering (1)
- Traglast (1)
- Trajectories (1)
- Ultrasound (1)
- Uniaxial compression test (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Visual field asymmetry (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- Zug-Druck Belastung (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- alternierend Verformbarkeit (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- aortic perfusion (1)
- aromatic amines (1)
- arthrosis therapy (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- biofilms (1)
- biomechanics (1)
- biopotential electrodes (1)
- bone density (1)
- bone structure (1)
- burst pressure (1)
- burst tests (1)
- cancellous bone (1)
- cardiomyocyte biomechanics (1)
- cell aerosolization (1)
- cell atomization (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- coculture (1)
- cognitive impairment (1)
- community dwelling (1)
- computational fluid dynamics analysis (1)
- connective tissue (1)
- constitutive modeling (1)
- constructive alignment (1)
- correlation (1)
- crop yield (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- direct method (1)
- distance learning (1)
- distorted element (1)
- double-lumen tube intubation (1)
- drop jump (1)
- e-books (1)
- e-issues (1)
- ecological structure (1)
- elastic solids (1)
- electromyography (1)
- endoluminal (1)
- energy absorption (1)
- energy dissipation (1)
- epithelization (1)
- examination (1)
- exopolysaccharides (1)
- extracorporeal membrane oxygenation (1)
- fatigue analyses (1)
- fibulare Bandruptur (1)
- flaw (1)
- force generation (1)
- forehead EEG (1)
- fortschreitende plastische Deformation (1)
- gait (1)
- gonarthrosis (1)
- healthy aging (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- human dermal fibroblasts (1)
- humic acid (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- immobilization (1)
- impedance spectroscopy (1)
- in-ear EEG (1)
- intraclass correlation coefficient (1)
- konvexe Optimierung (1)
- lignite (1)
- limit load (1)
- lipopolysaccharide (1)
- lipopolysaccharides (1)
- load limit (1)
- long-term retention (1)
- low-rank coal (1)
- mechanical buffer (1)
- metagenomics (1)
- microbial diversity (1)
- multimodal (1)
- muscle mechanics (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- naphtols (1)
- non-simplex S-FEM elements (1)
- overload (1)
- parabolic flight (1)
- performance testing (1)
- phenols (1)
- physiology (1)
- pipes (1)
- plant scanner (1)
- plant stress (1)
- practical learning (1)
- prevention (1)
- psychosocial (1)
- pullulan (1)
- ratchetting (1)
- rehabilitation (1)
- reliability analysis (1)
- reliability of structures (1)
- retinal microvasculature (1)
- retinal vessels (1)
- running (1)
- rupture of the fibular ligament (1)
- sEMG (1)
- sarcomere operating length (1)
- series elastic element behavior (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- shoulder (1)
- simulation (1)
- smooth muscle contraction (1)
- softs (1)
- soil amendment (1)
- soil health (1)
- soil remediation (1)
- sprint start (1)
- standard error of measurement (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- surface modification (1)
- survival (1)
- tendon rupture (1)
- tension–torsion loading (1)
- test-retest reliability (1)
- thermal ratcheting (1)
- tri-lineage differentiation (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- unloading (1)
- vessels (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- walking (1)
- walking gait (1)
- wound healing (1)
- yield stress (1)
Performing tasks, such as running and jumping, requires activation of the agonist and antagonist muscles before (motor unit pre-activation) and during movement performance (Santello and Mcdonagh, 1998). A well-timed and regulated muscle activation elicits a stretch-shortening cycle (SSC) response, naturally occurring in bouncing movements (Ishikawa and Komi, 2004; Taube et al., 2012). By definition, the SSC describes the stretching of a pre-activated muscle-tendon complex immediately followed by a muscle shortening in the concentric push-off phase (Komi, 1984).
Given the importance of SSC actions for human movement, it is not surprising that many studies investigated the biomechanics of this phenomenon; in particular, drop jumps (DJs) represent a good paradigm to study muscle fascicle and tendon behavior in ballistic movements involving the SSC.
Within a DJ, three main phases [pre-activation, braking, and push-off (PO; Komi, 2000)] have been recognized and extensively studied in common and challenging conditions, such as changes in load, falling height, or simulated hypo-gravity (Avela et al., 1994; Arampatzis et al., 2001; Fukashiro et al., 2005; Ishikawa et al., 2005; Sousa et al., 2007; Ritzmann et al., 2016; Helm et al., 2020).
