Refine
Year of publication
- 2014 (301) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- Fachbereich Chemie und Biotechnologie (46)
- Fachbereich Elektrotechnik und Informationstechnik (43)
- Fachbereich Wirtschaftswissenschaften (41)
- Fachbereich Energietechnik (40)
- INB - Institut für Nano- und Biotechnologien (35)
- IfB - Institut für Bioengineering (25)
- Fachbereich Maschinenbau und Mechatronik (21)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Bauingenieurwesen (12)
Document Type
- Article (142)
- Conference Proceeding (67)
- Part of a Book (30)
- Book (21)
- Conference: Meeting Abstract (15)
- Report (8)
- Other (6)
- Bachelor Thesis (3)
- Patent (2)
- Part of a Periodical (2)
Keywords
Selective Laser Melting (SLM) is one of the Additive Manufacturing (AM) technologies applicable for producing complex geometries which are typically expensive or difficult to fabricate using conventional methods. This process has been extensively investigated experimentally for various metals and the fabrication process parameters have been established for different applications; however, fabricating 3D glass objects using SLM technology has remained a challenge so far although it could have many applications. This paper presents a summery on various experimental evaluations of a material database incorporating the build parameters of glass powder using the SLM process for jewelry applications.
Generation Y
(2014)
Mehrwert
(2014)
A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) realized a higher spatial resolution of chemical imaging. In this method, a modulated light probe, which generates the alternating photocurrent signal, is surrounded by a ring of constant light, which suppresses the lateral diffusion of photocarriers by enhancing recombination. A device simulation verified that a higher spatial resolution could be obtained by adjusting the gap between the modulated and constant light. It was also found that a higher intensity and a longer wavelength of constant light was more effective. However, there exists a tradeoff between the spatial resolution and the amplitude of the photocurrent, and thus, the signal-to-noise ratio. A tilted incidence of constant light was applied, which could achieve even higher resolution with a smaller loss of photocurrent.
A semiconductor field-effect device has been used for an enzymatically catalyzed degradation of biopolymers for the first time. This novel technique is capable to monitor the degradation process of multiple samples in situ and in real-time. As model system, the degradation of the biopolymer poly(D, L-lactic acid) has been monitored in the degradation medium containing the enzyme lipase from Rhizomucor miehei. The obtained results demonstrate the potential of capacitive field-effect sensors for degradation studies of biodegradable polymers.