Refine
Year of publication
Institute
- IfB - Institut für Bioengineering (661)
- Fachbereich Medizintechnik und Technomathematik (629)
- Fachbereich Luft- und Raumfahrttechnik (145)
- Fachbereich Chemie und Biotechnologie (13)
- Kommission für Forschung und Entwicklung (5)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Gestaltung (1)
- Fachbereich Maschinenbau und Mechatronik (1)
- Senat (1)
Language
- English (671)
- German (102)
- Russian (13)
- Multiple languages (2)
Document Type
- Article (535)
- Conference Proceeding (162)
- Part of a Book (36)
- Book (14)
- Report (12)
- Patent (9)
- Doctoral Thesis (8)
- Other (4)
- Habilitation (3)
- Lecture (3)
Keywords
- Finite-Elemente-Methode (16)
- Einspielen <Werkstoff> (13)
- shakedown analysis (9)
- FEM (6)
- Limit analysis (6)
- Shakedown analysis (6)
- limit analysis (6)
- Clusterion (5)
- solar sail (5)
- Air purification (4)
- Einspielanalyse (4)
- Hämoglobin (4)
- Lipopolysaccharide (4)
- Luftreiniger (4)
- Plasmacluster ion technology (4)
- Raumluft (4)
- Shakedown (4)
- Sonde (4)
- Technische Mechanik (4)
- Traglast (4)
- Traglastanalyse (4)
- shakedown (4)
- CellDrum (3)
- Eisschicht (3)
- GOSSAMER-1 (3)
- Kohlenstofffaser (3)
- MASCOT (3)
- lipopolysaccharides (3)
- ratchetting (3)
- Analytischer Zulaessigkeitsnachweis (2)
- Biocomposites (2)
- Bruchmechanik (2)
- Druckbeanspruchung (2)
- Druckbehälter (2)
- Druckbelastung (2)
- Einspiel-Analyse (2)
- Erythrozyt (2)
- Fehlerstellen (2)
- Fibroblast (2)
- Iterative learning control (2)
- Mars (2)
- Natural fibres (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- Polymer-matrix composites (2)
- Ratcheting (2)
- Rohr (2)
- Rohrbruch (2)
- Solar sail (2)
- Spacecraft (2)
- Stahl (2)
- Stickstoffmonoxid (2)
- Stiffness (2)
- Stress concentrations (2)
- Trajectory Optimization (2)
- bacterial cellulose (2)
- biopotential electrodes (2)
- burst pressure (2)
- burst tests (2)
- carbonized rice husk (2)
- celldrum technology (2)
- damage (2)
- flaw (2)
- limit load (2)
- load limit (2)
- locomotion (2)
- multiple NEA rendezvous (2)
- muscle fascicle behavior (2)
- nanostructured carbonized plant parts (2)
- nanostrukturierte carbonisierte Pflanzenteile (2)
- nitric oxide gas (2)
- pipes (2)
- plant scanner (2)
- prebiotic (2)
- small spacecraft (2)
- tension–torsion loading (2)
- ultrasound (2)
- ultrasound imaging (2)
- vessels (2)
- Achilles tendon (1)
- Adaptive control (1)
- Adsorption (1)
- Ageing (1)
- AlterG (1)
- Alternating plasticity (1)
- Alzheimer's disease (1)
- Analogue Environments (1)
- Analysis (1)
- Anastomose (1)
- Anastomosis (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Antarctic Glaciology (1)
- Antarctica (1)
- Architectural gear ratio (1)
- Arthosetherapie (1)
- Assistive technology (1)
- Asteroid Deflection (1)
- Attitude dynamics (1)
- Aufschlagversuch (1)
- Autofluoreszenzverfahren (1)
- Autolysis (1)
- Automated Optimization (1)
- Automatic control (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Bacillus sp (1)
- Bacterial cellulose (1)
- Bakterien (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bein (1)
- Bicharakteristikenverfahren (1)
- Biomechanical simulation (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Bioreaktor (1)
- Biosolubilization (1)
- Bladder (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- Bone sawing (1)
- Carbon sources (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Cell permeability (1)
- Cellular force (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Cementoblast (1)
- Chance constrained programming (1)
- Circular Dichroism (1)
- Coefficient of ocular rigidity (1)
- Collagen fibrils (1)
- Compression (1)
- Computational biomechanics (1)
- Connective tissues (1)
- Constitutive model (1)
- Contractile tension (1)
- Convex optimization (1)
- Corneo-scleral shell (1)
- Cost-effectiveness (1)
- Cryobot (1)
- Culture media (1)
- DLR-ESTEC GOSSAMER roadmap for solar sailing (1)
- Damage mechanics theory (1)
- Dattel (1)
- Decomposition (1)
- Deformation (1)
- Dekontamination (1)
- Design-by-analysis (1)
- Differential tonometry (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Distorsion des oberen Sprunggelenks (1)
- Druckgeräte (1)
- Drug simulation (1)
- Dry surfaces (1)
- EEG (1)
- ELISA (1)
- ES-FEM (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elastodynamik (1)
- Elastostatics (1)
- Electromechanical modeling (1)
- Elektrodynamik (1)
- Elektromyographie (1)
- Elektrostimulation (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Endothelzelle (1)
- Environmental impact (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Evolution of damage (1)
- Evolutionary Neurocontrol (1)
- Exact Ilyushin yield surface (1)
- Experiment (1)
- Extension fracture (1)
- Extension strain criterion (1)
- Extensor (1)
- External knee adduction moments (1)
- Extracellular matrix (ECM) (1)
- Extraterrestrial Glaciology (1)
- Eyeball (1)
- FEM-Programm (1)
- FEM-computation (1)
- FGF23 (1)
- FS-FEM (1)
- Festkörper (1)
- Finite element analysis (1)
- Finite element analysis (FEA) (1)
- Finite element method (1)
- Finite element modelling (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fließgrenze (1)
- Force (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Fußball (1)
- Geriatric (1)
- Glaciological instruments and methods (1)
- Glaucoma (1)
- Global and local collapse (1)
- Gonarthrose (1)
- Gossamer (1)
- Gossamer structures (1)
- Grenzwertberechnung (1)
- Growth modelling (1)
- Haemodialysis (1)
- Handbike (1)
- Harnleiter (1)
- Heart tissue culture (1)
- Hemoglobin structure (1)
- Hip fractures (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Human-Computer interaction (1)
- Hybrid Propellants (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hämoglobinstruktur (1)
- Ice Melting (1)
- Ice melting probe (1)
- Ice penetration (1)
- Icy Moons (1)
- Icy moons (1)
- Impedance Spectroscopy (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Interplanetary flight (1)
- Interstellar objects (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ion channels (1)
- Jupiter (1)
- Kinematics (1)
- Kinetics (1)
- Klotho (1)
- Knee (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Körpertemperatur (1)
- LISA (1)
- LPS (1)
- Lactobacillus rhamnosus GG (1)
- Lichtstreuungsbasierte Instrumente (1)
- Liver (1)
- Load modeling (1)
- Long COVID (1)
- Low-Thrust Propulsion (1)
- MBST (1)
- Machine learning (1)
- Manipulated variables (1)
- Materialermüdung (1)
- Mechanical simulation (1)
- Mechanical stability (1)
- Mechanics (1)
- Mechanische Beanspruchung (1)
- Mechanotransduction (1)
- Medusomyces gisevi (1)
- Melting Efficiency (1)
- Melting Performance (1)
- Melting Probe (1)
- Microbial adhesion (1)
- Microcirculation (1)
- Mild cognitive impairment (1)
- Missions (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Multimode failure (1)
- Multiphase (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Muscle fibers (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Natriumhypochlorit (1)
- Neuromuskuläres System (1)
- Niacin (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-linear optimization (1)
- Non-parallel fissures (1)
- Nucleus Pulposus (1)
- Ocean Worlds (1)
- Ocean worlds (1)
- Ocular blood flow (1)
- Orbital dynamics (1)
- Organkultur (1)
- Osteoporose (1)
- Osteoporosis (1)
- PFM (1)
- PHILAE (1)
- PTH (1)
- Paralympic sport (1)
- Passive stretching (1)
- Pelvic floor dysfunction (1)
- Pelvic muscle (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenstress (1)
- Pharmacology (1)
- Phosphate (1)
- Physiology (1)
- Planetary Protection (1)
- Planetary exploration (1)
- Plastizität (1)
- Post-COVID-19 syndrome (1)
- Pressure loaded crack-face (1)
- Pressure-volume relationship (1)
- Prevention (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proteine (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- RVA (1)
- Random variable (1)
- Ratchetting (1)
- Raumfahrt (1)
- Recombinant activated protein C (1)
- Reconstruction (1)
- Red blood cell storage (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Rehabilitationsmedizin (1)
- Rehabilitatives Training (1)
- Reliability analysis (1)
- Reliability of structures (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Reusable Rocket Engines (1)
- Riboflavin (1)
- Robotic rehabilitation (1)
- Robotik (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- Sampling methods (1)
- Schienbeinschoner (1)
- Schwammknochen (1)
- Sensitivity (1)
- Sepsis (1)
- Septic cardiomyopathy (1)
- Sequence-Search (1)
- Shakedown criterion (1)
- Simulation (1)
- Skeletal muscle (1)
- Sleep EEG (1)
- Small Aral Sea (1)
- Small Solar System Body Lander (1)
- Small Spacecraft (1)
- Small spacecraft (1)
- Solar Power Sail (1)
- Solar Sail (1)
- Spacecraft Trajectory Optimization (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Statics (1)
- Stochastic programming (1)
- Strukturanalyse (1)
- Subclacial exploration (1)
- Subglacial lakes (1)
- SunRav BookEditor (1)
- Surface microorganisms (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Swabbing (1)
- Tapered ends (1)
- Temperaturabhängigkeit (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tendons (1)
- Tension (1)
- Thiamine (1)
- Tissue Engineering (1)
- Torsion (1)
- Torsionsbelastung (1)
- Tragfähigkeit (1)
- Training (1)
- Trainingsgerät (1)
- Trajectories (1)
- Ultrasound (1)
- Uniaxial compression test (1)
- Ureter (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Visual field asymmetry (1)
- Vitamin A (1)
- Vitamin B (1)
- Vitamin D (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- Zug-Druck Belastung (1)
- Zug-Druck-Beanspruchung (1)
- Zug-Druck-Belastung (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- activated nanostructured carbon (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- alternierend Verformbarkeit (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- aortic perfusion (1)
- aromatic amines (1)
- arthrosis therapy (1)
- asteroid lander (1)
- asteroid sample return (1)
- attitude dynamics (1)
- autofluorescence-based detection system (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- biofilms (1)
- biomechanics (1)
- bone density (1)
- bone structure (1)
- cancellous bone (1)
- cardiomyocyte biomechanics (1)
- cell aerosolization (1)
- cell atomization (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- coculture (1)
- cognitive impairment (1)
- community dwelling (1)
- computational fluid dynamics analysis (1)
- connective tissue (1)
- constitutive modeling (1)
- constructive alignment (1)
- contractile tension (1)
- correlation (1)
- crop yield (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- dental trauma (1)
- design-by-analysis (1)
- dialysis (1)
- difficult airway (1)
- direct method (1)
- distance learning (1)
- distorted element (1)
- double-lumen tube intubation (1)
- drop jump (1)
- e-books (1)
- e-issues (1)
- ecological structure (1)
- elastic solids (1)
- electromyography (1)
- endoluminal (1)
- energy absorption (1)
- energy dissipation (1)
- epithelization (1)
- examination (1)
- exopolysaccharides (1)
- extracorporeal membrane oxygenation (1)
- fatigue analyses (1)
- fibulare Bandruptur (1)
- finite element analysis (1)
- flotilla missions (1)
- force generation (1)
- forehead EEG (1)
- fortschreitende plastische Deformation (1)
- gait (1)
- gonarthrosis (1)
- habitability (1)
- healthy aging (1)
- heliosphere (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- human dermal fibroblasts (1)
- humic acid (1)
- hydrogel (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- ice moons (1)
- icy moons (1)
- immobilization (1)
- impedance spectroscopy (1)
- in-ear EEG (1)
- intraclass correlation coefficient (1)
- ion propulsion (1)
- kontraktile Spannung (1)
- konvexe Optimierung (1)
- life detection (1)
- light scattering analysis (1)
- lignite (1)
- limit and shakedown analysis (1)
- linear kinematic hardening (1)
- lipopolysaccharide (1)
- load carrying capacity (1)
