Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1543)
- Fachbereich Wirtschaftswissenschaften (700)
- Fachbereich Elektrotechnik und Informationstechnik (629)
- Fachbereich Energietechnik (598)
- Fachbereich Chemie und Biotechnologie (588)
- INB - Institut für Nano- und Biotechnologien (524)
- Fachbereich Maschinenbau und Mechatronik (463)
- IfB - Institut für Bioengineering (427)
- Fachbereich Luft- und Raumfahrttechnik (367)
- Fachbereich Bauingenieurwesen (327)
Has Fulltext
- no (5514) (remove)
Language
Document Type
- Article (5514) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- impedance spectroscopy (3)
Dual frequency magnetic excitation of magnetic nanoparticles (MNP) enables enhanced biosensing applications. This was studied from an experimental and theoretical perspective: nonlinear sum-frequency components of MNP exposed to dual-frequency magnetic excitation were measured as a function of static magnetic offset field. The Langevin model in thermodynamic equilibrium was fitted to the experimental data to derive parameters of the lognormal core size distribution. These parameters were subsequently used as inputs for micromagnetic Monte-Carlo (MC)-simulations. From the hysteresis loops obtained from MC-simulations, sum-frequency components were numerically demodulated and compared with both experiment and Langevin model predictions. From the latter, we derived that approximately 90% of the frequency mixing magnetic response signal is generated by the largest 10% of MNP. We therefore suggest that small particles do not contribute to the frequency mixing signal, which is supported by MC-simulation results. Both theoretical approaches describe the experimental signal shapes well, but with notable differences between experiment and micromagnetic simulations. These deviations could result from Brownian relaxations which are, albeit experimentally inhibited, included in MC-simulation, or (yet unconsidered) cluster-effects of MNP, or inaccurately derived input for MC-simulations, because the largest particles dominate the experimental signal but concurrently do not fulfill the precondition of thermodynamic equilibrium required by Langevin theory.
This paper introduces a new maritime search and rescue system based on S-band illumination harmonic radar (HR). Passive and active tags have been developed and tested while attached to life jackets and a small boat. In this demonstration test carried out on the Baltic Sea, the system was able to detect and range the active tags up to a distance of 5800 m using an illumination signal transmit-power of 100 W. Special attention is given to the development, performance, and conceptual differences between passive and active tags used in the system. Guidelines for achieving a high HR dynamic range, including a system components description, are given and a comparison with other HR systems is performed. System integration with a commercial maritime X-band navigation radar is shown to demonstrate a solution for rapid search and rescue response and quick localization.