Refine
Year of publication
- 2003 (254) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (57)
- Fachbereich Elektrotechnik und Informationstechnik (33)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Wirtschaftswissenschaften (31)
- INB - Institut für Nano- und Biotechnologien (30)
- Fachbereich Energietechnik (25)
- IfB - Institut für Bioengineering (24)
- Fachbereich Luft- und Raumfahrttechnik (21)
- Fachbereich Bauingenieurwesen (20)
- Fachbereich Chemie und Biotechnologie (14)
Language
- German (147)
- English (106)
- Portuguese (1)
Document Type
- Article (154)
- Conference Proceeding (40)
- Book (29)
- Part of a Book (11)
- Course Material (7)
- Patent (5)
- Part of a Periodical (3)
- Other (2)
- Doctoral Thesis (1)
- Report (1)
Keywords
- Blitzschutz (6)
- Lightning protection (6)
- CAD (4)
- Clusterion (4)
- Air purification (3)
- Auslenkung (3)
- Bauingenieurwesen (3)
- Fachhochschule Aachen (3)
- Javasimulation (3)
- Luftreiniger (3)
Härtebegriff im Zusammenhang mit Vernetzung, Bruchdehnung und Dauerfestigkeit eines Elastomers
(2003)
Layer Deposition I
(2003)
Sonderbilanz und Status
(2003)
3D-Freiformflächenmessung
(2003)
Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
(2003)
A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.
Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
(2003)
A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.
ComputerMathematik mit Maple
(2003)
Untersuchung eines hybriden EMV-Simulationsverfahrens anhand eines virtuellen Komponententests
(2003)
Mauerwerksbauten
(2003)
Production and distribution of personalized information services employing mass customization
(2003)
This paper presents the direct route to Design by Analysis (DBA) of the new European pressure vessel standard in the language of limit and shakedown analysis (LISA). This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for some examples from the DBA-Manual. One observation from the examples is, that the optimisation approach gives reliable and close lower bound solutions leading to simple and optimised design decision.