Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1687)
- Fachbereich Elektrotechnik und Informationstechnik (717)
- IfB - Institut für Bioengineering (622)
- Fachbereich Energietechnik (588)
- INB - Institut für Nano- und Biotechnologien (557)
- Fachbereich Chemie und Biotechnologie (551)
- Fachbereich Luft- und Raumfahrttechnik (496)
- Fachbereich Maschinenbau und Mechatronik (278)
- Fachbereich Wirtschaftswissenschaften (217)
- Solar-Institut Jülich (165)
Language
- English (4905) (remove)
Document Type
- Article (3273)
- Conference Proceeding (1162)
- Part of a Book (191)
- Book (144)
- Doctoral Thesis (30)
- Conference: Meeting Abstract (28)
- Patent (25)
- Other (10)
- Report (9)
- Conference Poster (6)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- Blitzschutz (6)
- FEM (6)
- Gamification (6)
- Limit analysis (6)
A concept for a sensitive micro total analysis system for high throughput fluorescence imaging
(2006)
This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background.
A melting probe equipped with autofluorescence-based detection system combined with a light scattering unit, and, optionally, with a microarray chip would be ideally suited to probe icy environments like Europa’s ice layer as well as the polar ice layers of Earth and Mars for recent and extinct live.
Cyberspace is "the environment formed by physical and non-physical components to store, modify, and exchange data using computer networks" (NATO CCDCOE). Beyond that, it is an environment where people interact. IT attacks are hostile, non-cooperative interactions that can be described with conflict theory. Applying conflict theory to IT security leads to different objectives for end-user education, requiring different formats like agency-based competence developing games.
A nonparametric goodness-of-fit test for random variables with values in a separable Hilbert space is investigated. To verify the null hypothesis that the data come from a specific distribution, an integral type test based on a Cramér-von-Mises statistic is suggested. The convergence in distribution of the test statistic under the null hypothesis is proved and the test's consistency is concluded. Moreover, properties under local alternatives are discussed. Applications are given for data of huge but finite dimension and for functional data in infinite dimensional spaces. A general approach enables the treatment of incomplete data. In simulation studies the test competes with alternative proposals.
An improved and convenient ninhydrin assay for aminoacylase activity measurements was developed using the commercial EZ Nin™ reagent. Alternative reagents from literature were also evaluated and compared. The addition of DMSO to the reagent enhanced the solubility of Ruhemann's purple (RP). Furthermore, we found that the use of a basic, aqueous buffer enhances stability of RP. An acidic protocol for the quantification of lysine was developed by addition of glacial acetic acid. The assay allows for parallel processing in a 96-well format with measurements microtiter plates.