Refine
Year of publication
- 2018 (169) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (59)
- Fachbereich Elektrotechnik und Informationstechnik (35)
- IfB - Institut für Bioengineering (34)
- INB - Institut für Nano- und Biotechnologien (23)
- Fachbereich Chemie und Biotechnologie (18)
- Fachbereich Luft- und Raumfahrttechnik (18)
- Fachbereich Energietechnik (15)
- Fachbereich Maschinenbau und Mechatronik (10)
- Fachbereich Bauingenieurwesen (8)
- Solar-Institut Jülich (4)
Has Fulltext
- no (169) (remove)
Language
- English (169) (remove)
Document Type
- Article (85)
- Conference Proceeding (62)
- Part of a Book (15)
- Book (3)
- Doctoral Thesis (2)
- Conference Poster (1)
- Working Paper (1)
Keywords
- Energy efficiency (2)
- Engineering optimization (2)
- MINLP (2)
- Pump System (2)
- Serious Game (2)
- Water (2)
- Actors (1)
- Agility (1)
- Antarctica (1)
- Awareness (1)
Retrofitting of existing parabolic trough collector power plants with molten salt tower systems
(2018)
On the flight performance impact of landing gear drag reduction methods for unmanned air vehicles
(2018)
The flight performance impact of three different landing gear configurations on a small, fixed-wing UAV is analyzed with a combination of RANS CFD calculations and an incremental flight performance algorithm. A standard fixed landing gear configuration is taken as a baseline, while the influence of retracting the landing gear or applying streamlined fairings is investigated. A retraction leads to a significant parasite drag reduction, while also fairings promise large savings. The increase in lift-to-drag ratio is reduced at high lift coefficients due to the influence of induced drag. All configurations are tested on three different design missions with an incremental flight performance algorithm. A trade-off study is performed using the retracted or faired landing gear's weight increase as a variable. The analysis reveals only small mission performance gains as the aerodynamic improvements are negated by weight penalties. A new workflow for decision-making is presented that allows to estimate if a change in landing gear configuration is beneficial for a small UAV.
A chip-based amperometric biosensor referring on using the bioelectrocatalytical amplification principle for the detection of low adrenaline concentrations is presented. The adrenaline biosensor has been prepared by modification of a platinum thin-film electrode with an enzyme membrane containing the pyrroloquinoline quinone-dependent glucose dehydrogenase and glutaraldehyde. Measuring conditions such as temperature, pH value, and glucose concentration have been optimized to achieve a high sensitivity and a low detection limit of about 1 nM adrenaline measured in phosphate buffer at neutral pH value. The response of the biosensor to different catecholamines has also been proven. Long-term stability of the adrenaline biosensor has been studied over 10 days. In addition, the biosensor has been successfully applied for adrenaline detection in human blood plasma for future biomedical applications. Furthermore, preliminary experiments have been carried to detect the adrenaline-concentration difference measured in peripheral blood and adrenal venous blood, representing the adrenal vein sampling procedure of a physician.
Reconstructive surgery and tissue replacements like ureters or bladders reconstruction have been recently studied, taking into account growth and remodelling of cells since living cells are capable of growing, adapting, remodelling or degrading and restoring in order to deform and respond to stimuli. Hence, shapes of ureters or bladders and their microstructure change during growth and these changes strongly depend on external stimuli such as training. We present the mechanical stimulation of smooth muscle cells in a tubular fibrin-PVDFA scaffold and the modelling of the growth of tissue by stimuli. To this end, mechanotransduction was performed with a kyphoplasty balloon catheter that was guided through the lumen of the tubular structure. The bursting pressure was examined to compare the stability of the incubated tissue constructs. The results showed the significant changes on tissues with training by increasing the burst pressure as a characteristic mechanical property and the smooth muscle cells were more oriented with uniformly higher density. Besides, the computational growth models also exhibited the accurate tendencies of growth of the cells under different external stimuli. Such models may lead to design standards for the better layered tissue structure in reconstructing of tubular organs characterized as composite materials such as intestines, ureters and arteries.