Refine
Year of publication
- 2006 (41) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (26)
- Fachbereich Bauingenieurwesen (10)
- INB - Institut für Nano- und Biotechnologien (5)
- Fachbereich Maschinenbau und Mechatronik (2)
- Fachbereich Wirtschaftswissenschaften (2)
- Fachbereich Luft- und Raumfahrttechnik (1)
- IfB - Institut für Bioengineering (1)
Has Fulltext
- yes (41) (remove)
Document Type
- Conference Proceeding (41) (remove)
Keywords
- Biosensor (23)
- Bauingenieurwesen (2)
- Bauplanung (2)
- CAD (2)
- biosensor (2)
- civil engineering (2)
- 3-nitrofluoranthene (1)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (1)
- Absolvententreffen (1)
- Abwasser (1)
- Alfha.net (1)
- Alumni (1)
- Anlagenwirtschaft (1)
- BTEX compounds (1)
- Bauführung (1)
- Bauherrenvertretung (1)
- Bauleitung (1)
- Baurevision (1)
- Berufsperspektiven (1)
- Biosensorik (1)
- Bruchmechanik (1)
- CO (1)
- Conducing polymer (1)
- Deutsche Bahn Netz AG (1)
- ECT (1)
- EPN (1)
- Fluorescence (1)
- Führung (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Gewässerausbau (1)
- Gunn diode (1)
- Hand-on-training (1)
- Hauptbahnhof Aachen (1)
- Hausanschluss (1)
- Heavy metal detection (1)
- High throughput experimentation (1)
- Hochdruckleitung (1)
- Hochwasserschutz (1)
- Hotplate (1)
- Hydrogen sensor (1)
- I3S 2005 (1)
- ISFET (1)
- Ingenieurbau (1)
- International Symposium on Sensor Science (1)
- Kanalbetrieb (1)
- Kanalnetz (1)
- Karosseriebau (1)
- Konstruktiver Ingenieurbau (1)
- LED chip (1)
- Leadership (1)
- Leitungsbau (1)
- Leitungsbauunternehmen (1)
- Level sensor (1)
- Lightweight car body construction (1)
- MEMS ; education and training foundry (1)
- Main sensitivity (1)
- Microreactors (1)
- Motivation (1)
- N-A-Modelle (1)
- Nanoparticles (1)
- Nanostructuring (1)
- Niederschlag-Abfluss-Modelle (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- PFM (1)
- PIMS (1)
- Phenylalanine determination (1)
- Pipeline Integrity Management System (1)
- Potentiometry (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Reaction-diffusion (1)
- Self-Leadership (1)
- Solid amalgam electrodes (1)
- Stahlblech-Leichtmetall Verbundguss (1)
- Stahlblech-Leichtmetall-Hybride (1)
- Statiker (1)
- Technologietransfer (1)
- Telekommunikationsmarkt (1)
- Tin oxide (1)
- Tunnelbau (1)
- Umbauplanung (1)
- Verbundguss (1)
- Verkehrsbau (1)
- Virtual Technology Lab (1)
- Virtuelles Labor (1)
- Virtuelles Laboratorium (1)
- Wafer (1)
- ammonia gas sensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- capillary micro-droplet cell (1)
- carcinogens (1)
- catalytic decomposition (1)
- chemical reduction method (1)
- cross sensitivity (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- fenitrothion (1)
- fluidic (1)
- gas sensor (1)
- gas sensor array (1)
- heater metallisation (1)
- high-temperature stability (1)
- humidity (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- layer expansion (1)
- lenslet array (1)
- magnetic particles (1)
- matrix method (1)
- metal oxide (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nitrogen oxides (1)
- organic PVC membranes (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- quantum charging (1)
- screen-printing (1)
- self-aligned patterning (1)
- sensing properties (1)
- sterilisation (1)
- surface modification (1)
- swift heavy ions (1)
- technology diffusion (1)
- technology transfer (1)
- thick-film technology (1)
- thin-film microsensors (1)
- voltammetry (1)
- wafer-level testing (1)
- Öffentlich bestellter Sachverständiger (1)
Is part of the Bibliography
- no (41)
The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide.
Hands-on-training in high technology areas is usually limited due to the high cost for lab infrastructure and equipment. One specific example is the field of MEMS, where investment and upkeep of clean rooms with microtechnology equipment is either financed by production or R&D projects greatly reducing the availability for education purposes. For efficient hands-on-courses a MEMS training foundry, currently used jointly by six higher education institutions, was established at FH Kaiserslautern. In a typical one week course, students manufacture a micromachined pressure sensor including all lithography, thin film and packaging steps. This compact and yet complete program is only possible because participants learn to use the different complex machines in advance via a Virtual Training Lab (VTL). In this paper we present the concept of the MEMS training foundry and the VTL preparation together with results from a scientific evaluation of the VTL over the last three years.
Table of contents 1. Introduction 2. Multi-level Technology Transfer Infrastructure 2.1 Level 1: University Education – Encourage the Idea of becoming an Entrepreneur 2.2 Level 2: Post Graduate Education – Improve your skills and focus it on a product family. 2.3 Level 3: Birth of a Company – Focus your skills on a product and a market segment. 2.4 Level 4: Ready to stand alone – Set up your own business 2.5 Level 5: Grow to be Strong – Develop your business 2.6 Level 6: Competitive and independent – Stay innovative. 3. Samples 3.1 Sample 1: Laser Processing and Consulting Centre, LBBZ 3.2 Sample 2: Prototyping Centre, CP 4. Funding - Waste money or even lost Money? 5. Conclusion
In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff’s base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective.
Study of swift heavy ion modified conduction polymer composites for application as gas sensor
(2006)
A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.
The applicability of differential pulse voltammetry (DPV) and adsorptive stripping voltammetry (AdSV) at a non-toxic meniscus-modified silver solid amalgam electrode (m-AgSAE) for the determination of trace amounts of genotoxic substances was demonstrated on the determination of micromolar and submicromolar concentrations of 3-nitrofluoranthene using methanol - 0.01 mol L-1 NaOH (9:1) mixture as a base electrolyte and of Ostazine Orange using 0.01 mol L-1 NaOH as a base electrolyte.
In: Proc. of the 11th Intl. Conf. on Computing in Civil and Building Engineering (ICCCBE-XI) ed. Hugues Rivard, Montreal, Canada, Seite 1-12, ACSE (CD-ROM), 2006 Currently, the conceptual design phase is not adequately supported by any CAD tool. Neither the support while elaborating conceptual sketches, nor the automatic proof of correctness with respect to effective restrictions is currently provided by any commercial tool. To enable domain experts to store the common as well as their personal domain knowledge, we develop a visual language for knowledge formalization. In this paper, a major extension to the already existing concepts is introduced. The possibility to define rule dependencies extends the expressiveness of the knowledge definition language and contributes to the usability of our approach.
A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX.
Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds.