Refine
Year of publication
- 2021 (102) (remove)
Document Type
- Article (102) (remove)
Keywords
- Principal component analysis (2)
- capacitive field-effect sensor (2)
- constructive alignment (2)
- examination (2)
- harmonic radar (2)
- long-term retention (2)
- multimodal (2)
- practical learning (2)
- Aircraft sizing (1)
- AlterG (1)
- Authenticity (1)
- Bacillus sp (1)
- Bemessung (1)
- Biosolubilization (1)
- Bloom’s Taxonomy (1)
- Bone quality and biomechanics (1)
- Bootstrap (1)
- CFD (1)
- Capacitive field-effect sensor (1)
- CellDrum (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (38)
- IfB - Institut für Bioengineering (27)
- INB - Institut für Nano- und Biotechnologien (15)
- Fachbereich Wirtschaftswissenschaften (13)
- Fachbereich Chemie und Biotechnologie (11)
- Fachbereich Luft- und Raumfahrttechnik (11)
- Fachbereich Energietechnik (7)
- Fachbereich Bauingenieurwesen (6)
- Fachbereich Elektrotechnik und Informationstechnik (5)
- Fachbereich Maschinenbau und Mechatronik (4)
- Solar-Institut Jülich (4)
- ECSM European Center for Sustainable Mobility (2)
- Fachbereich Architektur (2)
- IBB - Institut für Baustoffe und Baukonstruktionen (2)
- IMP - Institut für Mikrowellen- und Plasmatechnik (2)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (2)
- Nowum-Energy (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
Dual frequency magnetic excitation of magnetic nanoparticles (MNP) enables enhanced biosensing applications. This was studied from an experimental and theoretical perspective: nonlinear sum-frequency components of MNP exposed to dual-frequency magnetic excitation were measured as a function of static magnetic offset field. The Langevin model in thermodynamic equilibrium was fitted to the experimental data to derive parameters of the lognormal core size distribution. These parameters were subsequently used as inputs for micromagnetic Monte-Carlo (MC)-simulations. From the hysteresis loops obtained from MC-simulations, sum-frequency components were numerically demodulated and compared with both experiment and Langevin model predictions. From the latter, we derived that approximately 90% of the frequency mixing magnetic response signal is generated by the largest 10% of MNP. We therefore suggest that small particles do not contribute to the frequency mixing signal, which is supported by MC-simulation results. Both theoretical approaches describe the experimental signal shapes well, but with notable differences between experiment and micromagnetic simulations. These deviations could result from Brownian relaxations which are, albeit experimentally inhibited, included in MC-simulation, or (yet unconsidered) cluster-effects of MNP, or inaccurately derived input for MC-simulations, because the largest particles dominate the experimental signal but concurrently do not fulfill the precondition of thermodynamic equilibrium required by Langevin theory.
Contractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity
(2021)
Vigorous exercise countermeasures in microgravity can largely attenuate muscular degeneration, albeit the extent of applied loading is key for the extent of muscle wasting. Running on the International Space Station is usually performed with maximum loads of 70% body weight (0.7 g). However, it has not been investigated how the reduced musculoskeletal loading affects muscle and series elastic element dynamics, and thereby force and power generation. Therefore, this study examined the effects of running on the vertical treadmill facility, a ground-based analog, at simulated 0.7 g on gastrocnemius medialis contractile behavior. The results reveal that fascicle−series elastic element behavior differs between simulated hypogravity and 1 g running. Whilst shorter peak series elastic element lengths at simulated 0.7 g appear to be the result of lower muscular and gravitational forces acting on it, increased fascicle lengths and decreased velocities could not be anticipated, but may inform the development of optimized running training in hypogravity. However, whether the alterations in contractile behavior precipitate musculoskeletal degeneration warrants further study.
