Refine
Year of publication
Document Type
- Article (5464) (remove)
Language
Has Fulltext
- no (5464) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
- snow (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Chemometrics (2)
- Datenschutz (2)
- Datenschutzgrundverordnung (2)
- Drinfeld modules (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (1531)
- Fachbereich Wirtschaftswissenschaften (683)
- Fachbereich Elektrotechnik und Informationstechnik (617)
- Fachbereich Energietechnik (597)
- Fachbereich Chemie und Biotechnologie (585)
- INB - Institut für Nano- und Biotechnologien (523)
- Fachbereich Maschinenbau und Mechatronik (463)
- IfB - Institut für Bioengineering (426)
- Fachbereich Luft- und Raumfahrttechnik (364)
- Fachbereich Bauingenieurwesen (324)
- Solar-Institut Jülich (105)
- Fachbereich Architektur (76)
- Fachbereich Gestaltung (55)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (39)
- ECSM European Center for Sustainable Mobility (33)
- Nowum-Energy (28)
- Sonstiges (23)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (18)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (15)
Biomedical applications of magnetic nanoparticles (MNP) fundamentally rely on the particles’ magnetic relaxation as a response to an alternating magnetic field. The magnetic relaxation complexly depends on the interplay of MNP magnetic and physical properties with the applied field parameters. It is commonly accepted that particle core size is a major contributor to signal generation in all the above applications, however, most MNP samples comprise broad distribution spanning nm and more. Therefore, precise knowledge of the exact contribution of individual core sizes to signal generation is desired for optimal MNP design generally for each application. Specifically, we present a magnetic relaxation simulation-driven analysis of experimental frequency mixing magnetic detection (FMMD) for biosensing to quantify the contributions of individual core size fractions towards signal generation. Applying our method to two different experimental MNP systems, we found the most dominant contributions from approx. 20 nm sized particles in the two independent MNP systems. Additional comparison between freely suspended and immobilized MNP also reveals insight in the MNP microstructure, allowing to use FMMD for MNP characterization, as well as to further fine-tune its applicability in biosensing.