Refine
Year of publication
- 2013 (139) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (49)
- INB - Institut für Nano- und Biotechnologien (32)
- Fachbereich Chemie und Biotechnologie (24)
- IfB - Institut für Bioengineering (21)
- Fachbereich Wirtschaftswissenschaften (18)
- Fachbereich Elektrotechnik und Informationstechnik (13)
- Fachbereich Energietechnik (12)
- Sonstiges (6)
- Fachbereich Luft- und Raumfahrttechnik (5)
- Fachbereich Bauingenieurwesen (4)
Document Type
- Article (139) (remove)
Keywords
- Bacillus atrophaeus (1)
- Distorsion des oberen Sprunggelenks (1)
- Epithel (1)
- Fibroblast (1)
- Prozessabläufe (1)
- Prozessmodellierung (1)
- Prozessstandardisierung (1)
- Referenzmodellierung (1)
- Sprunggelenkorthesen (1)
- Wundheilung (1)
The concept of an injective affine embedding of the quantum states into a set of classical states, i.e., into the set of the probability measures on some measurable space, as well as its relation to statistically complete observables is revisited, and its limitation in view of a classical reformulation of the statistical scheme of quantum mechanics is discussed. In particular, on the basis of a theorem concerning a non-denseness property of a set of coexistent effects, it is shown that an injective classical embedding of the quantum states cannot be supplemented by an at least approximate classical description of the quantum mechanical effects. As an alternative approach, the concept of quasi-probability representations of quantum mechanics is considered.
Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers
(2013)
Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.