Refine
Year of publication
- 2017 (154) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (61)
- IfB - Institut für Bioengineering (32)
- INB - Institut für Nano- und Biotechnologien (26)
- Fachbereich Elektrotechnik und Informationstechnik (25)
- Fachbereich Luft- und Raumfahrttechnik (22)
- Fachbereich Energietechnik (14)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Maschinenbau und Mechatronik (10)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (10)
- Fachbereich Bauingenieurwesen (7)
Language
- English (154) (remove)
Document Type
- Article (72)
- Conference Proceeding (66)
- Part of a Book (12)
- Other (2)
- Book (1)
- Patent (1)
Keywords
- MASCOT (2)
- 3D nonlinear finite element model (1)
- Acceptance tests (1)
- Automated Optimization (1)
- Autonomous mobile robots (1)
- Biomolecular logic gate (1)
- CNOT (1)
- Capacitive field-effect (1)
- Chemical images (1)
- Chemical sensor (1)
Is part of the Bibliography
- no (154)
Enzyme-based logic gates and circuits - analytical applications and interfacing with electronics
(2017)
The paper is an overview of enzyme-based logic gates and their short circuits, with specific examples of Boolean AND and OR gates, and concatenated logic gates composed of multi-step enzyme-biocatalyzed reactions. Noise formation in the biocatalytic reactions and its decrease by adding a “filter” system, converting convex to sigmoid response function, are discussed. Despite the fact that the enzyme-based logic gates are primarily considered as components of future biomolecular computing systems, their biosensing applications are promising for immediate practical use. Analytical use of the enzyme logic systems in biomedical and forensic applications is discussed and exemplified with the logic analysis of biomarkers of various injuries, e.g., liver injury, and with analysis of biomarkers characteristic of different ethnicity found in blood samples on a crime scene. Interfacing of enzyme logic systems with modified electrodes and semiconductor devices is discussed, giving particular attention to the interfaces functionalized with signal-responsive materials. Future perspectives in the design of the biomolecular logic systems and their applications are discussed in the conclusion.
A graphene-functionalized carbon fiber electrode was modified with adsorbed polyethylenimine to introduce amino functionalities and then with trigonelline and 4-carboxyphenylboronic acid covalently bound to the amino groups. The trigonelline species containing quarterized pyridine groups produced positive charge on the electrode surface regardless of the pH value, while the phenylboronic acid species were neutral below pH 8 and negatively charged above pH 9 (note that their pKa=8.4). The total charge on the monolayer-modified electrode was positive at the neutral pH and negative at pH > 9. Note that 4-carboxyphenylboronic acid was attached to the electrode surface in molar excess to trigonelline, thus allowing the negative charge to dominate on the electrode surface at basic pH. Negatively charged fluorescent dye-labeled insulin (insulin-FITC) was loaded on the modified electrode surface at pH 7.0 due to its electrostatic attraction to the positively charged interface. The local pH in close vicinity to the electrode surface was increased to ca. 9–10 due to consumption of H+ ions upon electrochemical reduction of oxygen proceeding at the potential of −1.0 V (vs. Ag/AgCl) applied on the modified electrode. The process resulted in recharging of the electrode surface to the negative value due to the formation of the negative charge on the phenylboronic acid groups, thus resulting in the electrostatic repulsion of insulin-FITC and stimulating its release from the electrode surface. The insulin release was characterized by fluorescence spectroscopy (using the FITC-labeled insulin), by electrochemical measurements on an iridium oxide, IrOx, electrode and by mass spectrometry. The graphene-functionalized carbon fiber electrode demonstrated significant advantages in the signal-stimulated insulin release comparing with the carbon fiber electrode without the graphene species.
Combined with the use of renewable energy sources for
its production, Hydrogen represents a possible alternative gas
turbine fuel for future low emission power generation. Due to
its different physical properties compared to other fuels such
as natural gas, well established gas turbine combustion
systems cannot be directly applied for Dry Low NOx (DLN)
Hydrogen combustion. This makes the development of new
combustion technologies an essential and challenging task
for the future of hydrogen fueled gas turbines.
The newly developed and successfully tested “DLN
Micromix” combustion technology offers a great potential to
burn hydrogen in gas turbines at very low NOx emissions.
Aiming to further develop an existing burner design in terms
of increased energy density, a redesign is required in order to
stabilise the flames at higher mass flows and to maintain low
emission levels.
For this purpose, a systematic design exploration has
been carried out with the support of CFD and optimisation
tools to identify the interactions of geometrical and design
parameters on the combustor performance. Aerodynamic
effects as well as flame and emission formation are observed
and understood time- and cost-efficiently. Correlations
between single geometric values, the pressure drop of the
burner and NOx production have been identified as a result.
This numeric methodology helps to reduce the effort of
manufacturing and testing to few designs for single
validation campaigns, in order to confirm the flame stability
and NOx emissions in a wider operating condition field.