Refine
Year of publication
Document Type
- Article (5586)
- Conference Proceeding (1620)
- Book (1078)
- Part of a Book (548)
- Bachelor Thesis (297)
- Patent (172)
- Report (100)
- Doctoral Thesis (78)
- Other (77)
- Administrative publication (76)
- Part of Periodical (63)
- Lecture (30)
- Master's Thesis (20)
- Contribution to a Periodical (19)
- Review (17)
- Diploma Thesis (15)
- Working Paper (13)
- Course Material (9)
- Talk (7)
- Study Thesis (5)
Language
- German (5012)
- English (4801)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Spanish (3)
- nld (2)
- Italien (1)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (21)
- Studien- und Prüfungsordnung (21)
- Aachen / Fachhochschule Aachen (20)
- Änderungsordnung (20)
- Blitzschutz (18)
- Corporate Design (17)
- Elektromobilität (17)
- CAD (16)
- Finite-Elemente-Methode (16)
- Fotografie (16)
- civil engineering (14)
Institute
- Fachbereich Medizintechnik und Technomathematik (2052)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1138)
- Fachbereich Energietechnik (1104)
- Fachbereich Maschinenbau und Mechatronik (866)
- Fachbereich Chemie und Biotechnologie (847)
- Fachbereich Luft- und Raumfahrttechnik (776)
- Fachbereich Bauingenieurwesen (705)
- IfB - Institut für Bioengineering (686)
- INB - Institut für Nano- und Biotechnologien (613)
- Fachbereich Gestaltung (484)
- Solar-Institut Jülich (339)
- Fachbereich Architektur (174)
- FH Aachen (153)
- ECSM European Center for Sustainable Mobility (112)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (74)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (71)
- Nowum-Energy (70)
- Institut fuer Angewandte Polymerchemie (32)
- Sonstiges (24)
Nach drei Jahren ist der Anblick der beigen Kommode doch etwas langweilig geworden und es steht ein Tapetenwechsel an? Das ist noch lange kein Grund, neue Möbel kaufen zu müssen. Mit dem „BOBBI“-Regal lässt sich das Farbkonzept des Möbelstücks fortlaufend anpassen. Das reduzierte Grundgestell basiert auf einem einfachen Stecksystem und ermöglicht nicht nur einen schnellen, intuitiven Aufbau, sondern auch eine modulare Erweiterung des Regalsystems. Eintönig? Nein Danke! Zeitloses, langlebiges Design muss nicht schlicht und farblos sein! Der Schlüssel liegt in der Individualisierbarkeit. Mithilfe einer einfachen textilen Bespannungstechnik passt der Kunde das Gerüst nach seinen Vorstellungen an. Auf diese Weise kann der Charakter des Möbelstücks nicht nur farblich, sondern auch strukturell regelmäßig verändert werden und trägt zu einer nachhaltigen und achtsamen Raumgestaltung bei.
The mechanical behavior of the large intestine beyond the ultimate stress has never been investigated. Stretching beyond the ultimate stress may drastically impair the tissue microstructure, which consequently weakens its healthy state functions of absorption, temporary storage, and transportation for defecation. Due to closely similar microstructure and function with humans, biaxial tensile experiments on the porcine large intestine have been performed in this study. In this paper, we report hyperelastic characterization of the large intestine based on experiments in 102 specimens. We also report the theoretical analysis of the experimental results, including an exponential damage evolution function. The fracture energies and the threshold stresses are set as damage material parameters for the longitudinal muscular, the circumferential muscular and the submucosal collagenous layers. A biaxial tensile simulation of a linear brick element has been performed to validate the applicability of the estimated material parameters. The model successfully simulates the biomechanical response of the large intestine under physiological and non-physiological loads.
Edge-based and face-based smoothed finite element methods (ES-FEM and FS-FEM, respectively) are modified versions of the finite element method allowing to achieve more accurate results and to reduce sensitivity to mesh distortion, at least for linear elements. These properties make the two methods very attractive. However, their implementation in a standard finite element code is nontrivial because it requires heavy and extensive modifications to the code architecture. In this article, we present an element-based formulation of ES-FEM and FS-FEM methods allowing to implement the two methods in a standard finite element code with no modifications to its architecture. Moreover, the element-based formulation permits to easily manage any type of element, especially in 3D models where, to the best of the authors' knowledge, only tetrahedral elements are used in FS-FEM applications found in the literature. Shape functions for non-simplex 3D elements are proposed in order to apply FS-FEM to any standard finite element.
