Refine
Year of publication
- 2012 (333) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (72)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Elektrotechnik und Informationstechnik (41)
- Fachbereich Chemie und Biotechnologie (40)
- INB - Institut für Nano- und Biotechnologien (32)
- IfB - Institut für Bioengineering (31)
- Fachbereich Bauingenieurwesen (30)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
Document Type
- Article (130)
- Conference Proceeding (89)
- Part of a Book (36)
- Book (26)
- Conference: Meeting Abstract (17)
- Patent (12)
- Part of a Periodical (9)
- Doctoral Thesis (7)
- Report (4)
- Habilitation (1)
Keywords
- Elektromobilität (7)
- Elektrofahrzeug (5)
- Energieversorgungsnetz (5)
- Kraftfahrzeugelektronik (5)
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (2)
- Elektromobilität; Elektrofahrzeug; Energieversorungsnetz; Kraftfahrzeugtechnik (2)
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
Partikelmesstechnik
(2012)
Der Schutz von Produkten vor der Kontamination durch Partikel gilt als eine zentrale Aufgabe der Reinraumtechnik. Da es dabei um Kontaminationseffekte weit unterhalb der visuellen Wahrnehmbarkeit geht, braucht es leistungsfähige Verfahren, um die Messgröße „Partikelkontamination“ über den gesamten Bereich, den Anwender fordern, präzise zu bestimmen. Neben der Partikelhäufigkeit ist dabei die Größe der Partikel, die sowohl das Transportverhalten wie auch die mögliche Wirkung auf das Produkt beeinflusst, von entscheidender Bedeutung. Ferner kann es für die Ermittlung von Kontaminationsquellen von Interesse sein, die Form und die chemische Natur der Partikel zu bestimmen (z. B. textile Fasern, Metallabrieb, flüssige Tröpfchen). Die Partikelhäufigkeit wird üblicherweise als Konzentration, d. h. bezogen auf das analysierte Gasvolumen angegeben. Bei den in reinen Technologien üblichen niedrigen Konzentrationen dient als Häufigkeitsmaß die Partikelanzahlkonzentration, also die Partikelanzahl pro Volumeneinheit des Trägermediums.
Mit Gesetz vom 29.7.2009 (BGBl 2009 I S. 2355) hat der deutsche Gesetzgeber die EU-Verbraucherkreditrichtlinie 2008/48/EG vom 23.4.2008 NWB PAAAD-28762 in nationales Recht umgesetzt. In diesem Gesetz ist auch der Immobiliardarlehensvertrag neu geregelt worden. Auf diese besondere Kreditform sind grds. die Vorschriften zum Verbraucherkredit anzuwenden, so dass der Darlehensgeber auch im Fall einer Immobilienfinanzierung zu vorvertraglicher Information des Verbrauchers verpflichtet ist. Beim finanzierten Immobilienerwerb werden Veräußerer und kreditgebende Bank häufig in Abstimmung und Zusammenarbeit tätig, so dass für die Bank besondere Aufklärungspflichten gegenüber dem Verbraucher entstehen. Im Fall der Verletzung dieser Pflichten drohen ihr Schadensersatzansprüche oder ein Widerrufsrecht des Verbrauchers.
A variety of transition metals, e.g., copper, zinc, cadmium, lead, etc. are widely used in industry as components for wires, coatings, alloys, batteries, paints and so on. The inevitable presence of transition metals in industrial processes implies the ambition of developing a proper analytical technique for their adequate monitoring. Most of these elements, especially lead and cadmium, are acutely toxic for biological organisms. Quantitative determination of these metals at low activity levels in different environmental and industrial samples is therefore a vital task. A promising approach to achieve an at-side or on-line monitoring on a miniaturized and cost efficient way is the combination of a common potentiometric sensor array with heavy metal-sensitive thin-film materials, like chalcogenide glasses and polymeric materials, respectively.
