Refine
Year of publication
- 2024 (107) (remove)
Institute
- Fachbereich Gestaltung (31)
- Fachbereich Medizintechnik und Technomathematik (21)
- Fachbereich Bauingenieurwesen (14)
- Fachbereich Elektrotechnik und Informationstechnik (13)
- Fachbereich Wirtschaftswissenschaften (11)
- Fachbereich Luft- und Raumfahrttechnik (8)
- INB - Institut für Nano- und Biotechnologien (7)
- IfB - Institut für Bioengineering (7)
- Fachbereich Chemie und Biotechnologie (6)
- ECSM European Center for Sustainable Mobility (5)
Document Type
- Article (35)
- Bachelor Thesis (31)
- Part of a Book (16)
- Conference Proceeding (11)
- Working Paper (6)
- Book (5)
- Preprint (2)
- Patent (1)
Keywords
- Nachhaltigkeit (4)
- Deutschland (2)
- Digitalisierung (2)
- Dokumentarfilm (2)
- Engineering education (2)
- Fashion (2)
- Hot S-parameter (2)
- Kultur (2)
- Magazin (2)
- 1P hub loads (1)
Zugriffsart
- weltweit (44)
- campus (26)
- bezahl (12)
- fachbereichsweit (FB4) (5)
The “1. Stokes’ problem”, the “suddenly accelerated flat wall”, is the oldest application of the Navier-Stokes equations. Stokes’ solution of the “problem” does not comply with the mathematical theorem of Cauchy and Kowalewskaya on the “Uniqueness and Existence” of solutions of partial differential equations and violates the physical theorem of minimum entropy production/dissipation of the Thermodynamics of Irreversible Processes. The result includes very high local shear stresses and dissipation rates. That is of special interest for the theory of turbulent and mixed turbulent/laminar flow. A textbook solution of the “1. Stokes Problem” is the Couette flow, which has a constant sheer stress along a linear profile. A consequence is that the Navier-Stokes equations do not describe any S-shaped part of a turbulent profile found in any turbulent Couette experiment. The paper surveys arguments referring to that statement, concerning the history of >150 years. Contrary to this there is always a Navier-Stokes solution near the wall, observed by a linear part of the Couette profile. There a turbulent description (e.g. by the logarithmic law-of-the-wall) fails completely. That is explained by the minimum dissipation requirement together with the Couette feature τ = const. The local co-existence of a turbulent zone and a laminar zone near the wall is stable and observed also at high Reynolds-Numbers.
The artificial olfactory image was proposed by Lundström et al. in 1991 as a new strategy for an electronic nose system which generated a two-dimensional mapping to be interpreted as a fingerprint of the detected gas species. The potential distribution generated by the catalytic metals integrated into a semiconductor field-effect structure was read as a photocurrent signal generated by scanning light pulses. The impact of the proposed technology spread beyond gas sensing, inspiring the development of various imaging modalities based on the light addressing of field-effect structures to obtain spatial maps of pH distribution, ions, molecules, and impedance, and these modalities have been applied in both biological and non-biological systems. These light-addressing technologies have been further developed to realize the position control of a faradaic current on the electrode surface for localized electrochemical reactions and amperometric measurements, as well as the actuation of liquids in microfluidic devices.
To gain insight on chemical sterilization processes, the influence of temperature (up to 70 °C), intense green light, and hydrogen peroxide (H₂O₂) concentration (up to 30% in aqueous solution) on microbial spore inactivation is evaluated by in-situ Raman spectroscopy with an optical trap. Bacillus atrophaeus is utilized as a model organism. Individual spores are isolated and their chemical makeup is monitored under dynamically changing conditions (temperature, light, and H₂O₂ concentration) to mimic industrially relevant process parameters for sterilization in the field of aseptic food processing. While isolated spores in water are highly stable, even at elevated temperatures of 70 °C, exposure to H₂O₂ leads to a loss of spore integrity characterized by the release of the key spore biomarker dipicolinic acid (DPA) in a concentration-dependent manner, which indicates damage to the inner membrane of the spore. Intensive light or heat, both of which accelerate the decomposition of H₂O₂ into reactive oxygen species (ROS), drastically shorten the spore lifetime, suggesting the formation of ROS as a rate-limiting step during sterilization. It is concluded that Raman spectroscopy can deliver mechanistic insight into the mode of action of H₂O₂-based sterilization and reveal the individual contributions of different sterilization methods acting in tandem.
Muscle function is compromised by gravitational unloading in space affecting overall musculoskeletal health. Astronauts perform daily exercise programmes to mitigate these effects but knowing which muscles to target would optimise effectiveness. Accurate inflight assessment to inform exercise programmes is critical due to lack of technologies suitable for spaceflight. Changes in mechanical properties indicate muscle health status and can be measured rapidly and non-invasively using novel technology. A hand-held MyotonPRO device enabled monitoring of muscle health for the first time in spaceflight (> 180 days). Greater/maintained stiffness indicated countermeasures were effective. Tissue stiffness was preserved in the majority of muscles (neck, shoulder, back, thigh) but Tibialis Anterior (foot lever muscle) stiffness decreased inflight vs. preflight (p < 0.0001; mean difference 149 N/m) in all 12 crewmembers. The calf muscles showed opposing effects, Gastrocnemius increasing in stiffness Soleus decreasing. Selective stiffness decrements indicate lack of preservation despite daily inflight countermeasures. This calls for more targeted exercises for lower leg muscles with vital roles as ankle joint stabilizers and in gait. Muscle stiffness is a digital biomarker for risk monitoring during future planetary explorations (Moon, Mars), for healthcare management in challenging environments or clinical disorders in people on Earth, to enable effective tailored exercise programmes.
In this paper, the use of reinforcement learning (RL) in control systems is investigated using a rotatory inverted pendulum as an example. The control behavior of an RL controller is compared to that of traditional LQR and MPC controllers. This is done by evaluating their behavior under optimal conditions, their disturbance behavior, their robustness and their development process. All the investigated controllers are developed using MATLAB and the Simulink simulation environment and later deployed to a real pendulum model powered by a Raspberry Pi. The RL algorithm used is Proximal Policy Optimization (PPO). The LQR controller exhibits an easy development process, an average to good control behavior and average to good robustness. A linear MPC controller could show excellent results under optimal operating conditions. However, when subjected to disturbances or deviations from the equilibrium point, it showed poor performance and sometimes instable behavior. Employing a nonlinear MPC Controller in real time was not possible due to the high computational effort involved. The RL controller exhibits by far the most versatile and robust control behavior. When operated in the simulation environment, it achieved a high control accuracy. When employed in the real system, however, it only shows average accuracy and a significantly greater performance loss compared to the simulation than the traditional controllers. With MATLAB, it is not yet possible to directly post-train the RL controller on the Raspberry Pi, which is an obstacle to the practical application of RL in a prototyping or teaching setting. Nevertheless, RL in general proves to be a flexible and powerful control method, which is well suited for complex or nonlinear systems where traditional controllers struggle.
Positionssensorvorrichtung
(2024)
Die Erfindung betrifft eine Positionssensorvorrichtung zur Bestimmung einer Absolutposition eines beweglichen ersten Teils relativ zu einem ortsfesten zweiten Teil mit einem mit dem beweglichen ersten Teil gekoppelter Codekörper, der dazu eingerichtet ist, eine Codespur mit einer Mehrzahl von in Spurrichtung aufeinanderfolgenden Codeelementen zu enthalten zur Bildung eines Codewortes, mit einer magnetischen Detektionseinrichtung zur Detektion der Codespur, wobei die Detektionseinrichtung zum einen an dem Codekörper befestigte und entlang der Spurrichtung in einem solchen Abstand gegenpolig zueinander angeordnete Permanentmagneten aufweist, dass der Abstand mit einer vorgegebenen Länge der jeweiligen Codeelemente übereinstimmt, und zum anderen eine Anzahl von ortsfest und quer zu dem Codekörper versetzt
angeordnete Wiegandsensoren aufweist, wobei der Abstand des Wiegandsensors zu einer Erstreckungsebene der Permanentmagneten derart gewählt ist, dass bei Überdeckung des Wiegandsensors durch den Permanentmagneten ein Wiegandpuls in dem Wiegandsensor induziert wird.
Electronic cigarettes (e-cigarettes) have become popular worldwide with the market growing exponentially in some countries. The absence of product standards and safety regulations requires urgent development of analytical methodologies for the holistic control of the growing diversity of such products. An approach based on low-field nuclear magnetic resonance (LF-NMR) at 80 MHz is presented for the simultaneous determination of key parameters: carrier solvents (vegetable glycerine (VG), propylene glycol (PG) and water), total nicotine as well as free-base nicotine fraction. Moreover, qualitative and quantitative determination of fourteen weak organic acids deliberately added to enhance sensory characteristics of e-cigarettes was possible. In most cases these parameters can be rapidly and conveniently determined without using any sample manipulation such as dilution, extraction or derivatization steps. The method was applied for 37 authentic e-cigarettes samples. In particular, eight different organic acids with the content up to 56 mg/mL were detected. Due to its simplicity, the method can be used in routine regulatory control as well as to study release behaviour of nicotine and other e-cigarettes constituents in different products.