Refine
Year of publication
- 2024 (7)
- 2023 (7)
- 2022 (28)
- 2021 (28)
- 2020 (32)
- 2019 (39)
- 2018 (33)
- 2017 (31)
- 2016 (26)
- 2015 (28)
- 2014 (18)
- 2013 (22)
- 2012 (23)
- 2011 (21)
- 2010 (31)
- 2009 (29)
- 2008 (29)
- 2007 (24)
- 2006 (17)
- 2005 (21)
- 2004 (24)
- 2003 (15)
- 2002 (9)
- 2001 (3)
- 2000 (8)
- 1999 (6)
- 1998 (7)
- 1997 (5)
- 1996 (4)
- 1995 (3)
- 1994 (3)
- 1993 (4)
- 1992 (1)
- 1990 (1)
- 1989 (2)
- 1988 (4)
- 1987 (2)
- 1986 (1)
- 1985 (1)
- 1980 (2)
Institute
- IfB - Institut für Bioengineering (540)
- Fachbereich Medizintechnik und Technomathematik (451)
- Fachbereich Luft- und Raumfahrttechnik (135)
- Fachbereich Chemie und Biotechnologie (11)
- Kommission für Forschung und Entwicklung (5)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Maschinenbau und Mechatronik (1)
- Senat (1)
Has Fulltext
- no (599) (remove)
Language
- English (599) (remove)
Document Type
- Article (436)
- Conference Proceeding (108)
- Part of a Book (34)
- Book (9)
- Other (4)
- Patent (4)
- Doctoral Thesis (3)
- Talk (1)
Keywords
- solar sail (5)
- CellDrum (3)
- GOSSAMER-1 (3)
- MASCOT (3)
- Biocomposites (2)
- Iterative learning control (2)
- Limit analysis (2)
- Mars (2)
- Natural fibres (2)
- Polymer-matrix composites (2)
Replacement tissues, designed to fill in articular cartilage defects, should exhibit the same properties as the native material. The aim of this study is to foster the understanding of, firstly, the mechanical behavior of the material itself and, secondly, the influence of cultivation parameters on cell seeded implants as well as on cell migration into acellular implants. In this study, acellular cartilage replacement material is theoretically, numerically and experimentally investigated regarding its viscoelastic properties, where a phenomenological model for practical applications is developed. Furthermore, remodeling and cell migration are investigated.
There is significant interest in sampling subglacial environments for geobiological studies, but they are difficult to access. Existing ice-drilling technologies make it cumbersome to maintain microbiologically clean access for sample acquisition and environmental stewardship of potentially fragile subglacial aquatic ecosystems. The IceMole is a maneuverable subsurface ice probe for clean in situ analysis and sampling of glacial ice and subglacial materials. The design is based on the novel concept of combining melting and mechanical propulsion. It can change melting direction by differential heating of the melting head and optional side-wall heaters. The first two prototypes were successfully tested between 2010 and 2012 on glaciers in Switzerland and Iceland. They demonstrated downward, horizontal and upward melting, as well as curve driving and dirt layer penetration. A more advanced probe is currently under development as part of the Enceladus Explorer (EnEx) project. It offers systems for obstacle avoidance, target detection, and navigation in ice. For the EnEx-IceMole, we will pay particular attention to clean protocols for the sampling of subglacial materials for biogeochemical analysis. We plan to use this probe for clean access into a unique subglacial aquatic environment at Blood Falls, Antarctica, with return of a subglacial brine sample.
Thermodynamic stability, configurational motions and internal forces of haemoglobin (Hb) of three endotherms (platypus, Ornithorhynchus anatinus; domestic chicken, Gallus gallus domesticus and human, Homo sapiens) and an ectotherm (salt water crocodile, Crocodylus porosus) were investigated using circular dichroism, incoherent elastic neutron scattering and coarse-grained Brownian dynamics simulations. The experimental results from Hb solutions revealed a direct correlation between protein resilience, melting temperature and average body temperature of the different species on the 0.1 ns time scale. Molecular forces appeared to be adapted to permit conformational fluctuations with a root mean square displacement close to 1.2 Å at the corresponding average body temperature of the endotherms. Strong forces within crocodile Hb maintain the amplitudes of motion within a narrow limit over the entire temperature range in which the animal lives. In fully hydrated powder samples of human and chicken, Hb mean square displacements and effective force constants on the 1 ns time scale showed no differences over the whole temperature range from 10 to 300 K, in contrast to the solution case. A complementary result of the study, therefore, is that one hydration layer is not sufficient to activate all conformational fluctuations of Hb in the pico- to nanosecond time scale which might be relevant for biological function. Coarse-grained Brownian dynamics simulations permitted to explore residue-specific effects. They indicated that temperature sensing of human and chicken Hb occurs mainly at residues lining internal cavities in the β-subunits.