Refine
Year of publication
Institute
Document Type
- Article (537) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- FEM (4)
- Finite-Elemente-Methode (4)
- CellDrum (3)
- shakedown analysis (3)
- Einspielanalyse (2)
- Lipopolysaccharide (2)
- Shakedown analysis (2)
- Stiffness (2)
- Traglastanalyse (2)
- bacterial cellulose (2)
- carbonized rice husk (2)
- damage (2)
- limit analysis (2)
- locomotion (2)
- muscle fascicle behavior (2)
- prebiotic (2)
- shakedown (2)
- ultrasound (2)
- ultrasound imaging (2)
- Achilles tendon (1)
- Adaptive control (1)
- Ageing (1)
- Air purification (1)
- AlterG (1)
- Alternating plasticity (1)
- Alzheimer's disease (1)
- Analysis (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Antarctic Glaciology (1)
- Architectural gear ratio (1)
- Arthosetherapie (1)
- Assistive technology (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Automatic control (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Bacillus sp (1)
- Bacterial cellulose (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Biocomposites (1)
- Biomechanical simulation (1)
- Bioreaktor (1)
- Biosolubilization (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- Carbon sources (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Cell permeability (1)
- Cellular force (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Cementoblast (1)
- Circular Dichroism (1)
- Clusterion (1)
- Coal (1)
- Compression (1)
- Computational biomechanics (1)
- Constitutive model (1)
- Contractile tension (1)
- Convex optimization (1)
- Cost-effectiveness (1)
- Culture media (1)
- DLR-ESTEC GOSSAMER roadmap for solar sailing (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deformation (1)
- Design-by-analysis (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Distorsion des oberen Sprunggelenks (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Druckgeräte (1)
- Drug simulation (1)
- ELISA (1)
- ES-FEM (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Electromechanical modeling (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Environmental impact (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Experiment (1)
- External knee adduction moments (1)
- Extraterrestrial Glaciology (1)
- FS-FEM (1)
- Fehlerstellen (1)
- Fibroblast (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Fließgrenze (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Fußball (1)
- GOSSAMER-1 (1)
- Geriatric (1)
- Glaciological instruments and methods (1)
- Glaucoma (1)
- Global and local collapse (1)
- Gonarthrose (1)
- Grenzwertberechnung (1)
- H2 (1)
- Haemodialysis (1)
- Handbike (1)
- Harnleiter (1)
- Heart tissue culture (1)
- Hemoglobin structure (1)
- Hip fractures (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Human-Computer interaction (1)
- Hydrogenotrophic methanogens (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Interstellar objects (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ion channels (1)
- Iterative learning control (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Kohlenstofffaser (1)
- LPS (1)
- Lactobacillus rhamnosus GG (1)
- Limit analysis (1)
- Liver (1)
- Long COVID (1)
- Luftreiniger (1)
- MBST (1)
- Machine learning (1)
- Manipulated variables (1)
- Materialermüdung (1)
- Mechanotransduction (1)
- Medusomyces gisevi (1)
- Methane (1)
- Methanogenesis (1)
- Microcirculation (1)
- Mild cognitive impairment (1)
- Missions (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Natural fibres (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-parallel fissures (1)
- Nucleus Pulposus (1)
- Ocular blood flow (1)
- Organkultur (1)
- Osteoporose (1)
- Osteoporosis (1)
- Paralympic sport (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Pflanzenstress (1)
- Pharmacology (1)
- Physiology (1)
- Plasmacluster ion technology (1)
- Plastizität (1)
- Polymer-matrix composites (1)
- Post-COVID-19 syndrome (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- RVA (1)
- Ratchetting (1)
- Raumluft (1)
- Recombinant activated protein C (1)
- Red blood cell storage (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Robotic rehabilitation (1)
- Rohr (1)
- Rohrbruch (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- Schienbeinschoner (1)
- Schwammknochen (1)
- Septic cardiomyopathy (1)
- Shakedown (1)
- Shakedown criterion (1)
- Simulation (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Small spacecraft (1)
- Solar sail (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Stahl (1)
- Stress concentrations (1)
- Strukturanalyse (1)
