Refine
Year of publication
- 2012 (313) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (70)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Chemie und Biotechnologie (39)
- Fachbereich Elektrotechnik und Informationstechnik (37)
- Fachbereich Bauingenieurwesen (30)
- INB - Institut für Nano- und Biotechnologien (30)
- IfB - Institut für Bioengineering (29)
- Fachbereich Maschinenbau und Mechatronik (27)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
Has Fulltext
- no (313) (remove)
Document Type
- Article (129)
- Conference Proceeding (81)
- Part of a Book (36)
- Book (26)
- Conference: Meeting Abstract (17)
- Patent (12)
- Doctoral Thesis (6)
- Report (3)
- Habilitation (1)
- Other (1)
Keywords
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
- Acceleration (1)
- Adsorption (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Autolysis (1)
- Avalanche (1)
With its need for high SNR and short acquisition times, Cardiac MRI (CMR) is an intriguing target application for ultrahigh field MRI. Due to the sheer size of the upper torso, however, the known RF issues of 7T MRI are also most prominent in CMR. Recent years brought substantial progress but the full potential of the ultrahigh field for CMR is yet to be exploited. Parallel transmission (pTx) is a promising approach in this context and several groups have already reported B1 shimming for 7T CMR. In such a static pTx application amplitudes and phases of all Tx channels are adjusted individually but otherwise imaging techniques established in current clinical practice 1.5 T and 3 T are applied. More advanced forms of pTx as spatially selective excitation (SSE) using Transmit SENSE promise additional benefits like faster imaging with reduced fields of view or improved SAR control. SSE requires the full dynamic capabilities of pTx, however, and for the majority of today's implemented pTx hardware the internal synchronization of the Tx array does not easily permit external triggering as needed for CMR. Here we report a software solution to this problem and demonstrate the feasibility of CINE CMR at 7 T using a Tx array.
Spontaneous language has rarely been subjected to neuroimaging studies. This study therefore introduces a newly developed method for the analysis of linguistic phenomena observed in continuous language production during fMRI.
Most neuroimaging studies investigating language have so far focussed on single word or — to a smaller extent — sentence processing, mostly due to methodological considerations. Natural language production, however, is far more than the mere combination of words to larger units. Therefore, the present study aimed at relating brain activation to linguistic phenomena like word-finding difficulties or syntactic completeness in a continuous language fMRI paradigm. A picture description task with special constraints was used to provoke hesitation phenomena and speech errors. The transcribed speech sample was segmented into events of one second and each event was assigned to one category of a complex schema especially developed for this purpose. The main results were: conceptual planning engages bilateral activation of the precuneus. Successful lexical retrieval is accompanied – particularly in comparison to unsolved word-finding difficulties – by the left middle and superior temporal gyrus. Syntactic completeness is reflected in activation of the left inferior frontal gyrus (IFG) (area 44). In sum, the method has proven to be useful for investigating the neural correlates of lexical and syntactic phenomena in an overt picture description task. This opens up new prospects for the analysis of spontaneous language production during fMRI.
Purpose:
To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle.
Materials and Methods:
The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization.
Results:
The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs.
Conclusion:
This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc.
A magnetic resonance tomography (MRT) apparatus (1) for the examination of a body (14) comprises parameter acquisition devices (13) for the acquisition of cardiovascular parameters of the body (14) and a control device (15) in communication with the parameter acquisition devices (13) for synchronizing the imaging, wherein the control device (15) is adapted to analyse the data of at least two parameter acquisition devices (13) and to output a control signal based on the analysis.
Prioritization is an essential task within requirements engineering to cope with complexity and to establish focus properly. The 3rd Workshop on Requirements Prioritization for customer oriented Software Development (RePriCo’12) focused on requirements prioritization and adjacent themes in the context of customer oriented development of bespoke and standard software. Five submissions have been accepted for the proceedings and for presentation. The report summarizes and points out key findings.
Die Veränderungen des Telekommunikationsmarktes haben in der Praxis zu einer Vielzahl von Transformationsprojekten geführt. Was gehört aber zu einem “Transformationsprojekt”, welche Prozesse und Systeme werden verändert? Zur Beantwortung dieser Frage haben wir 184 Berichte zu Projekten analysiert, die als "Transformationsprojekte" bezeichnet waren. Für die Analyse haben wir einen Kodierungsrahmen konzipiert und anhand dessen die Berichte mit einem hierarchischen Clustering-Verfahren in Themen gruppiert. Die Ergebnisse liefern Hinweise über die in der Praxis gesetzten Schwerpunkte und Prioritäten. Sie können
somit als Unterstützung für Unternehmen dienen, die ein Transformationsprojekt planen. Sie weisen zudem darauf hin, in welchen Bereichen eines Unternehmens Unterstützung durch wissenschaftlich erprobte Werkzeuge und Modelle nötig ist.
As the potential of a next generation network (NGN) is recognised, telecommunication companies consider switching to it. Although the implementation of an NGN seems to be merely a modification of the network infrastructure, it may trigger or require changes in the whole company, because it builds upon the separation between service and transport, a flexible bundling of services to products and the streamlining of the IT infrastructure. We propose a holistic framework, structured into the layers ‘strategy’, ‘processes’ and ‘information systems’ and incorporate into each layer all concepts necessary for the implementation of an NGN, as well as the alignment of these concepts. As a first proof-of-concept for our framework we have performed a case study on the introduction of NGN in a large telecommunication company; we show that our framework captures all topics that are affected by an NGN implementation.
Netzsektoren und deren adäquate Regulierung sind ein sehr relevantes und aktuelles Thema. Dies gilt sowohl für die ökonomische Theorie, die sich sehr intensiv damit auseinandersetzt und in den letzten Jahrzehnten zahlreiche neue Erkenntnisse gewonnen hat. Es gilt ebenso für die Politik, in der Regulierungsfragen kontrovers diskutiert werden und dies nicht nur unter ökonomischen Gesichtspunkten. Es gilt selbstverständlich für die regulierten Unternehmen selbst, deren Tätigkeit durch die staatlichen Regulierungsvorgaben markant beeinflusst wird. Nicht nur die konkreten Inhalte der Regulierungsregime sowie die verbleibenden Freiheitsgrade in der Ausgestaltung sind von Bedeutung, sondern ebenso die Umsetzung durch die Regulierungsbehörden. All dies gilt für den Strommarkt und seinen regulatorischen Hintergrund in besonderer Weise. Die Entflechtung der Stromübertragungsnetze von der Stromproduktion und damit die Vorgaben für die Organisation der Wertschöpfungsketten in den Elektrizitätsunternehmen sind seit dem Beginn des europäischen Liberalisierungsprozesses der Strommärkte ein wichtiges und kontrovers diskutiertes Regulierungselement. Den Fokus bildet das vertikale Unbundling, das letztlich die Diskriminierung von Wettbewerbern durch Anbieter mit aggregierten Wertschöpfungsketten verhindern soll, indem diese gezwungen werden, ihren "Netzteil" anders zu organisieren oder zu verkaufen. Den Mitgliedsstaaten blieben Freiräume in der Ausgestaltung, die in Deutschland erst vor kurzem konkretisiert wurden, und die für die regulierten Unternehmen die Nutzung eines Wahlrechts beinhalten. Der wirtschaftspolitischen folgt nun eine unternehmerische Abwägungsentscheidung.