Refine
Year of publication
Document Type
- Article (5586) (remove)
Language
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- Blitzschutz (3)
- CellDrum (3)
- Heparin (3)
- Label-free detection (3)
- additive manufacturing (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
Institute
- Fachbereich Medizintechnik und Technomathematik (1578)
- Fachbereich Wirtschaftswissenschaften (687)
- Fachbereich Elektrotechnik und Informationstechnik (625)
- Fachbereich Energietechnik (608)
- Fachbereich Chemie und Biotechnologie (597)
- INB - Institut für Nano- und Biotechnologien (540)
- Fachbereich Maschinenbau und Mechatronik (483)
- IfB - Institut für Bioengineering (448)
- Fachbereich Luft- und Raumfahrttechnik (373)
- Fachbereich Bauingenieurwesen (330)
- Solar-Institut Jülich (107)
- Fachbereich Architektur (79)
- Fachbereich Gestaltung (58)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (42)
- ECSM European Center for Sustainable Mobility (39)
- Nowum-Energy (34)
- Sonstiges (23)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (18)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (16)
A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes.