Refine
Year of publication
- 2009 (188) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (73)
- IfB - Institut für Bioengineering (33)
- Fachbereich Elektrotechnik und Informationstechnik (27)
- INB - Institut für Nano- und Biotechnologien (26)
- Fachbereich Luft- und Raumfahrttechnik (18)
- Fachbereich Chemie und Biotechnologie (16)
- Fachbereich Energietechnik (13)
- Solar-Institut Jülich (12)
- Fachbereich Maschinenbau und Mechatronik (9)
- Fachbereich Bauingenieurwesen (6)
Language
- English (188) (remove)
Document Type
- Article (121)
- Conference Proceeding (52)
- Part of a Book (7)
- Book (3)
- Conference: Meeting Abstract (1)
- Doctoral Thesis (1)
- Patent (1)
- Talk (1)
- Working Paper (1)
Keywords
- Papierkunst (3)
- Spacecraft (2)
- Stickstoffmonoxid (2)
- nitric oxide gas (2)
- Adsorption (1)
- Aktionskunst (1)
- Autofluoreszenzverfahren (1)
- Biophoton (1)
- Biosensor (1)
- Blitzschutz (1)
Solar-electric propulsion (SEP) is superior with
respect to payload capacity, flight time and
flexible launch window to the conventional
interplanetary transfer method using chemical
propulsion combined with gravity assists. This fact
results from the large exhaust velocities of electric
low–thrust propulsion and is favourable also for
missions to the giant planets, Kuiper-belt objects
and even for a heliopause probe (IHP) as shown in
three studies by the authors funded by DLR. They
dealt with a lander for Europa and a sample return
mission from a mainbelt asteroid [1], with the
TANDEM mission [2]; the third recent one
investigates electric propulsion for the transfer to
the edge of the solar system.
All studies are based on triple-junction solar arrays,
on rf-ion thrusters of the qualified RIT-22 type and
they use the intelligent trajectory optimization
program InTrance [3].
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.