Refine
Year of publication
- 2006 (54) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (29)
- Fachbereich Bauingenieurwesen (12)
- INB - Institut für Nano- und Biotechnologien (5)
- Fachbereich Maschinenbau und Mechatronik (4)
- IfB - Institut für Bioengineering (4)
- Fachbereich Wirtschaftswissenschaften (3)
- Fachbereich Gestaltung (2)
- FH Aachen (1)
- Fachbereich Luft- und Raumfahrttechnik (1)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (1)
Has Fulltext
- yes (54) (remove)
Language
- English (31)
- German (21)
- Portuguese (1)
- Spanish (1)
Document Type
- Conference Proceeding (41)
- Diploma Thesis (3)
- Lecture (3)
- Article (2)
- Course Material (2)
- Other (1)
- Part of a Periodical (1)
- Working Paper (1)
Keywords
- Biosensor (23)
- CAD (3)
- Technische Mechanik (3)
- Bauingenieurwesen (2)
- Bauplanung (2)
- Führung (2)
- Leadership (2)
- Motivation (2)
- Rapid Prototyping (2)
- Rapid prototyping (2)
Is part of the Bibliography
- no (54)
Study of swift heavy ion modified conduction polymer composites for application as gas sensor
(2006)
A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.
Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell
(2006)
A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors.
Ziel und Inhalt dieser Arbeit ist das Design eines Harlekin-Charakters und die Darstellung seiner Ausdrucksskala. Der Schwerpunkt liegt dabei auf dem Studium der Gesichtsmuskeln, ihrer Formensprache und ihrer Relation zu den 6 Grundemotionen Traurigkeit, Ärger, Angst, Freude, Ekel und Überraschung (nach dem Modell von Paul Ekman). Alle 6 Emotionen sind in verschiedenen Intensitätsgraden und Variationen behandelt, wobei die Emotion der Freude aufgrund ihrer engen Bindung zum Harlekin-Charakter vergleichsweise umfassender bearbeitet wurde. Das Endergebnis stellt eine Bildreihe von ca. 50 Ausdrücken und eine Abhandlung über Gesichtsmuskulatur und -ausdruck, dessen Relation zu den Emotionen und den Hintergrund des Harlekincharakters dar. Die Illustrationen wurden unter Verwendung der 3D-Technologie von Maya 7.0 und ZBrush 2.0 ausgeführt.