Refine
Year of publication
- 2012 (314) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (70)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Chemie und Biotechnologie (39)
- Fachbereich Elektrotechnik und Informationstechnik (38)
- Fachbereich Bauingenieurwesen (30)
- INB - Institut für Nano- und Biotechnologien (30)
- IfB - Institut für Bioengineering (29)
- Fachbereich Maschinenbau und Mechatronik (27)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
Has Fulltext
- no (314) (remove)
Document Type
- Article (129)
- Conference Proceeding (81)
- Part of a Book (36)
- Book (26)
- Conference: Meeting Abstract (17)
- Patent (12)
- Doctoral Thesis (7)
- Report (3)
- Habilitation (1)
- Other (1)
Keywords
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
- Acceleration (1)
- Adsorption (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Autolysis (1)
- Avalanche (1)
Entwicklung eines Prototypen zur Prognose von Frühgeburten : ein biomedizintechnischer Ansatz
(2012)
In this paper we consider low Péclet number flow in bead packs. A series of relaxation exchange experiments has been conducted and evaluated by ILT analysis. In the resulting correlation maps, we observed a collapse of the signal and a translation towards smaller relaxation times with increasing flow rates, as well as a signal tilt with respect to the diagonal. In the discussion of the phenomena we present a mathematical theory for relaxation exchange experiments that considers both diffusive and advective transport. We perform simulations based on this theory and discuss them with respect to the conducted experiments.
Wieder einmal hat eine Entscheidung des Europäischen Gerichtshofs (EuGH) das bisherige nationale Verständnis zu einer Frage des Rechts des Betriebsübergangs erheblich ins Wanken gebracht. Bisher entsprach es allgemeiner Auffassung, dass die Arbeitsverhältnisse von Zeit- bzw. Leiharbeitnehmern bei einem Betriebs(teil)übergang des die Leiharbeitnehmer entleihenden Betriebs nicht auf den Betriebserwerber übergehen. Der EuGH hat in der Rechtssache Albron Catering mit Urteil vom 21.10.2010 jedoch entschieden, dass auch Leiharbeitnehmer von einem Betriebs(teil)übergang erfasst sein können. Folglich kann der Erwerber eines Betriebs oder Betriebsteils gem. § 613a BGB zukünftig verpflichtet sein, auch die an den Betriebsveräußerer verliehenen Leiharbeitnehmer zu übernehmen. Die Entscheidung des EuGH hat somit zur Konsequenz, dass der Übergang von Leiharbeitsverhältnissen auf den Erwerber eines Betriebs jedenfalls nicht mehr pauschal ausgeschlossen werden kann. Dies gilt es bei künftigen Betriebs(teil)übertragungen zu berücksichtigen, um unliebsame Überraschungen zu vermeiden.
s the magnetic field strength and therefore the operational frequency in MRI are increased, the radiofrequency wavelength approaches the size of the human head/body, resulting in wave effects which cause signal decreases and dropouts. Especially, whole-body imaging at 7 T and higher is therefore challenging. Recently, an acquisition scheme called time-interleaved acquisition of modes has been proposed to tackle the inhomogeneity problems in high-field MRI. The basic premise is to excite two (or more) different Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-1 modes using static radiofrequency shimming in an interleaved acquisition, where the complementary radiofrequency patterns of the two modes can be exploited to improve overall signal homogeneity. In this work, the impact of time-interleaved acquisition of mode on image contrast as well as on time-averaged specific absorption rate is addressed in detail. Time-interleaved acquisition of mode is superior in Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-2 homogeneity compared with conventional radiofrequency shimming while being highly specific absorption rate efficient. Time-interleaved acquisition of modes can enable almost homogeneous high-field imaging throughout the entire field of view in PD, T2, and T2*-weighted imaging and, if a specified homogeneity criterion is met, in T1-weighted imaging as well.
Air- and water-stable phenyl complexes with nitridotechnetium(V) cores can be prepared by straightforward procedures. [TcNPh2(PPh3)2] is formed by the reaction of [TcNCl2(PPh3)2] with PhLi. The analogous N-heterocyclic carbene (NHC) compound [TcNPh2(HLPh)2], where HLPh is 1,3,4-triphenyl-1,2,4-triazol-5-ylidene, is available from (NBu4)[TcNCl4] and HLPh or its methoxo-protected form. The latter compound allows the comparison of different Tc–C bonds within one compound. Surprisingly, the Tc chemistry with such NHCs does not resemble that of corresponding Re complexes, where CH activation and orthometalation dominate.
N,N-Dialkylamino(thiocarbonyl)-N′-picolylbenzamidines react with (NEt4)2[M(CO)3X3] (M = Re, X = Br; M = Tc, X = Cl) under formation of neutral [M(CO)3L] complexes in high yields. The monoanionic NNS ligands bind in a facial coordination mode and can readily be modified at the (CS)NR1R2 moiety. The complexes [99Tc(CO)3(LPyMor)] and [Re(CO)3(L)] (L = LPyMor, LPyEt) were characterized by X-ray diffraction. Reactions of [99mTc(CO)3(H2O)3]+ with the N′-thiocarbamoylpicolylbenzamidines give the corresponding 99mTc complexes. The ester group in HLPyCOOEt allows linkage between biomolecules and the metal core.
Often, detailed simulations of heat conduction in complicated, porous media have large runtimes. Then homogenization is a powerful tool to speed up the calculations by preserving accurate solutions at the same time. Unfortunately real structures are generally non-periodic, which requires unpractical, complicated homogenization techniques. We demonstrate in this paper, that the application of simple, periodic techniques to realistic media, that are just close to periodic, gives accurate, approximative solutions. In order to obtain effective parameters for the homogenized heat equation, we have to solve a so called “cell problem”. In contrast to periodic structures it is not trivial to determine a suitable unit cell, which represents a non-periodic media. To overcome this problem, we give a rule of thumb on how to choose a good cell. Finally we demonstrate the efficiency of our method for virtually generated foams as well as real foams and compare these results to periodic structures.