Retinal vessels are similar to cerebral vessels in their structure and function. Moderately low oscillation frequencies of around 0.1 Hz have been reported as the driving force for paravascular drainage in gray matter in mice and are known as the frequencies of lymphatic vessels in humans. We aimed to elucidate whether retinal vessel oscillations are altered in Alzheimer's disease (AD) at the stage of dementia or mild cognitive impairment (MCI). Seventeen patients with mild-to-moderate dementia due to AD (ADD); 23 patients with MCI due to AD, and 18 cognitively healthy controls (HC) were examined using Dynamic Retinal Vessel Analyzer. Oscillatory temporal changes of retinal vessel diameters were evaluated using mathematical signal analysis. Especially at moderately low frequencies around 0.1 Hz, arterial oscillations in ADD and MCI significantly prevailed over HC oscillations and correlated with disease severity. The pronounced retinal arterial vasomotion at moderately low frequencies in the ADD and MCI groups would be compatible with the view of a compensatory upregulation of paravascular drainage in AD and strengthen the amyloid clearance hypothesis.
This study addresses a proof-of-concept experiment with a biocompatible screen-printed carbon electrode deposited onto a biocompatible and biodegradable substrate, which is made of fibroin, a protein derived from silk of the Bombyx mori silkworm. To demonstrate the sensor performance, the carbon electrode is functionalized as a glucose biosensor with the enzyme glucose oxidase and encapsulated with a silicone rubber to ensure biocompatibility of the contact wires. The carbon electrode is fabricated by means of thick-film technology including a curing step to solidify the carbon paste. The influence of the curing temperature and curing time on the electrode morphology is analyzed via scanning electron microscopy. The electrochemical characterization of the glucose biosensor is performed by amperometric/voltammetric measurements of different glucose concentrations in phosphate buffer. Herein, systematic studies at applied potentials from 500 to 1200 mV to the carbon working electrode (vs the Ag/AgCl reference electrode) allow to determine the optimal working potential. Additionally, the influence of the curing parameters on the glucose sensitivity is examined over a time period of up to 361 days. The sensor shows a negligible cross-sensitivity toward ascorbic acid, noradrenaline, and adrenaline. The developed biocompatible biosensor is highly promising for future in vivo and epidermal applications.
„Work Habitat“ ist eine markenorientierte Officelösung, die auf skalierbare Weise mit einem Start-up mitwächst und in Kooperation mit dem Unternehmen academa GmbH entstanden ist. Diese Brand Experience fördert Teambuilding und Identifikation mit dem Unternehmen. Sie passt sich an die Teammitglieder an, indem sie einen ganzheitlichen Blick auf das Office-System bewahrt. Ferner stellt sie eine nahtlose Verbindung digitaler und analoger Arbeitswelten dar und bietet eine einladende Umgebung verschiedener Arten zu Arbeiten an: von Deep-Focus bis zur kooperativen Zusammenarbeit und der Anregung zwangloser Begegnungen. Die modularen Komponenten können trotz Veränderungen, Umzügen oder unerwartet rasanten Entwicklungen nachhaltig und flexibel eingesetzt werden. Eine schnelllebige Welt erfordert eine angebrachte, sich ihr anpassende New-Work-Umgebung.
Kindertagesstätten bieten Kleinkindern den Zugang zu unbeschwertem und spielerischem Lernen. Was also, wenn schon der Eingangsbereich die Reizüberflutung bereit hält, der Stauraum der Entfaltung der Kinder nicht gerecht wird und ihre Eigenständigkeit ungefördert bleibt? Es kommt zu unzufriedenen Kindern und Frustration aller Beteilligten. "KIWA" ist das Garderobensystem für Kinder zur Stärkung der heranwachsenden Selbstständigkeit. Mithilfe von persönlichen Wiedererkennungsmerkmalen wird Eigenverantwortung geschult. Leicht und sicher zu erreichender Stauraum sorgt für Ordnung. Spielerisches lernen trotz Ordnung.
Digital twins enable the modeling and simulation of real-world entities
(objects, processes or systems), resulting in improvements in the associated value
chains. The emerging field of quantum computing holds tremendous promise for
evolving this virtualization towards Quantum (Digital) Twins (QDT) and
ultimately Quantum Twins (QT). The quantum (digital) twin concept is not a
contradiction in terms - but instead describes a hybrid approach that can be
implemented using the technologies available today by combining classical
computing and digital twin concepts with quantum processing. This paper
presents the status quo of research and practice on quantum (digital) twins. It also
discuses their potential to create competitive advantage through real-time
simulation of highly complex, interconnected entities that helps companies better
address changes in their environment and differentiate their products and
services.
Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize.