Refine
Year of publication
- 2014 (166) (remove)
Document Type
- Article (93)
- Conference Proceeding (51)
- Part of a Book (14)
- Book (3)
- Doctoral Thesis (1)
- Master's Thesis (1)
- Patent (1)
- Poster (1)
- Report (1)
Language
- English (166) (remove)
Keywords
- Antarctic Glaciology (1)
- Bloom Taxonomy (1)
- Bone sawing (1)
- COMSOL Multiphysics (1)
- Calorimetric gas sensor (1)
- Cryptographic protocols (1)
- DNA hybridization (1)
- Extraterrestrial Glaciology (1)
- Field-effect sensor (1)
- Glaciological instruments and methods (1)
- Hydrogen peroxide (1)
- LAPS (1)
- Light-addressable Potentiometric Sensor (1)
- LiveLink for MATLAB (1)
- Malicious model (1)
- Multi-sensor system (1)
- Optimization module (1)
- Privacy-enhancing technologies (1)
- Secure multi-party computation (1)
- Subclacial exploration (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (58)
- INB - Institut für Nano- und Biotechnologien (34)
- Fachbereich Chemie und Biotechnologie (24)
- Fachbereich Elektrotechnik und Informationstechnik (24)
- IfB - Institut für Bioengineering (24)
- Fachbereich Energietechnik (22)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Wirtschaftswissenschaften (6)
- Fachbereich Bauingenieurwesen (4)
- Solar-Institut Jülich (4)
- Fachbereich Maschinenbau und Mechatronik (3)
- Sonstiges (3)
- ECSM European Center for Sustainable Mobility (1)
- Institut fuer Angewandte Polymerchemie (1)
For the sterilisation of aseptic food packages it is taken advantage of the microbicidal properties of hydrogen peroxide (H2O2). Especially, when applied in vapour phase, it has shown high potential of microbial inactivation. In addition, it offers a high environmental compatibility compared to other chemical sterilisation agents, as it decomposes into oxygen and water, respectively. Due to a lack in sensory detection possibilities, a continuous monitoring of the H2O2 concentration was recently not available. Instead, the sterilisation efficacy is validated using microbiological tests. However, progresses in the development of calorimetric gas sensors during the last 7 years have made it possible to monitor the H2O2 concentration during operation. This chapter deals with the fundamentals of calorimetric gas sensing with special focus on the detection of gaseous hydrogen peroxide. A sensor principle based on a calorimetric differential set-up is described. Special emphasis is given to the sensor design with respect to the operational requirements under field conditions. The state-of-the-art regarding a sensor set-up for the on-line monitoring and secondly, a miniaturised sensor for in-line monitoring are summarised. Furthermore, alternative detection methods and a novel multi-sensor system for the characterisation of aseptic sterilisation processes are described.
Multi-parameter detection for supporting monitoring and control of biogas processes in agriculture
(2014)