Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (1152) (remove)
Has Fulltext
- no (1152) (remove)
Document Type
- Article (621)
- Conference Proceeding (294)
- Book (112)
- Part of a Book (66)
- Patent (17)
- Report (9)
- Other (8)
- Conference: Meeting Abstract (6)
- Contribution to a Periodical (6)
- Doctoral Thesis (6)
Keywords
- Enterprise Architecture (5)
- MINLP (5)
- Engineering optimization (4)
- Digitale Transformation (3)
- Digitalisierung (3)
- Gamification (3)
- Literaturanalyse (3)
- Optimization (3)
- Powertrain (3)
- Referenzmodellierung (3)
The aim of the current study was to investigate the performance of integrated RF
transmit arrays with high channel count consisting of meander microstrip antennas
for body imaging at 7 T and to optimize the position and number of transmit ele-
ments. RF simulations using multiring antenna arrays placed behind the bore liner
were performed for realistic exposure conditions for body imaging. Simulations were
performed for arrays with as few as eight elements and for arrays with high channel
counts of up to 48 elements. The B1+ field was evaluated regarding the degrees of
freedom for RF shimming in the abdomen. Worst-case specific absorption rate
(SARwc ), SAR overestimation in the matrix compression, the number of virtual obser-
vation points (VOPs) and SAR efficiency were evaluated. Constrained RF shimming
was performed in differently oriented regions of interest in the body, and the devia-
tion from a target B1+ field was evaluated. Results show that integrated multiring
arrays are able to generate homogeneous B1+ field distributions for large FOVs, espe-
cially for coronal/sagittal slices, and thus enable body imaging at 7 T with a clinical
workflow; however, a low duty cycle or a high SAR is required to achieve homoge-
neous B1+ distributions and to exploit the full potential. In conclusion, integrated
arrays allow for high element counts that have high degrees of freedom for the pulse
optimization but also produce high SARwc , which reduces the SAR accuracy in the
VOP compression for low-SAR protocols, leading to a potential reduction in array
performance. Smaller SAR overestimations can increase SAR accuracy, but lead to a
high number of VOPs, which increases the computational cost for VOP evaluation
and makes online SAR monitoring or pulse optimization challenging. Arrays with
interleaved rings showed the best results in the study.
Wie kann man das Thema Forschungsdatenmanagement (FDM) konkret und anwendbar für Forschende gestalten, die bisher noch wenig Kontakt damit hatten? Auf diese Frage gibt das Konzept „30 Minuten FDM für HAW. Ein Informationsformat für Forschende an HAW in NRW“ eine Antwort. Es entstand als Projektarbeit im Zertifikatskurs Forschungsdatenmanagement 2023/24
Um die Forschungsdatenmanagement-Plattform Coscine optimal für Forschungsprojekte nutzen zu können, ist es sinnvoll, einige Fragen im Vorhinein zu klären. So können aufwendige Änderungen der Datenverwaltung im Nachhinein vermieden werden. Hierzu bietet die Handreichung hilfreiche Leitfragen und Erläuterungen für Forschende und FDM-Service-Personal an HAW in NRW (DH.NRW-Hochschulen).
FDM-Service-Mitarbeitende können die Handreichung in ihrer Beratung zu Coscine einsetzen und mit der Eingabemaske in der Kopfzeile des Dokuments auf ihre Hochschule anpassen.
Welche Vorteile bietet die Forschungsdatenmanagement-Plattform Coscine für die Verwaltung von Daten in Forschungsprojekten? Hierzu gibt die Handreichung einen schnellen Überblick über den landesgeförderten Dienst Coscine für Forschende und FDM-Service-Personal an HAW in NRW (DH.NRW-Hochschulen).
FDM-Service-Mitarbeitende können die Handreichung in ihrer Beratung zu Coscine einsetzen und mit der Eingabemaske in der Kopfzeile des Dokuments auf ihre Hochschule anpassen.
After a brief introduction of conventional laboratory structures, this work focuses on an innovative and universal approach for a setup of a training laboratory for electric machines and drive systems. The novel approach employs a central 48 V DC bus, which forms the backbone of the structure. Several sets of DC machine, asynchronous machine and synchronous machine are connected to this bus. The advantages of the novel system structure are manifold, both from a didactic and a technical point of view: Student groups can work on their own performance level in a highly parallelized and at the same time individualized way. Additional training setups (similar or different) can easily be added. Only the total power dissipation has to be provided, i.e. the DC bus balances the power flow between the student groups. Comparative results of course evaluations of several cohorts of students are shown.
The Inverted Rotary Pendulum: Facilitating Practical Teaching in Advanced Control Engineering
(2024)
This paper outlines a practical approach to teach control engineering principles, with an inverted rotary pendulum, serving as an illustrative example. It shows how the pendulum is embedded in an advanced course of control engineering. This approach is incorporated into a flipped-classroom concept, as well as classical teaching concepts, offering students practical experience in control engineering. In addition, the design of the pendulum is shown, using a Raspberry Pi as the target platform for Matlab Simulink. This pendulum can be used in the classroom to evaluate the controller design mentioned above. It is analysed if the use of the pendulum generates a deeper understanding of the learning contents.
This paper serves as an introduction to the ECTS monitoring system and its potential applications in higher education. It also emphasizes the potential for ECTS monitoring to become a proactive system, supporting students by predicting academic success and identifying groups of potential dropouts for tailored support services. The use of the nearest neighbor analysis is suggested for improving data analysis and prediction accuracy.
Das Diskussionspapier beschreibt einen Prozess an der FH Aachen zur Entwicklung und Implementierung eines Self-Assessment-Tools für Studiengänge. Dieser Prozess zielte darauf ab, die Relevanz der Themen Digitalisierung, Internationalisierung und Nachhaltigkeit in Studiengängen zu stärken. Durch Workshops und kollaborative Entwicklung mit Studiendekan:innen entstand ein Fragebogen, der zur Reflexion und strategischen Weiterentwicklung der Studiengänge dient.
Magnetic Resonance Imaging (MRI) of moving organs requires synchronization with physiological motion or flow, which dictate the viable window for data acquisition. To meet this challenge, this study proposes an acoustic gating device (ACG) that employs acquisition and processing of acoustic signals for synchronization while providing MRI compatibility, immunity to interferences with electro-magnetic and acoustic fields and suitability for MRI at high magnetic field strengths. The applicability and robustness of the acoustic gating approach is examined in a pilot study, where it substitutes conventional ECG-gating for cardiovascular MR. The merits and limitations of the ACG approach are discussed. Implications for MR imaging in the presence of physiological motion are considered including synchronization with other structure- or motion borne sounds.
Cardiac MR (CMR) at ultrahigh (≥7.0 T) fields is regarded as one of the most challenging MRI applications. At 7.0 T image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Detrimental effects bear the potential to spoil the signal-to-noise (SNR) and contrast-to-noise (CNR) benefits of cardiac MR (CMR) at 7.0 T. B₁⁺-inhomogeneities and signal voids represent the main challenges. Various pioneering coil concepts have been proposed to tackle these issues, enabling cardiac MRI at 7.0 T. This includes a trend towards an ever larger number of transmit and receive channels. This approach affords multi-dimensional B₁⁺ modulations to improve B₁⁺ shimming performance and to enhance RF efficiency. Also, parallel imaging benefits from a high number of receive channels enabling two-dimensional acceleration. Realizing the limitations of existing coil designs tailored for UHF CMR and recognizing the opportunities of a many element TX/RX channel architecture this work proposes a modular, two dimensional 32-channel transmit and receive array using loop elements and examines its efficacy for enhanced B¹+ homogeneity and improved parallel imaging performance.