Refine
Year of publication
- 2011 (189) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (71)
- INB - Institut für Nano- und Biotechnologien (35)
- Fachbereich Elektrotechnik und Informationstechnik (31)
- IfB - Institut für Bioengineering (29)
- Fachbereich Chemie und Biotechnologie (22)
- Fachbereich Luft- und Raumfahrttechnik (16)
- Fachbereich Energietechnik (15)
- Fachbereich Maschinenbau und Mechatronik (12)
- Solar-Institut Jülich (11)
- Fachbereich Bauingenieurwesen (5)
Language
- English (189) (remove)
Document Type
- Article (130)
- Conference Proceeding (44)
- Part of a Book (8)
- Conference: Meeting Abstract (3)
- Book (2)
- Doctoral Thesis (2)
Keywords
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- plant scanner (2)
- Aktionskunst (1)
- Anastomose (1)
- Anastomosis (1)
- Biomechanics (1)
- Biomechanik (1)
- Bioreaktor (1)
- Blutzellenlagerung (1)
Purpose:
At 1.5 T, real-time MRI of joint movement has been shown to be feasible. However, 7 T, provides higher SNR and thus an improved potential for parallel imaging acceleration. The purpose of this work was to build an open, U-shaped eight-channel transmit/receive microstrip coil for 7 T MRI to enable high-resolution and real-time imaging of the moving ankle joint.
Methods:
A U-shaped eight-channel transmit/receive array for the human ankle was built.urn:x-wiley:00942405:mp3399:equation:mp3399-math-0001-parameters and urn:x-wiley:00942405:mp3399:equation:mp3399-math-0002-factor were measured. SAR calculations of different ankle postures were performed to ensure patient safety. Inhomogeneities in the transmit field consequent to the open design were compensated for by the use of static RF shimming. High-resolution and real-time imaging was performed in human volunteers.
Results:
The presented array showed good performance with regard to patient comfort and image quality. High acceleration factors of up to 4 are feasible without visible acceleration artifacts. Reasonable image homogeneity was achieved with RF shimming.
Conclusions:
Open, noncylindrical designs for transmit/receive coils are practical at 7 T and real-time imaging of the moving joint is feasible with the presented coil design.
In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit.