Refine
Year of publication
Institute
- INB - Institut für Nano- und Biotechnologien (586) (remove)
Has Fulltext
- no (586) (remove)
Document Type
- Article (523)
- Conference Proceeding (41)
- Part of a Book (9)
- Doctoral Thesis (4)
- Book (3)
- Patent (3)
- Other (2)
- Report (1)
Keywords
In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed.
Characterisation of polymeric materials as passivation layer for calorimetric H2O2 gas sensors
(2012)
Calorimetric gas sensors for monitoring the H₂O₂ concentration at elevated temperatures in industrial sterilisation processes have been presented in previous works. These sensors are built up in form of a differential set-up of a catalytically active and passive temperature-sensitive structure. Although, various types of catalytically active dispersions have been studied, the passivation layer has to be established and therefore, chemically as well as physically characterised. In the present work, fluorinated ethylene propylene (FEP), perfluoralkoxy (PFA) and epoxy-based SU-8 photoresist as temperature-stable polymeric materials have been investigated for sensor passivation in terms of their chemical inertness against H₂O₂, their hygroscopic properties as well as their morphology. The polymeric materials were deposited via spin-coating on the temperature-sensitive structure, wherein spin-coated FEP and PFA show slight agglomerates. However, they possess a low absorption of humidity due to their hydrophobic surface, whereas the SU-8 layer has a closed surface but shows a slightly higher absorption of water. All of them were inert against gaseous H₂O₂ during the characterisation in H₂O₂ atmosphere that demonstrates their suitability as passivation layer for calorimetric H₂O₂ gas sensors.
Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3–12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off.
Label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization/denaturation by means of an array of individually addressable field-effect-based nanoplate silicon-on-insulator (SOI) capacitors modified with gold nanoparticles (Au-NP) is investigated. The proposed device detects charge changes on Au-NP/DNA hybrids induced by the hybridization or denaturation event. DNA hybridization was performed in a high ionic-strength solution to provide a high hybridization efficiency. On the other hand, to reduce the screening of the DNA charge by counter ions and to achieve a high sensitivity, the sensor signal induced by the hybridization and denaturation events was measured in a low ionic-strength solution. High sensor signals of about 120, 90, and 80 mV were registered after the DNA hybridization, denaturation, and re-hybridization events, respectively. Fluorescence microscopy has been applied as reference method to verify the DNA immobilization, hybridization, and denaturation processes. An electrostatic charge-plane model for potential changes at the gate surface of a nanoplate field-effect sensor induced by the DNA hybridization has been developed taking into account both the Debye length and the distance of the DNA charge from the gate surface.
A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.
In this article, we report on the heat-transfer resistance at interfaces as a novel, denaturation-based method to detect single-nucleotide polymorphisms in DNA. We observed that a molecular brush of double-stranded DNA grafted onto synthetic diamond surfaces does not notably affect the heat-transfer resistance at the solid-to-liquid interface. In contrast to this, molecular brushes of single-stranded DNA cause, surprisingly, a substantially higher heat-transfer resistance and behave like a thermally insulating layer. This effect can be utilized to identify ds-DNA melting temperatures via the switching from low- to high heat-transfer resistance. The melting temperatures identified with this method for different DNA duplexes (29 base pairs without and with built-in mutations) correlate nicely with data calculated by modeling. The method is fast, label-free (without the need for fluorescent or radioactive markers), allows for repetitive measurements, and can also be extended toward array formats. Reference measurements by confocal fluorescence microscopy and impedance spectroscopy confirm that the switching of heat-transfer resistance upon denaturation is indeed related to the thermal on-chip denaturation of DNA.
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the currentvoltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.
In this contribution, we focus on the detection of toxic gases with living eukaryotic cells. A cell-based gas sensor system, able to measure the effects of direct exposure of gases to cells in real-time, was set up. Impedance data as well as oxygen consumption of Chinese hamster lung fibroblast cells (V79) were analysed upon exposure to carbon monoxide (CO). The CO (diluted in wet synthetic air) affects the cell respiration as indicated by an attenuated respiration signal after the CO exposure as well as an instant increase of the capacitive part of the impedance signal during the gas exposure.
Es wurde ein automatisiertes, computerunterstütztes Testsystem für die Funktionsprüfung und Charakterisierung von (bio-)chemischen Sensoren auf Waferebene entwickelt und in einen konventionellen Spitzenmessplatz integriert. Das System ermöglicht die Charakterisierung und Identifizierung „funktionstauglicher“ Sensoren bereits auf Waferebene zwischen den einzelnen Herstellungsschritten, wodurch weitere, bisher übliche Verarbeitungsschritte wie das Fixieren, Bonden und Verkapseln für die defekten oder nicht funktionstauglichen Sensorstrukturen entfällt. Außerdem bietet eine speziell entworfene miniaturisierte Durchflussmesszelle die Möglichkeit, bereits auf Waferlevel die Sensitivität, Drift, Hysterese und Ansprechzeit der (bio-)chemischen Sensoren zu charakterisieren. Das System wurde exemplarisch mit kapazitiven, pH-sensitiven EIS- (Elektrolyt-Isolator-Silizium) Strukturen und ISFET- (ionensensitiver Feldeffekttransistor) Strukturen mit verschiedenen Geometrien und Gate-Layouts getestet.
Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry
(2010)
A calorimetric gas sensor is presented for the monitoring of gas-phase H2O2 at elevated temperature during sterilization processes in aseptic food industry. The sensor consists of two temperature-sensitive thin-film resistances built up on a polyimide foil with a thickness of 25 μm, which are passivated with a layer of SU-8 photo resist and catalytically activated with manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilizes the elevated temperature of an evaporated H2O2 aerosol. In an experimental set-up, the sensor has shown a sensitivity of 4.78 °C/(%v/v) in a H2O2 concentration range of 0 to 10% v/v at an evaporation temperature of 240 ∘C. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied evaporation temperatures of the gas stream. The sensor characterization demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of sterilization processes.
Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach of read out in a light-addressable potentiometric sensor (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device which allows fast and flexible generation of light patterns. With the help of these light patterns the sensor surface of the LAPS device can be read out sequentially in a raster like scheme (scanning LAPS). The DLP approach has several advantages compared to conventional scanning LAPS set-ups, e.g., the spot size, the shape and the intensity of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of measurement.
In aseptischen Abfüllsystemen wird Wasserstoffperoxid in der Gasphase aufgrund der stark oxidativen Wirkung zur Packstoffentkeimung eingesetzt. Dabei wird die Effizienz der Entkeimung im Wesentlichen von der vorliegenden H2O2-Konzentration im Packstoff bestimmt. Zur Inline-Überwachung der H2O2-Konzentration wurde ein kalorimetrischer Gassensor auf Basis einer flexiblen Polyimidfolie aus temperatursensitiven Dünnschicht-Widerständen und Mangan(IV)-oxid als katalytische Transducerschicht realisiert. Der Sensor weist ein lineares Ansprechverhalten mit einer Sensitivität von 7,15 °C/Vol.-% in einem H2O2-Konzentrationsbereich von 0 bis 8 Vol.-% auf. Weiterhin wurde zur Auslesung des Sensorsignals eine RFID-Elektronik, bestehend aus einem Sensor-Tag und einer Sende-/Empfangseinheit ausgelegt, sowie eine Abfolge des Messzyklus aufgestellt. Im weiteren Verlauf soll der kalorimetrische Gassensor mit der RFID-Elektronik gekoppelt und in eine Testverpackung zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen implementiert werden.
Ein lichtadressierbarer potentiometrischer Sensor (LAPS) kann die Konzentration eines oder mehrerer Analyten ortsaufgelöst auf der Sensoroberfläche nachweisen. Dazu wird mit einer modulierten Lichtquelle die Halbleiterstruktur des zu untersuchenden Bereiches angeregt und ein entsprechender Photostrom ausgelesen. Durch gleichzeitige Anregung mehrere Bereiche durch Lichtquellen mit unterschiedlichen Modulationsfrequenzen können diese auch zeitgleich ausgelesen werden. Mit der neuen, hier vorgestellten Ansteuerungselektronik integriert in einem "Field Programmable Gate Array" (FPGA) ist es möglich, mehrere Leuchtquellen gleichzeitig mit unterschiedlichen, während der Laufzeit festlegbaren Frequenzen, Phasen und Lichtintensitäten zu betreiben. Somit kann das Frequenzverhalten des Sensors untersucht und die Konzentration des Analyten über das Oberflächenpotential mit Hilfe von Strom/Spannungs-Kurven und Phase/Spannungs-Kurven bestimmt werden.
Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte–insulator–semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10−6 to 10−2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10−6 to 10−2 mol/l for Pb2+, respectively.
A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.
Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.
A new approach for a label-free electrical detection of DNA hybridization and denaturation using an array of individually addressable field-effect nanoplate SOI (silicon-on-insulator) capacitors functionalized with gold nanoparticles is presented. By using a constant-capacitance measuring setup in a differential mode, signal changes of ∼110 mV and ∼70 mV have been registered after the DNA hybridization and denaturation events, respectively.
The development of new interfaces for (bio-)chemical sensors requires comprehensive analyses and testing. The light-addressable potentiometric sensor (LAPS) can be used as a platform to investigate the sensitivity of a newly developed interface towards (bio-)chemical agents. LAPS measurements are spatially resolved by utilisation of focused light beams to define individual measurement spots. In this work, a new digitally modulated LAPS set-up based on an FPGA design will be introduced to increase the number of measurement spots, to shorten the measurement time and to improve the measurement accuracy.
Bestimmung der metabolischen Aktivität von Mikroorganismen während des Biogasbildungsprozesses
(2009)
Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection
(2010)
Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs
(2010)
Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors
(2009)
Microfabrication, characterization and analytical application of a new thin-film silver microsensor
(2009)