- long-term retention (1)
- low-rank coal (1)
- low-thrust (1)
- low-thrust trajectory optimization (1)
- lower bound theorem (1)
- material shakedown (1)
- mechanical buffer (1)
- mechanical waves (1)
- metagenomics (1)
- microbial diversity (1)
- multimodal (1)
- muscle mechanics (1)
- naphtols (1)
- near-Earth asteroid (1)
- non-simplex S-FEM elements (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- orbit control (1)
- orbital dynamics (1)
- overload (1)
- parabolic flight (1)
- performance testing (1)
- phenols (1)
- physiology (1)
- planetary defence (1)
- plant stress (1)
- plasma generated ions (1)
- plastic deformation (1)
- practical learning (1)
- prevention (1)
- probabilistic fracture mechanics (1)
- protein (1)
- psychosocial (1)
- pullulan (1)
- rehabilitation (1)
- reliability (1)
- reliability analysis (1)
- reliability of structures (1)
- responsive space (1)
- retinal microvasculature (1)
- retinal vessels (1)
- rhAPC (1)
- running (1)
- rupture of the fibular ligament (1)
- sEMG (1)
- sailcraft (1)
- sample return (1)
- sarcomere operating length (1)
- second-order reliability method (1)
- sensors (1)
- series elastic element behavior (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- shoulder (1)
- simulation (1)
- small solar system body characterisation (1)
- small spacecraft asteroid lander (1)
- small spacecraft solar sail (1)
- smooth muscle contraction (1)
- softs (1)
- soil amendment (1)
- soil health (1)
- soil remediation (1)
- solar sails (1)
- solar system (1)
- space missions (1)
- sprint start (1)
- standard error of measurement (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- subglacial aquatic ecosystems (1)
- subsurface ice (1)
- subsurface ice research (1)
- subsurface probe (1)
- surface modification (1)
- survival (1)
- system engineering (1)
- tendon rupture (1)
- test-retest reliability (1)
- thermal ratcheting (1)
- training simulator (1)
- tri-lineage differentiation (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- underwater vehicle (1)
- unloading (1)
- videolaryngoscopy (1)
- virgin passive (1)
- virtual reality (1)
- viscoelasticity (1)
- walking (1)
- walking gait (1)
- water bridge phenomenon (1)
- wound healing (1)
- yield stress (1)
A procedure for the evaluation of the failure probability of elastic-plastic thin shell structures is presented. The procedure involves a deterministic limit and shakedown analysis for each probabilistic iteration which is based on the kinematical approach and the use the exact Ilyushin yield surface. Based on a direct definition of the limit state function, the non-linear problems may be efficiently solved by using the First and Second Order Reliabiblity Methods (Form/SORM). This direct approach reduces considerably the necessary knowledge of uncertain technological input data, computing costs and the numerical error. In: Computational plasticity / ed. by Eugenio Onate. Dordrecht: Springer 2007. VII, 265 S. (Computational Methods in Applied Sciences ; 7) (COMPLAS IX. Part 1 . International Center for Numerical Methods in Engineering (CIMNE)). ISBN 978-1-402-06576-7 S. 186-189
Abstracts of the ACHEMA 2000 - International Meeting on Chemical Engineering, Environmental Protection and Biotechnology, May 22 - 27, 2000. Frankfurt am Main. Achema 2000 : special edition / Linde. [Ed.: Linde AG. Red.: Volker R. Leski]. - Wiesbaden : Linde AG, 2000. - 56 p. : Ill., . - pp: 79 - 81
The structural reliability with respect to plastic collapse or to inadaptation is formulated on the basis of the lower bound limit and shakedown theorems. A direct definition of the limit state function is achieved which permits the use of the highly effective first order reliability methods (FORM) is achieved. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis. The limit state function and its gradient are obtained from a mathematical optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error, leading to highly effective and precise reliability analyses.