- Subclacial exploration (1)
- Subglacial lakes (1)
- SunRav BookEditor (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Temperaturabhängigkeit (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tendons (1)
- Tension (1)
- Tissue Engineering (1)
- Traglast (1)
- Trajectories (1)
- Ultrasound (1)
- Uniaxial compression test (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Visual field asymmetry (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- Zug-Druck Belastung (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- alternierend Verformbarkeit (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- aortic perfusion (1)
- aromatic amines (1)
- arthrosis therapy (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- biofilms (1)
- biomechanics (1)
- biopotential electrodes (1)
- bone density (1)
- bone structure (1)
- burst pressure (1)
- burst tests (1)
- cancellous bone (1)
- cardiomyocyte biomechanics (1)
- cell aerosolization (1)
- cell atomization (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- coculture (1)
- cognitive impairment (1)
- community dwelling (1)
- computational fluid dynamics analysis (1)
- connective tissue (1)
- constitutive modeling (1)
- constructive alignment (1)
- correlation (1)
- crop yield (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- direct method (1)
- distance learning (1)
- distorted element (1)
- double-lumen tube intubation (1)
- drop jump (1)
- e-books (1)
- e-issues (1)
- ecological structure (1)
- elastic solids (1)
- electromyography (1)
- endoluminal (1)
- energy absorption (1)
- energy dissipation (1)
- epithelization (1)
- examination (1)
- exopolysaccharides (1)
- extracorporeal membrane oxygenation (1)
- fatigue analyses (1)
- fibulare Bandruptur (1)
- flaw (1)
- force generation (1)
- forehead EEG (1)
- fortschreitende plastische Deformation (1)
- gait (1)
- gonarthrosis (1)
- healthy aging (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- human dermal fibroblasts (1)
- humic acid (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- immobilization (1)
- impedance spectroscopy (1)
- in-ear EEG (1)
- intraclass correlation coefficient (1)
- konvexe Optimierung (1)
- lignite (1)
- limit load (1)
- lipopolysaccharide (1)
- lipopolysaccharides (1)
- load limit (1)
- long-term retention (1)
- low-rank coal (1)
- mechanical buffer (1)
- metagenomics (1)
- microbial diversity (1)
- multimodal (1)
- muscle mechanics (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- naphtols (1)
- non-simplex S-FEM elements (1)
- overload (1)
- parabolic flight (1)
- performance testing (1)
- phenols (1)
- physiology (1)
- pipes (1)
- plant scanner (1)
- plant stress (1)
- practical learning (1)
- prevention (1)
- psychosocial (1)
- pullulan (1)
- ratchetting (1)
- rehabilitation (1)
- reliability analysis (1)
- reliability of structures (1)
- retinal microvasculature (1)
- retinal vessels (1)
- running (1)
- rupture of the fibular ligament (1)
- sEMG (1)
- sarcomere operating length (1)
- series elastic element behavior (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- shoulder (1)
- simulation (1)
- smooth muscle contraction (1)
- softs (1)
- soil amendment (1)
- soil health (1)
- soil remediation (1)
- sprint start (1)
- standard error of measurement (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- surface modification (1)
- survival (1)
- tendon rupture (1)
- tension–torsion loading (1)
- test-retest reliability (1)
- thermal ratcheting (1)
- tri-lineage differentiation (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- unloading (1)
- vessels (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- walking (1)
- walking gait (1)
- wound healing (1)
- yield stress (1)
Delayed cerebral ischemia (DCI) is a common complication after aneurysmal subarachnoid hemorrhage (aSAH) and can lead to infarction and poor clinical outcome. The underlying mechanisms are still incompletely understood, but animal models indicate that vasoactive metabolites and inflammatory cytokines produced within the subarachnoid space may progressively impair and partially invert neurovascular coupling (NVC) in the brain. Because cerebral and retinal microvasculature are governed by comparable regulatory mechanisms and may be connected by perivascular pathways, retinal vascular changes are increasingly recognized as a potential surrogate for altered NVC in the brain. Here, we used non-invasive retinal vessel analysis (RVA) to assess microvascular function in aSAH patients at different times after the ictus.
