Refine
Year of publication
- 2013 (302) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- Fachbereich Elektrotechnik und Informationstechnik (43)
- INB - Institut für Nano- und Biotechnologien (40)
- Fachbereich Energietechnik (36)
- Fachbereich Wirtschaftswissenschaften (32)
- Fachbereich Chemie und Biotechnologie (29)
- IfB - Institut für Bioengineering (29)
- Fachbereich Luft- und Raumfahrttechnik (26)
- Fachbereich Bauingenieurwesen (17)
- Fachbereich Maschinenbau und Mechatronik (16)
Document Type
- Article (139)
- Conference Proceeding (77)
- Part of a Book (25)
- Book (24)
- Part of a Periodical (12)
- Report (9)
- Doctoral Thesis (6)
- Patent (4)
- Other (2)
- Conference: Meeting Abstract (1)
Keywords
We have developed a double-tuned ¹H/¹⁹F birdcage resonator dedicated for hand and wrist imaging at 7 T to locally image non-steroidal anti-inflammatory drugs (NSAID) such as 2-{[3-(Trifluoromethyl) phenyl]amino}benzoic acid. The preliminary in vivo images acquired by the double-tuned ¹H/¹⁹F birdcage resonator demonstrate the feasibility for ¹H/¹⁹F hand- and wrist-imaging at 7 T. While the diagnostic quality of the coil needs to be assessed in patients with inflammatory rheumatoid disease, first ¹⁹F images of the NSAID are encouraging, and point towards the prospect of applying ¹⁹F-MRI to visualize and quantify the concentration of therapeutically-active compound at the sites of inflammation.
Purpose
To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T.
Methods
The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study.
Results
Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly.
Conclusion
The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.
Das kompakte Nachschlagewerk für den konstruktiven Ingenieurbau wurde für den täglichen Gebrauch auf der Baustelle konzipiert und stellt alle für die rechnerische Nachweisführung und Konstruktion von Bauteilen wichtigsten Angaben in Form einer Formelsammlung mit Nachweishilfen zur Verfügung. Der Inhalt wurde auf Basis der neuen Eurocodes komplett aktualisiert und erweitert. Die 4. Auflage enthält in bewährter Manier eine umfangreiche Formelsammlung, Querschnittswerte und Bemessungshilfen zu den Bereichen Lastannahmen, Holzbau, Mauerwerksbau, Stahlbau, Stahlbetonbau, Geotechnik sowie statische Hinweise. Farbiges Papier erleichtert den zielgerichteten Zugriff auf die einzelnen Fachgebiete.
A methodology for assessment, seismic verification and strengthening of existing masonry buildings is presented in this paper. The verification is performed using a calculation model calibrated with the results from ambient vibration measurements. The calibrated model serves as an input for a deformation-based verification procedure based on the Capacity Spectrum Method (CSM). The bearing capacity of the building is calculated from experimental capacity curves of the individual walls idealized with bilinear elastic-perfectly plastic curves. The experimental capacity curves were obtained from in-plane cyclic loading tests on unreinforced and strengthened masonry walls with reinforced concrete jackets. The seismic action is compared with the load-bearing capacity of the building considering non-linear material behavior with its post-peak capacity. The application of the CSM to masonry buildings and the influence of a traditional strengthening method are demonstrated on the example of a public school building in Skopje, Macedonia.
Seismic excited liquid filled tanks are subjected to extreme loading due to hydrodynamic pressures, which can lead to nonlinear stability failure of the thinwalled cylindrical tanks, as it is known from past earthquakes. A significant reduction of the seismically induced loads can be obtained by the application of base isolation systems, which have to be designed carefully with respect to the modified hydrodynamic behaviour of the tank in interaction with the liquid. For this reason a highly sophisticated fluid-structure interaction model has to be applied for a realistic simulation of the overall dynamic system. In the following, such a model is presented and compared with the results of simplified mathematical models for rigidly supported tanks. Finally, it is examined to what extent a simple mechanical model can represent the behaviour of a base isolated tank in case of seismic excitation
Die Telekommunikationsindustrie hat in den letzten Jahrzehnten einen enormen Wandel vollzogen. Für Telekommunikationsunternehmen erfordert dies fundamentale Umstrukturierungen von Strategie, Prozessen, Anwendungssystemen und Netzwerktechnologien. Dabei spielen Unternehmensarchitekturen und Referenzmodelle eine wichtige Rolle. Zwar existieren in der Praxis anerkannte Referenzmodelle, aber wie sind diese für eine systematische Transformation zu gestalten? Wie sieht eine konkrete Lösung für die Telekommunikationsindustrie aus?
Als Antwort stellt Christian Czarnecki in seinem Buch eine referenzmodellbasierte Unternehmensarchitektur vor. Basierend auf einer umfangreichen Untersuchung von Transformationsprojekten werden Probleme und Anforderungen der Praxis identifiziert, für die mit Methoden der Unternehmenstransformation, Referenzmodellierung und Unternehmensarchitektur ein Lösungsvorschlag entwickelt und evaluiert wird. Dieser besteht u. a. aus detaillierten Anwendungsfällen, Referenzprozessabläufen, einer Zuordnung von Prozessen zu Anwendungssystemen sowie Handlungsempfehlungen zur Virtualisierung.
Für Wissenschaftler und Studierende der Wirtschaftsinformatik zeigt das Buch neue Erkenntnisse einer anwendungsorientierten Referenzmodellierung. Für Praktiker liefert es eine methodisch fundierte Lösung für die aktuellen Transformationsbedarfe der Telekommunikationsindustrie. Christian Czarnecki arbeitet seit 2004 als Unternehmensberater und hat viele Telekommunikationsunternehmen bei deren Transformation begleitet. In 2013 erfolgte die Promotion zum Doktoringenieur an der Otto-von-Guericke-Universität Magdeburg.