This work is an attempt to answer the question: How to use convex programming in shakedown analysis of structures made of materials with temperature-dependent properties. Based on recently established shakedown theorems and formulations, a dual relationship between upper and lower bounds of the shakedown limit load is found, an algorithmfor shakedown analysis is proposed. While the original problem is neither convex nor concave, the algorithm presented here has the advantage of employing convex programming tools.
In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demonstrated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several additional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings.
Fatigue analyses are conducted with the aim of verifying that thermal ratcheting is limited. To this end it is important to make a clear distintion between the shakedown range and the ratcheting range (continuing deformation). As part of an EU-supported research project, experiments were carried out using a 4-bar model. The experiment comprised a water-cooled internal tube, and three insulated heatable outer test bars. The system was subjected to alternating axial forces, superimposed with alternating temperatures at the outer bars. The test parameters were partly selected on the basis of previous shakedown analyses. During the test, temperatures and strains were measured as a function of time. The loads and the resulting stresses were confirmed on an ongoing basis during performance of the test, and after it. Different material models were applied for this incremental elasto-plastic analysis using the ANSYS program. The results of the simulation are used to verify the FEM-based shakedown analysis.
Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions.
In the new European standard for unfired pressure vessels, EN 13445-3, there are two approaches for carrying out a Design-by-Analysis that cover both the stress categorization method (Annex C) and the direct route method (Annex B) for a check against global plastic deformation and against progressive plastic deformation. This paper presents the direct route in the language of limit and shakedown analysis. This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for mechanical and thermal actions. One observation from the examples is that the so-called 3f (3Sm) criterion fails to be a reliable check against progressive plastic deformation. Precise conditions are given, which greatly restrict the applicability of the 3f criterion.
Structural design analyses are conducted with the aim of verifying the exclusion of ratchetting. To this end it is important to make a clear distinction between the shakedown range and the ratchetting range. The performed experiment comprised a hollow tension specimen which was subjected to alternating axial forces, superimposed with constant moments. First, a series of uniaxial tests has been carried out in order to calibrate a bounded kinematic hardening rule. The load parameters have been selected on the basis of previous shakedown analyses with the PERMAS code using a kinematic hardening material model. It is shown that this shakedown analysis gives reasonable agreement between the experimental and the numerical results. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis.
Limit and shakedown analysis are effective methods for assessing the load carrying capacity of a given structure. The elasto–plastic behavior of the structure subjected to loads varying in a given load domain is characterized by the shakedown load factor, defined as the maximum factor which satisfies the sufficient conditions stated in the corresponding static shakedown theorem. The finite element dicretization of the problem may lead to very large convex optimization. For the effective solution a basis reduction method has been developed that makes use of the special problem structure for perfectly plastic material. The paper proposes a modified basis reduction method for direct application to the two-surface plasticity model of bounded kinematic hardening material. The considered numerical examples show an enlargement of the load carrying capacity due to bounded hardening.
This paper presents the direct route to Design by Analysis (DBA) of the new European pressure vessel standard in the language of limit and shakedown analysis (LISA). This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for some examples from the DBA-Manual. One observation from the examples is, that the optimisation approach gives reliable and close lower bound solutions leading to simple and optimised design decision.
The load-carrying capacity or the safety against plastic limit states are the central questions in the design of structures and passive components in the apparatus engineering. A precise answer is most simply given by limit and shakedown analysis. These methods can be based on static and kinematic theorems for lower and upper bound analysis. Both may be formulated as optimization problems for finite element discretizations of structures. The problems of large-scale analysis and the extension towards realistic material modelling will be solved in a European research project. Limit and shakedown analyses are briefly demonstrated with illustrative examples.
Shock waves, explosions, impacts or cavitation bubble collapses may generate stress waves in solids causing cracks or unexpected dammage due to focussing, physical nonlinearity or interaction with existing cracks. There is a growing interest in wave propagation, which poses many novel problems to experimentalists and theorists.
Summary: This paper presents a methodology to study and understand the mechanics of stapled anastomotic behaviors by combining empirical experimentation and finite element analysis. Performance of stapled anastomosis is studied in terms of leakage and numerical results which are compared to in vitro experiments performed on fresh porcine tissue. Results suggest that leaks occur between the tissue and staple legs penetrating through the tissue.
Originalausgabe: Orthopädische Praxis Jg. 47. 2011 H. 11; S. 536-543. Mit freundlicher Genehmigung des Verlags Zusammenfassung: Auf der Basis von Patientenabfragen mittels Fragebogen zum Schmerzempfinden und zur Einschränkung bei Aktivitäten des alltäglichen Lebens wird die Langzeitwirkung der MBST® KernspinResonanz-Therapie bei Gonarthrose untersucht. An der Studie nahmen 39 Patienten teil, bei denen die Therapie bis zu vier Jahre zurückliegt. Neben einer Gesamtbetrachtung wird der Erfolg auch in Abhängigkeit von Alter, Geschlecht und sportlicher Aktivität analysiert. Insgesamt weist die Studie auf eine anhaltende Verbesserung des Gesundheitszustands mit zum Teil deutlicher Schmerzlinderung auch noch nach vier Jahren hin, jedoch mit einer leichten Schmerzzunahme gegen Ende des Untersuchungszeitraums von vier Jahren. Eine tendenziell positivere Wirkung bei Frauen, älteren Menschen oder auch sportlich nicht-aktiven Patienten lässt auf eine mögliche Beeinflussung des Erfolgs der Therapie durch (Über-)Belastung im Alltag schließen. Ein zusätzlich positiver Effekt der Therapie auf die Knochendichte ist ebenfalls denkbar, dies bleibt jedoch offen.
Diese Studie beschäftigte sich mit der Dämpfungswirkung von Schienbeinschonern, wie sie beim Fußball zum Einsatz kommen. Sie wurde mit Hilfe eines Pendelhammers durchgeführt, der verschiedene Aufschlagkräfte auf die Schoner ermöglichte. Dabei wurde deutlich, dass Schienbeinschoner die beste Wirkung bei Maximalkräften unterhalb von 5kN erreichen können, dass bei größerer Belastung allerdings Verbesserungsbedarf besteht. Hierfür konnte, u.a. durch den Einsatz neuer Materialien, ein guter Ansatzpunkt im „adäquaten Zusammenspiel von Schale und Polsterung“ der Schoner gefunden werden. Die Untersuchung hat weiterhin gezeigt, dass zumindest teilweise eine deutliche Verbesserung der Dämpfungswirkung der Schienbeinschoner in den letzten Jahren erreicht werden konnte.