These studies show that the timing and amount of triceps-surae muscle-tendon unit pre-activation in DJs are differentially regulated based on the load applied to the muscle, being optimal in normal “Earth” gravity conditions (Avela et al., 1994), but decreased in simulated hypo-gravity, hyper-gravity (Avela et al., 1994; Ritzmann et al., 2016), or unknown conditions (i.e., unknown falling heights; Helm et al., 2020). Some authors indicated that, when falling from heights different from the optimal one [defined as the drop height giving a maximum DJ performance indicated as peak ground reaction force (GRF) or jump high], electromyographic (EMG) activity of the plantar flexors increases from lower than optimal to higher than optimal heights (Ishikawa and Komi, 2004; Sousa et al., 2007).
These findings highlight the ability of the central nervous system to regulate the timing and amount of pre-activation according to different jumping conditions, thus regulating muscle fascicle length, tendon and joint stiffness as well as position, in order to safely land on the ground and quickly re-bounce.
Similarly, to pre-activation, also in the braking phase, the plantar flexors are differentially regulated. In optimal height (i.e., load) jumping conditions, gastrocnemius medialis (GM) fascicles shorten at early ground contact (possibly due to the intervention of the stretch reflex; Gollhofer et al., 1992) and behave quasi-isometrically in the late braking phase, enabling tendon elongation, and storage of elastic energy (Gollhofer et al., 1992; Fukashiro et al., 2005; Sousa et al., 2007). When increasing the falling height (augmenting the impact GRF), the quasi-isometric behavior of fascicles disappears, and fast fascicle lengthening occurs (Ishikawa et al., 2005; Sousa et al., 2007).
In the third and last PO phase, fascicles shorten and the tendon releases the elastic energy previously stored. Bobbert et al. (1987) reported no influence of jumping height on the work done and on the net vertical impulse assessed during PO; this observation suggests that, despite an optimal DJ performance might be achieved only in specific conditions (falling heights, loads), the central nervous system seems to be able to regulate muscle behavior in order to effectively perform the required task also in challenging situations.
Although the regulation of triceps-surae muscle-tendon unit in DJs has been extensively investigated, very few studies focused on sarcomeres behavior during the performance of this SSC movement (Kurokawa et al., 2003; Fukashiro et al., 2005, 2006). Sarcomeres represent muscle contractile units and are known to express different amounts of force depending on their length (Gordon et al., 1966; Walker and Schrodt, 1974); thus, understanding the time course of their responses during DJs is fundamental to gain further insights into muscle force-generating capacity. In vivo measurement of sarcomere length in humans has been so far been performed only in static positions and under highly controlled experimental conditions (Llewellyn et al., 2008; Sanchez et al., 2015). Instead, human sarcomere length estimation (achieved by dividing GM measured fascicle length for a fixed sarcomere number) in dynamic contractions provided an indirect measure of sarcomere operating range during squat jump, countermovement jump, and DJ (Fukashiro et al., 2005, 2006; Kurokawa et al., 2003). The results of these studies showed that sarcomeres operate in the ascending limb of their length-tension (L-T) relationship in all types of jumps, and particularly so in DJ.
However, most of the available observations on sarcomere and muscle fascicle behavior were made in condition of constant gravity. Thus, in order to understand how sarcomere and muscle fascicle length are regulated in variable gravity conditions, we performed experiments in a parabolic flight, involving variable gravity levels, ranging from about zero-g to about double the Earth’s gravity (1 g; Waldvogel et al., 2021).
Specifically, the aims of the present study were as follows:
1. To investigate the ability of the neuromuscular system in regulating fascicle length in response to conditions of variable gravity.
2. To estimate sarcomere operative length in the different DJ phases, in order to calculate its theoretical force production and its possible modulation in conditions of variable gravity.
We hypothesized that muscle fascicles would be differentially regulated in different gravity conditions compared to 1 g, particularly in anticipation of landing and re-bouncing in unknown gravity levels. In addition, we hypothesized that sarcomeres would operate in the upper part of the ascending limb of their L-T relationship, possibly lengthening during the braking phase (especially in hyper-gravity) while operating quasi-isometrically in 1 g.
Muscle function is compromised by gravitational unloading in space affecting overall musculoskeletal health. Astronauts perform daily exercise programmes to mitigate these effects but knowing which muscles to target would optimise effectiveness. Accurate inflight assessment to inform exercise programmes is critical due to lack of technologies suitable for spaceflight. Changes in mechanical properties indicate muscle health status and can be measured rapidly and non-invasively using novel technology. A hand-held MyotonPRO device enabled monitoring of muscle health for the first time in spaceflight (> 180 days). Greater/maintained stiffness indicated countermeasures were effective. Tissue stiffness was preserved in the majority of muscles (neck, shoulder, back, thigh) but Tibialis Anterior (foot lever muscle) stiffness decreased inflight vs. preflight (p < 0.0001; mean difference 149 N/m) in all 12 crewmembers. The calf muscles showed opposing effects, Gastrocnemius increasing in stiffness Soleus decreasing. Selective stiffness decrements indicate lack of preservation despite daily inflight countermeasures. This calls for more targeted exercises for lower leg muscles with vital roles as ankle joint stabilizers and in gait. Muscle stiffness is a digital biomarker for risk monitoring during future planetary explorations (Moon, Mars), for healthcare management in challenging environments or clinical disorders in people on Earth, to enable effective tailored exercise programmes.
Based on the European Space Agency (ESA) Science in Space Environment (SciSpacE) community White Paper “Human Physiology – Musculoskeletal system”, this perspective highlights unmet needs and suggests new avenues for future studies in musculoskeletal research to enable crewed exploration missions. The musculoskeletal system is essential for sustaining physical function and energy metabolism, and the maintenance of health during exploration missions, and consequently mission success, will be tightly linked to musculoskeletal function. Data collection from current space missions from pre-, during-, and post-flight periods would provide important information to understand and ultimately offset musculoskeletal alterations during long-term spaceflight. In addition, understanding the kinetics of the different components of the musculoskeletal system in parallel with a detailed description of the molecular mechanisms driving these alterations appears to be the best approach to address potential musculoskeletal problems that future exploratory-mission crew will face. These research efforts should be accompanied by technical advances in molecular and phenotypic monitoring tools to provide in-flight real-time feedback.
One of the priority trends of carbon nanotechnology is creation of nanocomposite systems. Such carbon nanostructured composites were produced using - raw materials based on the products of agricultural waste, such as grape stones, apricot stones, rice husk. These products have a - wide spectrum of application and can be obtained in large quantities. The Institute of Combustion Problems has carried out the work on synthesis of the nanostructured carbon sorbents for multiple applications including the field of biomedicine. The article presents the data on the synthesis and physico-chemical properties of carbonaceous sorbents using physicochemical methods of investigation: separation and purification of biomolecules; isolation of phytohormone - fusicoccin; adsorbent INGO-1 in the form of an adsorption column for blood detoxification, oral (entero) sorbent - INGO-2; the study of efferent and probiotic properties and sorption activity in regard to the lipopolysaccharide (LPS), new biocomposites - based on carbonized rice husk (CRH) and cellular microorganisms; the use of CRH in wound treatment. A new material for blood detoxication (INGO-1) has been obtained. Adsorption of p-cresyl sulfate and indoxyl sulfate has shown that active carbon adsorbent can remove clinically significant level of p-cresyl sulfate and indoxyl sulfate from human plasma. Enterosorbent INGO-2 possesses high adsorption activity in relation to Gram-negative bacteria and their endotoxins. INGO-2 slows down the growth of conditionally pathogenic microorganisms, without having a negative effect on bifido and lactobacteria. The use of enterosorbent INGO-2 for sorption therapy may provide a solution to a complex problem - detoxication of the digestive tract and normalization of the intestinal micro ecology. The immobilized probiotic called "Riso-lact" was registered at the Ministry of Health of the Republic of Kazakhstan as a biologically active food additive. The developed technology is patented and provides production of the medicine in the form of freeze-dried biomass immobilized in vials.
The Saturnian moon Enceladus with its extensive water bodies underneath a thick ice sheet cover is a potential candidate for extraterrestrial life. Direct exploration of such extraterrestrial aquatic ecosystems requires advanced access and sampling technologies with a high level of autonomy. A new technological approach has been developed as part of the collaborative research project Enceladus Explorer (EnEx). The concept is based upon a minimally invasive melting probe called the IceMole. The force-regulated, heater-controlled IceMole is able to travel along a curved trajectory as well as upwards. Hence, it allows maneuvers which may be necessary for obstacle avoidance or target selection. Maneuverability, however, necessitates a sophisticated on-board navigation system capable of autonomous operations. The development of such a navigational system has been the focal part of the EnEx project. The original IceMole has been further developed to include relative positioning based on in-ice attitude determination, acoustic positioning, ultrasonic obstacle and target detection integrated through a high-level sensor fusion. This paper describes the EnEx technology and discusses implications for an actual extraterrestrial mission concept.
Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment
Delayed cerebral ischemia (DCI) is a common complication after aneurysmal subarachnoid hemorrhage (aSAH) and can lead to infarction and poor clinical outcome. The underlying mechanisms are still incompletely understood, but animal models indicate that vasoactive metabolites and inflammatory cytokines produced within the subarachnoid space may progressively impair and partially invert neurovascular coupling (NVC) in the brain. Because cerebral and retinal microvasculature are governed by comparable regulatory mechanisms and may be connected by perivascular pathways, retinal vascular changes are increasingly recognized as a potential surrogate for altered NVC in the brain. Here, we used non-invasive retinal vessel analysis (RVA) to assess microvascular function in aSAH patients at different times after the ictus.
Background
Impairment of neurovascular coupling (NVC) was recently reported in the context of subarachnoid hemorrhage and may correlate with disease severity and outcome. However, previous techniques to evaluate NVC required invasive procedures. Retinal vessels may represent an alternative option for non-invasive assessment of NVC.
Methods
A prototype of an adapted retinal vessel analyzer was used to assess retinal vessel diameter in mice. Dynamic vessel analysis (DVA) included an application of monochromatic flicker light impulses in predefined frequencies for evaluating NVC. All retinae were harvested after DVA and electroretinograms were performed.
Results
A total of 104 retinal scans were conducted in 21 male mice (90 scans). Quantitative arterial recordings were feasible only in a minority of animals, showing an emphasized reaction to flicker light impulses (8 mice; 14 scans). A characteristic venous response to flicker light, however, could observed in the majority of animals. Repeated measurements resulted in a significant decrease of baseline venous diameter (7 mice; 7 scans, p < 0.05). Ex-vivo electroretinograms, performed after in-vivo DVA, demonstrated a significant reduction of transretinal signaling in animals with repeated DVA (n = 6, p < 0.001).
Conclusions
To the best of our knowledge, this is the first non-invasive study assessing murine retinal vessel response to flicker light with characteristic changes in NVC. The imaging system can be used for basic research and enables the investigation of retinal vessel dimension and function in control mice and genetically modified animals.
Muscular activity in terms of surface electromyography (sEMG) is usually normalised to maximal voluntary isometric contractions (MVICs). This study aims to compare two different MVIC-modes in handcycling and examine the effect of moving average window-size. Twelve able-bodied male competitive triathletes performed ten MVICs against manual resistance and four sport-specific trials against fixed cranks. sEMG of ten muscles [M. trapezius (TD); M. pectoralis major (PM); M. deltoideus, Pars clavicularis (DA); M. deltoideus, Pars spinalis (DP); M. biceps brachii (BB); M. triceps brachii (TB); forearm flexors (FC); forearm extensors (EC); M. latissimus dorsi (LD) and M. rectus abdominis (RA)] was recorded and filtered using moving average window-sizes of 150, 200, 250 and 300 ms. Sport-specific MVICs were higher compared to manual resistance for TB, DA, DP and LD, whereas FC, TD, BB and RA demonstrated lower values. PM and EC demonstrated no significant difference between MVIC-modes. Moving average window-size had no effect on MVIC outcomes. MVIC-mode should be taken into account when normalised sEMG data are illustrated in handcycling. Sport-specific MVICs seem to be suitable for some muscles (TB, DA, DP and LD), but should be augmented by MVICs against manual/mechanical resistance for FC, TD, BB and RA.
Optical coherence tomography : a potential tool to predict premature rupture of fetal membranes
(2013)
The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes.
Optimization of Interplanetary Rendezvous Trajectories for Solar Sailcraft Using a Neurocontroller
(2002)
Searching optimal interplanetary trajectories for low-thrust spacecraft is usually a difficult and time-consuming task that involves much experience and expert knowledge in astrodynamics and optimal control theory. This is because the convergence behavior of traditional local optimizers, which are based on numerical optimal control methods, depends on an adequate initial guess, which is often hard to find, especially for very-low-thrust trajectories that necessitate many revolutions around the sun. The obtained solutions are typically close to the initial guess that is rarely close to the (unknown) global optimum. Within this paper, trajectory optimization problems are attacked from the perspective of artificial intelligence and machine learning. Inspired by natural archetypes, a smart global method for low-thrust trajectory optimization is proposed that fuses artificial neural networks and evolutionary algorithms into so-called evolutionary neurocontrollers. This novel method runs without an initial guess and does not require the attendance of an expert in astrodynamics and optimal control theory. This paper details how evolutionary neurocontrol works and how it could be implemented. The performance of the method is assessed for three different interplanetary missions with a thrust to mass ratio <0.15mN/kg (solar sail and nuclear electric).
