Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (2074)
- Fachbereich Elektrotechnik und Informationstechnik (1184)
- Fachbereich Wirtschaftswissenschaften (1158)
- Fachbereich Energietechnik (1115)
- Fachbereich Chemie und Biotechnologie (912)
- Fachbereich Maschinenbau und Mechatronik (868)
- Fachbereich Luft- und Raumfahrttechnik (798)
- Fachbereich Bauingenieurwesen (711)
- IfB - Institut für Bioengineering (690)
- INB - Institut für Nano- und Biotechnologien (615)
Language
- German (5114)
- English (4909)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Spanish (3)
- Dutch (2)
- Italian (1)
Document Type
- Article (5646)
- Conference Proceeding (1639)
- Book (1079)
- Part of a Book (559)
- Bachelor Thesis (327)
- Patent (174)
- Report (101)
- Doctoral Thesis (79)
- Other (76)
- Administrative publication (76)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (23)
Zugriffsart
- campus (2147)
- weltweit (1860)
- bezahl (766)
- fachbereichsweit (FB4) (34)
Prolonged operations close to small solar system bodies require a sophisticated control logic to minimize propellant mass and maximize operational efficiency. A control logic based on Discrete Mechanics and Optimal Control (DMOC) is proposed and applied to both conventionally propelled and solar sail spacecraft operating at an arbitrarily shaped asteroid in the class of Itokawa. As an example, stand-off inertial hovering is considered, recently identified as a challenging part of the Marco Polo mission. The approach is easily extended to stand-off orbits. We show that DMOC is applicable to spacecraft control at small objects, in particular with regard to the fact that the changes in gravity are exploited by the algorithm to optimally control the spacecraft position. Furthermore, we provide some remarks on promising developments.
The chemical imaging sensor was applied to in-situ pH imaging of the solution in the vicinity of a corroding surface of stainless steel under potentiostatic polarization. A test piece of polished stainless steel was placed on the sensing surface leaving a narrow gap filled with artificial seawater and the stainless steel was corroded under polarization. The pH images obtained during polarization showed correspondence between the region of lower pH and the site of corrosion. It was also found that the pH value in the gap became as low as 2 by polarization, which triggered corrosion.
Multi-analyte biosensors may offer the opportunity to perform cost-effective and rapid analysis with reduced sample volume, as compared to electrochemical biosensing of each analyte individually. This work describes the development of an enzyme-based biosensor system for multi-parametric determination of four different organic acids. The biosensor array comprises five working electrodes for simultaneous sensing of ethanol, formate, d-lactate, and l-lactate, and an integrated counter electrode. Storage stability of the biosensor was evaluated under different conditions (stored at +4 °C in buffer solution and dry at −21 °C, +4 °C, and room temperature) over a period of 140 days. After repeated and regular application, the individual sensing electrodes exhibited the best stability when stored at −21 °C. Furthermore, measurements in silage samples (maize and sugarcane silage) were conducted with the portable biosensor system. Comparison with a conventional photometric technique demonstrated successful employment for rapid monitoring of complex media.