Background
Impairment of neurovascular coupling (NVC) was recently reported in the context of subarachnoid hemorrhage and may correlate with disease severity and outcome. However, previous techniques to evaluate NVC required invasive procedures. Retinal vessels may represent an alternative option for non-invasive assessment of NVC.
Methods
A prototype of an adapted retinal vessel analyzer was used to assess retinal vessel diameter in mice. Dynamic vessel analysis (DVA) included an application of monochromatic flicker light impulses in predefined frequencies for evaluating NVC. All retinae were harvested after DVA and electroretinograms were performed.
Results
A total of 104 retinal scans were conducted in 21 male mice (90 scans). Quantitative arterial recordings were feasible only in a minority of animals, showing an emphasized reaction to flicker light impulses (8 mice; 14 scans). A characteristic venous response to flicker light, however, could observed in the majority of animals. Repeated measurements resulted in a significant decrease of baseline venous diameter (7 mice; 7 scans, p < 0.05). Ex-vivo electroretinograms, performed after in-vivo DVA, demonstrated a significant reduction of transretinal signaling in animals with repeated DVA (n = 6, p < 0.001).
Conclusions
To the best of our knowledge, this is the first non-invasive study assessing murine retinal vessel response to flicker light with characteristic changes in NVC. The imaging system can be used for basic research and enables the investigation of retinal vessel dimension and function in control mice and genetically modified animals.
Muscular activity in terms of surface electromyography (sEMG) is usually normalised to maximal voluntary isometric contractions (MVICs). This study aims to compare two different MVIC-modes in handcycling and examine the effect of moving average window-size. Twelve able-bodied male competitive triathletes performed ten MVICs against manual resistance and four sport-specific trials against fixed cranks. sEMG of ten muscles [M. trapezius (TD); M. pectoralis major (PM); M. deltoideus, Pars clavicularis (DA); M. deltoideus, Pars spinalis (DP); M. biceps brachii (BB); M. triceps brachii (TB); forearm flexors (FC); forearm extensors (EC); M. latissimus dorsi (LD) and M. rectus abdominis (RA)] was recorded and filtered using moving average window-sizes of 150, 200, 250 and 300 ms. Sport-specific MVICs were higher compared to manual resistance for TB, DA, DP and LD, whereas FC, TD, BB and RA demonstrated lower values. PM and EC demonstrated no significant difference between MVIC-modes. Moving average window-size had no effect on MVIC outcomes. MVIC-mode should be taken into account when normalised sEMG data are illustrated in handcycling. Sport-specific MVICs seem to be suitable for some muscles (TB, DA, DP and LD), but should be augmented by MVICs against manual/mechanical resistance for FC, TD, BB and RA.
Optical coherence tomography : a potential tool to predict premature rupture of fetal membranes
(2013)
The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes.
Optimization of Interplanetary Rendezvous Trajectories for Solar Sailcraft Using a Neurocontroller
(2002)
Searching optimal interplanetary trajectories for low-thrust spacecraft is usually a difficult and time-consuming task that involves much experience and expert knowledge in astrodynamics and optimal control theory. This is because the convergence behavior of traditional local optimizers, which are based on numerical optimal control methods, depends on an adequate initial guess, which is often hard to find, especially for very-low-thrust trajectories that necessitate many revolutions around the sun. The obtained solutions are typically close to the initial guess that is rarely close to the (unknown) global optimum. Within this paper, trajectory optimization problems are attacked from the perspective of artificial intelligence and machine learning. Inspired by natural archetypes, a smart global method for low-thrust trajectory optimization is proposed that fuses artificial neural networks and evolutionary algorithms into so-called evolutionary neurocontrollers. This novel method runs without an initial guess and does not require the attendance of an expert in astrodynamics and optimal control theory. This paper details how evolutionary neurocontrol works and how it could be implemented. The performance of the method is assessed for three different interplanetary missions with a thrust to mass ratio <0.15mN/kg (solar sail and nuclear electric).
Purpose
The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model.
Methods
A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine.
Results
Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup.
Conclusions
Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability.
Clinical relevance
Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties.
Der vorliegende Artikel fokussiert sich auf die weibliche Belastungsinkontinenz als Insuffizienz der Speicherfunktion der Blase, auch wenn im klinischen Alltag die Harninkontinenz der Frau häufig verschiedene Ursachen hat und insbesondere eine Belastungsinkontinenz im Alter und bei neurologischer Komorbidität nur selten isoliert vorkommt.
Das kleine Becken der Frau ist sowohl als Funktions- als auch als strukturelle Einheit zu betrachten. Dabei unterliegen bei der Frau Blase, Harnröhre, Gebärmutter und Enddarm sowie die muskulären und ligamentösen Strukturen des kleinen Beckens durch Fertilitätsphase, mögliche Schwangerschaften, Geburten und Menopausen-Phase, über das „normale Altern“ hinaus, gravierenden Veränderungen.
This article focuses on female stress incontinence in the form of pelvic floor dysfunction and urethral sphincter deficiency, although isolated stress incontinence accounts for less than half of all incontinence cases. Especially in women of old age and those with neurological comorbidities, the causes of incontinence are mostly multifactorial. Also it has to be considered that the female bladder, urethra, uterus and rectum as well as the muscular and ligamentous structures of the female pelvis minor are affected by phases of fertility, possible pregnancies, births and menopause in addition to the normal ageing process.
Background
Post-COVID-19 syndrome (PCS) is a lingering disease with ongoing symptoms such as fatigue and cognitive impairment resulting in a high impact on the daily life of patients. Understanding the pathophysiology of PCS is a public health priority, as it still poses a diagnostic and treatment challenge for physicians.
Methods
In this prospective observational cohort study, we analyzed the retinal microcirculation using Retinal Vessel Analysis (RVA) in a cohort of patients with PCS and compared it to an age- and gender-matched healthy cohort (n = 41, matched out of n = 204).
Measurements and main results
PCS patients exhibit persistent endothelial dysfunction (ED), as indicated by significantly lower venular flicker-induced dilation (vFID; 3.42% ± 1.77% vs. 4.64% ± 2.59%; p = 0.02), narrower central retinal artery equivalent (CRAE; 178.1 [167.5–190.2] vs. 189.1 [179.4–197.2], p = 0.01) and lower arteriolar-venular ratio (AVR; (0.84 [0.8–0.9] vs. 0.88 [0.8–0.9], p = 0.007). When combining AVR and vFID, predicted scores reached good ability to discriminate groups (area under the curve: 0.75). Higher PCS severity scores correlated with lower AVR (R = − 0.37 p = 0.017). The association of microvascular changes with PCS severity were amplified in PCS patients exhibiting higher levels of inflammatory parameters.
Conclusion
Our results demonstrate that prolonged endothelial dysfunction is a hallmark of PCS, and impairments of the microcirculation seem to explain ongoing symptoms in patients. As potential therapies for PCS emerge, RVA parameters may become relevant as clinical biomarkers for diagnosis and therapy management.
Background
True date palms (Phoenix dactylifera L.) are impressive trees and have served as an indispensable source of food for mankind in tropical and subtropical countries for centuries. The aim of this study is to differentiate date palm tree varieties by analysing leaflet cross sections with technical/optical methods and artificial neural networks (ANN).
Results
Fluorescence microscopy images of leaflet cross sections have been taken from a set of five date palm tree cultivars (Hewlat al Jouf, Khlas, Nabot Soltan, Shishi, Um Raheem). After features extraction from images, the obtained data have been fed in a multilayer perceptron ANN with backpropagation learning algorithm.
Conclusions
Overall, an accurate result in prediction and differentiation of date palm tree cultivars was achieved with average prediction in tenfold cross-validation is 89.1% and reached 100% in one of the best ANN.
Picosecond dynamics in haemoglobin from different species: A quasielastic neutron scattering study
(2014)
Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data.
The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses.