Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1941)
- Fachbereich Elektrotechnik und Informationstechnik (1156)
- Fachbereich Wirtschaftswissenschaften (1124)
- Fachbereich Energietechnik (1068)
- Fachbereich Chemie und Biotechnologie (900)
- Fachbereich Maschinenbau und Mechatronik (818)
- Fachbereich Luft- und Raumfahrttechnik (772)
- Fachbereich Bauingenieurwesen (665)
- IfB - Institut für Bioengineering (630)
- INB - Institut für Nano- und Biotechnologien (586)
Has Fulltext
- no (9363) (remove)
Language
Document Type
- Article (5513)
- Conference Proceeding (1454)
- Book (1064)
- Part of a Book (574)
- Patent (177)
- Bachelor Thesis (170)
- Conference: Meeting Abstract (83)
- Report (83)
- Doctoral Thesis (82)
- Other (67)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
We present an electromechanically coupled Finite Element model for cardiac tissue. It bases on the mechanical model for cardiac tissue of Hunter et al. that we couple to the McAllister-Noble-Tsien electrophysiological model of purkinje fibre cells. The corresponding system of ordinary differential equations is implemented on the level of the constitutive equations in a geometrically and physically nonlinear version of the so-called edge-based smoothed FEM for plates. Mechanical material parameters are determined from our own pressure-deflection experimental setup. The main purpose of the model is to further examine the experimental results not only on mechanical but also on electrophysiological level down to ion channel gates. Moreover, we present first drug treatment simulations and validate the model with respect to the experiments.
Large power plants can be endangered by lightning strikes with possible consequences regarding their safety and availability. A special scenario is a lightning strike to the HV overhead transmission line close to the power plant's connection to the power grid. If then additionally a so-called shielding failure of the overhead ground wire on top of the overhead transmission line is assumed, i.e. the lightning strikes directly into a phase conductor, this is an extreme electromagnetic disturbance. The paper deals with the numerical simulation of such a lightning strike and the consequences on the components of the power plant's auxiliary power network connected to different voltage levels.