Plant viruses are major contributors to crop losses and induce high economic costs worldwide. For reliable, on-site and early detection of plant viral diseases, portable biosensors are of great interest. In this study, a field-effect SiO2-gate electrolyte-insulator-semiconductor (EIS) sensor was utilized for the label-free electrostatic detection of tobacco mosaic virus (TMV) particles as a model plant pathogen. The capacitive EIS sensor has been characterized regarding its TMV sensitivity by means of constant-capacitance method. The EIS sensor was able to detect biotinylated TMV particles from a solution with a TMV concentration as low as 0.025 nM. A good correlation between the registered EIS sensor signal and the density of adsorbed TMV particles assessed from scanning electron microscopy images of the SiO2-gate chip surface was observed. Additionally, the isoelectric point of the biotinylated TMV particles was determined via zeta potential measurements and the influence of ionic strength of the measurement solution on the TMV-modified EIS sensor signal has been studied.
Glucose oxidase (GOx) is an enzyme frequently used in glucose biosensors. As increased temperatures can enhance the performance of electrochemical sensors, we investigated the impact of temperature pulses on GOx that was drop-coated on flattened Pt microwires. The wires were heated by an alternating current. The sensitivity towards glucose and the temperature stability of GOx was investigated by amperometry. An up to 22-fold increase of sensitivity was observed. Spatially resolved enzyme activity changes were investigated via scanning electrochemical microscopy. The application of short (<100 ms) heat pulses was associated with less thermal inactivation of the immobilized GOx than long-term heating.
Der arbeitsrechtlich richtige Umgang mit Zeiten einer Dienstreise kann in der betrieblichen Praxis Probleme bereiten. Ob die Reisezeiten als solche Arbeitszeit i. S. des Arbeitszeitgesetzes (ArbZG ) darstellen, also bspw. auf die tägliche Höchstarbeitszeit angerechnet werden müssen oder nicht, ist oftmals genauso unklar wie die Frage, ob und inwieweit Reisezeiten vergütungspflichtig sind. Aber auch, ob ein Arbeitnehmer überhaupt zur Durchführung einer Dienstreise verpflichtet werden kann, ist ein möglicher Anlass von Streitigkeiten zwischen den Arbeitsvertragsparteien, wie verschiedene Gerichtsentscheidungen zeigen. Der nachfolgende Beitrag beantwortet die aufgeworfenen Fragen und gibt hierzu einen praxisorientierten Überblick.
Die Arbeitswelt ist im Umbruch. Der Bedarf an flexiblen Arbeitszeitmodellen nimmt stetig zu, wobei die Corona-Pandemie dieses Bedürfnis nochmals verschärft hat. Gerade auch in kleineren und mittleren Unternehmen wächst die Notwendigkeit, den Einsatz der Beschäftigten möglichst bedarfsgerecht zu steuern, also bei guter Auftragslage mehr Arbeitszeit abzurufen und bei ausbleibenden Aufträgen die Arbeitszeit zu reduzieren und somit bezahlte „Leerlaufzeiten“ zu vermeiden. Der Gesetzgeber stellt den Arbeitgebern hierfür das Instrument der sog. Abrufarbeit ( § 12 Teilzeit- und Befristungsgesetz – TzBfG ) zur Verfügung. In dem nachfolgenden Beitrag werden Möglichkeiten und Grenzen der Abrufarbeit skizziert und konkrete arbeitsvertragliche Gestaltungsmöglichkeiten aufgezeigt.
Eigenkapitalkosten sind eine wesentliche Determinante bei der Wertbestimmung von Unternehmen und Unternehmensteilen. Die Eigenkapitalkosten werden regelmäßig mittels des CAPM bestimmt. Für sog. konzerninterne Routinefunktionen mit geringem Risiko stellt diese Bestimmung mittels CAPM ein Problem dar, da börsennotierte Peergroups für eine zuverlässige Bestimmung des Beta-Faktors meist nicht identifizierbar sind. Damit ergeben sich bei Bewertungen von Routineunternehmen Unsicherheiten und Konfliktpotenzial in steuerlichen Betriebsprüfungen. Dieser Beitrag gibt einen Überblick der in der Praxis genutzten Ansätze und stellt eine theoretische Fundierung zur Bestimmung der Eigenkapitalkosten von konzerninternen Routinefunktionen vor. Dabei wird verdeutlicht, dass Eigenkapitalkosten von konzerninternen Routinefunktionen nicht denen des Gesamtkonzerns entsprechen und Praktikeransätze eine grundsätzliche Berechtigung besitzen.