Purpose
The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model.
Methods
A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine.
Results
Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup.
Conclusions
Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability.
Clinical relevance
Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties.
Der vorliegende Artikel fokussiert sich auf die weibliche Belastungsinkontinenz als Insuffizienz der Speicherfunktion der Blase, auch wenn im klinischen Alltag die Harninkontinenz der Frau häufig verschiedene Ursachen hat und insbesondere eine Belastungsinkontinenz im Alter und bei neurologischer Komorbidität nur selten isoliert vorkommt.
Das kleine Becken der Frau ist sowohl als Funktions- als auch als strukturelle Einheit zu betrachten. Dabei unterliegen bei der Frau Blase, Harnröhre, Gebärmutter und Enddarm sowie die muskulären und ligamentösen Strukturen des kleinen Beckens durch Fertilitätsphase, mögliche Schwangerschaften, Geburten und Menopausen-Phase, über das „normale Altern“ hinaus, gravierenden Veränderungen.
This article focuses on female stress incontinence in the form of pelvic floor dysfunction and urethral sphincter deficiency, although isolated stress incontinence accounts for less than half of all incontinence cases. Especially in women of old age and those with neurological comorbidities, the causes of incontinence are mostly multifactorial. Also it has to be considered that the female bladder, urethra, uterus and rectum as well as the muscular and ligamentous structures of the female pelvis minor are affected by phases of fertility, possible pregnancies, births and menopause in addition to the normal ageing process.
Background
Post-COVID-19 syndrome (PCS) is a lingering disease with ongoing symptoms such as fatigue and cognitive impairment resulting in a high impact on the daily life of patients. Understanding the pathophysiology of PCS is a public health priority, as it still poses a diagnostic and treatment challenge for physicians.
Methods
In this prospective observational cohort study, we analyzed the retinal microcirculation using Retinal Vessel Analysis (RVA) in a cohort of patients with PCS and compared it to an age- and gender-matched healthy cohort (n = 41, matched out of n = 204).
Measurements and main results
PCS patients exhibit persistent endothelial dysfunction (ED), as indicated by significantly lower venular flicker-induced dilation (vFID; 3.42% ± 1.77% vs. 4.64% ± 2.59%; p = 0.02), narrower central retinal artery equivalent (CRAE; 178.1 [167.5–190.2] vs. 189.1 [179.4–197.2], p = 0.01) and lower arteriolar-venular ratio (AVR; (0.84 [0.8–0.9] vs. 0.88 [0.8–0.9], p = 0.007). When combining AVR and vFID, predicted scores reached good ability to discriminate groups (area under the curve: 0.75). Higher PCS severity scores correlated with lower AVR (R = − 0.37 p = 0.017). The association of microvascular changes with PCS severity were amplified in PCS patients exhibiting higher levels of inflammatory parameters.
Conclusion
Our results demonstrate that prolonged endothelial dysfunction is a hallmark of PCS, and impairments of the microcirculation seem to explain ongoing symptoms in patients. As potential therapies for PCS emerge, RVA parameters may become relevant as clinical biomarkers for diagnosis and therapy management.
Background
True date palms (Phoenix dactylifera L.) are impressive trees and have served as an indispensable source of food for mankind in tropical and subtropical countries for centuries. The aim of this study is to differentiate date palm tree varieties by analysing leaflet cross sections with technical/optical methods and artificial neural networks (ANN).
Results
Fluorescence microscopy images of leaflet cross sections have been taken from a set of five date palm tree cultivars (Hewlat al Jouf, Khlas, Nabot Soltan, Shishi, Um Raheem). After features extraction from images, the obtained data have been fed in a multilayer perceptron ANN with backpropagation learning algorithm.
Conclusions
Overall, an accurate result in prediction and differentiation of date palm tree cultivars was achieved with average prediction in tenfold cross-validation is 89.1% and reached 100% in one of the best ANN.