Refine
Year of publication
- 2017 (153) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (60)
- IfB - Institut für Bioengineering (32)
- INB - Institut für Nano- und Biotechnologien (26)
- Fachbereich Elektrotechnik und Informationstechnik (25)
- Fachbereich Luft- und Raumfahrttechnik (22)
- Fachbereich Energietechnik (14)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Maschinenbau und Mechatronik (10)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (10)
- Fachbereich Bauingenieurwesen (7)
Has Fulltext
- no (153) (remove)
Language
- English (153) (remove)
Document Type
- Article (72)
- Conference Proceeding (65)
- Part of a Book (12)
- Other (2)
- Book (1)
- Patent (1)
Keywords
- MASCOT (2)
- 3D nonlinear finite element model (1)
- Acceptance tests (1)
- Automated Optimization (1)
- Autonomous mobile robots (1)
- Biomolecular logic gate (1)
- CNOT (1)
- Capacitive field-effect (1)
- Chemical images (1)
- Chemical sensor (1)
Is part of the Bibliography
- no (153)
The invention pertains to a CellDrum electrode arrangement for measuring mechanical stress, comprising a mechanical holder (1 ) and a non-conductive membrane (4), whereby the membrane (4) is at least partially fixed at its circumference to the mechanical holder (1), keeping it in place when the membrane (4) may bend due to forces acting on the membrane (4), the mechanical holder (1) and the membrane (4) forming a container, whereby the membrane (1) within the container comprises an cell- membrane compound layer or biological material (3) adhered to the deformable membrane 4 which in response to stimulation by an agent may exert mechanical stress to the membrane (4) such that the membrane bending stage changes whereby the container may be filled with an electrolyte, whereby an electric contact (2) is arranged allowing to contact said electrolyte when filled into to the container, whereby within a predefined geometry to the fixing of the membrane (4) an electrode (7) is arranged, whereby the electrode (7) is electrically insulated with respect to the electric contact (2) as well as said electrolyte, whereby mechanical stress due to an agent may be measured as a change in capacitance.
The Pharmacokinetics and Metabolism of Lumiracoxib in Chimeric Humanized and Murinized FRG Mice
(2017)
Genetically humanized mice for proteins involved in drug metabolism and toxicity and mice engrafted with human hepatocytes are emerging as promising in vivo models for improved prediction of the pharmacokinetic, drug–drug interaction, and safety characteristics of compounds in humans. This is an overview on the genetically humanized and chimeric liver-humanized mouse models, which are illustrated with examples of their utility in drug metabolism and toxicity studies. The models are compared to give guidance for selection of the most appropriate model by highlighting advantages and disadvantages to be carefully considered when used for studies in drug discovery and development.
The capacitive electrolyte–insulator–semiconductor (EIS) structure is a typical device based on a field-effect sensor platform. With a simple silicon-based structure, EIS have been useful for several sensing applications, especially with incorporation of nanostructured films to modulate the ionic transport and the flat-band potential. In this paper, we report on ion transport and changes in flat-band potential in EIS sensors made with layer-by-layer films containing poly(amidoamine) (PAMAM) dendrimer and single-walled carbon nanotubes (SWNTs) adsorbed on p-Si/SiO 2 /Ta 2 O 5 chips with an Al ohmic contact. The impedance spectra were fitted using an equivalent circuit model, from which we could determine parameters such as the double-layer capacitance. This capacitance decreased with the number of bilayers owing to space charge accumulated at the electrolyte–insulator interface, up to three PAMAM/SWNTs bilayers, after which it stabilized. The charge-transfer resistance was also minimum for three bilayers, thus indicating that this is the ideal architecture for an optimized EIS performance. The understanding of the influence of nanostructures and the fine control of operation parameters pave the way for optimizing the design and performance of new EIS sensors.
ICSs (Industrial Control Systems) and its subset SCADA systems (Supervisory Control and Data Acquisition) are getting exposed to a constant stream of new threats. The increasing importance of IT security in ICS requires viable methods to assess the security of ICS, its individual components, and its protocols. This paper presents a security analysis with focus on the communication protocols of a single PLC (Programmable Logic Controller). The PLC, a Beckhoff CX2020, is examined and new vulnerabilities of the system are revealed. Based on these findings recommendations are made to improve security of the Beckhoff system and its protocols.