The chemical imaging sensor is a chemical sensor which is capable of visualizing the spatial distribution of chemical species in sample solution. In this study, a novel measurement system based on the chemical imaging sensor was developed to observe the inside of a Y-shaped microfluidic channel while injecting two sample solutions from two branches. From the collected chemical images, it was clearly observed that the injected solutions formed laminar flows in the microfluidic channel. In addition, ion diffusion across the laminar flows was observed. This label-free method can acquire quantitative data of ion distribution and diffusion in microfluidic devices, which can be used to determine the diffusion coefficients, and therefore, the molecular weights of chemical species in the sample solution.
This work describes the novel combination of the light-addressable electrode (LAE) and the light-addressable potentiometric sensor (LAPS) into a microsystem set-up. Both the LAE as well as the LAPS shares the principle of addressing the active spot by means of a light beam. This enables both systems to manipulate resp. to detect an analyte with a high spatial resolution. Hence, combining both principles into a single set-up enables the active stimulation e.g., by means of electrolysis and a simultaneous observation e.g., the response of an entrapped biological cell by detection of extracellular pH changes. The work will describe the principles of both technologies and the necessary steps to integrate them into a single set-up. Furthermore, examples of application and operation of such systems will be presented.
Deoxyribonucleic acid (DNA) and protein recognition are now standard tools in biology. In addition, the special optical properties of microsphere resonators expressed by the high quality factor (Q-factor) of whispering gallery modes (WGMs) or morphology dependent resonances (MDRs) have attracted the attention of the biophotonic community. Microsphere-based biosensors are considered as powerful candidates to achieve label-free recognition of single molecules due to the high sensitivity of their WGMs. When the microsphere surface is modified with biomolecules, the effective refractive index and the effective size of the microsphere change resulting in a resonant wavelength shift. The transverse electric (TE) and the transverse magnetic (TM) elastic light scattering intensity of electromagnetic waves at 600 and 1400 nm are numerically calculated for DNA and unspecific binding of proteins to the microsphere surface. The effect of changing the optical properties was studied for diamond (refractive index 2.34), glass (refractive index 1.50), and sapphire (refractive index 1.75) microspheres with a 50 µm radius. The mode spacing, the linewidth of WGMs, and the shift of resonant wavelength due to the change in radius and refractive index, were analyzed by numerical simulations. Preliminary results of unspecific binding of biomolecules are presented. The calculated shift in WGMs can be used for biomolecules detection.
Der Deutsche Bundestag und Bundesrat haben am 2.3.2012 bzw. 30.3.2012 das Gesetz gegen Kostenfallen im Internet verabschiedet, das am 1.8.2012 in Kraft treten wird. Hiermit hat der deutsche Gesetzgeber einen ersten Schritt getan, um die neue EU-Verbraucherrechterichtlinie vom 25.10.2011 (2011/83/EU, ABl L 304/64) in nationales Recht umzusetzen. Mit dieser Umsetzung ist das drängendste Problem der Kosten- und Abo-Fallen im elektronischen Geschäftsverkehr aus dem Gesamtpaket der Verbraucherrechterichtlinie herausgelöst und in dem neugefassten § 312g BGB behandelt worden. Eile bei der Umsetzung war hier geboten, weil unseriöse Unternehmen im elektronischen Rechtsverkehr zunehmend und in großem Umfang gegenüber ihren Kunden durch irreführende Gestaltungen ihrer Internetseiten verschleiern, dass die angebotenen Leistungen entgeltpflichtig sind.
Many applications in computational science and engineering require the computation of eigenvalues and vectors of dense symmetric or Hermitian matrices. For example, in DFT (density functional theory) calculations on modern supercomputers 10% to 30% of the eigenvalues and eigenvectors of huge dense matrices have to be calculated. Therefore, performance and parallel scaling of the used eigensolvers is of upmost interest. In this article different routines of the linear algebra packages ScaLAPACK and Elemental for parallel solution of the symmetric eigenvalue problem are compared concerning their performance on the BlueGene/P supercomputer. Parameters for performance optimization are adjusted for the different data distribution methods used in the two libraries. It is found that for all test cases the new library Elemental which uses a two-dimensional element by element distribution of the matrices to the processors shows better performance than the old ScaLAPACK library which uses a block-cyclic distribution.