Refine
Year of publication
- 2024 (7)
- 2023 (7)
- 2022 (28)
- 2021 (28)
- 2020 (32)
- 2019 (39)
- 2018 (33)
- 2017 (31)
- 2016 (26)
- 2015 (28)
- 2014 (18)
- 2013 (22)
- 2012 (23)
- 2011 (21)
- 2010 (31)
- 2009 (29)
- 2008 (29)
- 2007 (24)
- 2006 (17)
- 2005 (21)
- 2004 (24)
- 2003 (15)
- 2002 (9)
- 2001 (3)
- 2000 (8)
- 1999 (6)
- 1998 (7)
- 1997 (5)
- 1996 (4)
- 1995 (3)
- 1994 (3)
- 1993 (4)
- 1992 (1)
- 1990 (1)
- 1989 (2)
- 1988 (4)
- 1987 (2)
- 1986 (1)
- 1985 (1)
- 1980 (2)
Institute
- IfB - Institut für Bioengineering (540)
- Fachbereich Medizintechnik und Technomathematik (451)
- Fachbereich Luft- und Raumfahrttechnik (135)
- Fachbereich Chemie und Biotechnologie (11)
- Kommission für Forschung und Entwicklung (5)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Maschinenbau und Mechatronik (1)
- Senat (1)
Has Fulltext
- no (599) (remove)
Language
- English (599) (remove)
Document Type
- Article (436)
- Conference Proceeding (108)
- Part of a Book (34)
- Book (9)
- Other (4)
- Patent (4)
- Doctoral Thesis (3)
- Talk (1)
Keywords
- solar sail (5)
- CellDrum (3)
- GOSSAMER-1 (3)
- MASCOT (3)
- Biocomposites (2)
- Iterative learning control (2)
- Limit analysis (2)
- Mars (2)
- Natural fibres (2)
- Polymer-matrix composites (2)
Limit loads of circumferentially flawed pipes and cylindrical vessels under internal pressure
(2006)
In this paper we propose a stochastic programming method to analyse limit and shakedown of structures under uncertainty condition of strength. Based on the duality theory, the shakedown load multiplier formulated by the kinematic theorem is proved actually to be the dual form of the shakedown load multiplier formulated by static theorem. In this investigation a dual chance constrained programming algorithm is developed to calculate simultaneously both the upper and lower bounds of the plastic collapse limit and the shakedown limit. The edge-based smoothed finite element method (ES-FEM) with three-node linear triangular elements is used for structural analysis.
The vaginal prolapse after hysterectomy (removal of the uterus) is often associated with the prolapse of the vaginal vault, rectum, bladder, urethra or small bowel. Minimally
invasive surgery such as laparoscopic sacrocolpopexy and pectopexy are widely performed for the treatment of the vaginal prolapse with weakly supported vaginal vault after hysterectomy using prosthetic mesh implants to support (or strengthen) lax apical ligaments. Implants of different shape, size and polymers are selected depending on the patient’s anatomy and the surgeon’s preference. In this computational study on pectopexy, DynaMesh®-PRP soft, GYNECARE GYNEMESH® PS Nonabsorbable PROLENE® soft and Ultrapro® are tested in a 3D finite element model of the female pelvic floor. The mesh model is implanted into the extraperitoneal space and sutured to the vaginal stump with a bilateral fixation to the iliopectineal ligament at both sides. Numerical simulations are conducted at rest, after surgery and during Valsalva maneuver with weakened tissues modeled by reduced tissue stiffness. Tissues and prosthetic meshes are modeled as incompressible, isotropic hyperelastic materials. The positions of the organs are calculated with respect to the pubococcygeal line (PCL) for female pelvic floor at rest, after repair and during Valsalva maneuver using the three meshes.
Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study
(2020)
Purpose
Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state.
Methods
Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow.
Results
With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique.
Conclusions
Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon.
Clinical relevance
Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques.