Refine
Year of publication
- 2009 (121) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- INB - Institut für Nano- und Biotechnologien (26)
- IfB - Institut für Bioengineering (23)
- Fachbereich Elektrotechnik und Informationstechnik (18)
- Fachbereich Chemie und Biotechnologie (13)
- Fachbereich Luft- und Raumfahrttechnik (7)
- Fachbereich Energietechnik (5)
- Fachbereich Wirtschaftswissenschaften (4)
- Fachbereich Maschinenbau und Mechatronik (3)
- Freshman Institute (2)
Has Fulltext
- no (121)
Language
- English (121) (remove)
Document Type
- Article (121) (remove)
Keywords
- EGG (1)
- Larynx position (1)
- Tomography (1)
- Transfer impedance (1)
- Voice assessment (1)
- avalanche (1)
- cardiac gating (1)
- cardiovascular MR imaging (1)
- electrocardiogram (1)
- high field MR imaging (1)
- phonocardiogram (1)
- snow (1)
The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics.
A new solar desalination system with heat recovery for decentralised drinking water production
(2009)
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.
The simultaneous assessment of glottal dynamics and larynx position can be beneficial for the diagnosis of disordered voice or speech production and swallowing. Up to now, methods either concentrate on assessment of the glottis opening using optical, acoustical or electrical (electroglottography, EGG) methods, or on visualisation of the larynx position using ultrasound, computer tomography or magnetic resonance imaging techniques.
The method presented here makes use of a time-multiplex measurement approach of space-resolved transfer impedances through the larynx. The fast sequence of measurements allows a quasi simultaneous assessment of both larynx position and EGG signal using up to 32 transmit–receive signal paths. The system assesses the dynamic opening status of the glottis as well as the vertical and back/forward motion of the larynx.
Two electrode-arrays are used for the measurement of the electrical transfer impedance through the neck in different directions. From the acquired data the global and individual conductivity is calculated as well as a 2D point spatial representation of the minimum impedance.
The position information is shown together with classical EGG signals allowing a synchronous visual assessment of glottal area and larynx position. A first application to singing voice analysis is presented that indicate a high potential of the method for use as a non-invasive tool in the diagnosis of voice, speech, and swallowing disorders.
Unravelling the factors determining the allocation of carbon to various plant organs is one of the great challenges of modern plant biology. Studying allocation under close to natural conditions requires non-invasive methods, which are now becoming available for measuring plants on a par with those developed for humans. By combining magnetic resonance imaging (MRI) and positron emission tomography (PET), we investigated three contrasting root/shoot systems growing in sand or soil, with respect to their structures, transport routes and the translocation dynamics of recently fixed photoassimilates labelled with the short-lived radioactive carbon isotope 11C. Storage organs of sugar beet (Beta vulgaris) and radish plants (Raphanus sativus) were assessed using MRI, providing images of the internal structures of the organs with high spatial resolution, and while species-specific transport sectoralities, properties of assimilate allocation and unloading characteristics were measured using PET. Growth and carbon allocation within complex root systems were monitored in maize plants (Zea mays), and the results may be used to identify factors affecting root growth in natural substrates or in competition with roots of other plants. MRI–PET co-registration opens the door for non-invasive analysis of plant structures and transport processes that may change in response to genomic, developmental or environmental challenges. It is our aim to make the methods applicable for quantitative analyses of plant traits in phenotyping as well as in understanding the dynamics of key processes that are essential to plant performance.
Density Operator
(2009)
The powerful avalanche simulation toolbox RAMMS (Rapid Mass Movements) is based on a depth-averaged
hydrodynamic system of equations with a Voellmy-Salm friction relation. The two empirical friction parameters
μ and correspond to a dry Coulomb friction and a viscous resistance, respectively. Although μ and lack a
proper physical explanation, 60 years of acquired avalanche data in the Swiss Alps made a systematic calibration
possible. RAMMS can therefore successfully model avalanche flow depth, velocities, impact pressure and run
out distances. Pudasaini and Hutter (2003) have proposed extended, rigorously derived model equations that
account for local curvature and twist. A coordinate transformation into a reference system, applied to the actual
mountain topography of the natural avalanche path, is performed. The local curvature and the twist of the
avalanche path induce an additional term in the overburden pressure. This leads to a modification of the Coulomb
friction, the free-surface pressure gradient, the pressure induced by the channel, and the gravity components
along and normal to the curved and twisted reference surface. This eventually guides the flow dynamics and
deposits of avalanches. In the present study, we investigate the influence of curvature on avalanche flow in
real mountain terrain. Simulations of real avalanche paths are performed and compared for the different models
approaches. An algorithm to calculate curvature in real terrain is introduced in RAMMS. This leads to a curvature
dependent friction relation in an extended version of the Voellmy-Salm model equations. Our analysis provides
yet another step in interpreting the physical meaning and significance of the friction parameters used in the
RAMMS computational environment.
Embedding fuzzy controllers in golog / Ferrein, Alexander ; Schiffer, Stefan ; Lakemeyer, Gerhard
(2009)
Enhanced system architecture for rugged wide band data transmission / Sadeghfam, A. ; Heuermann, H.
(2009)
Expeditious building of ring-porous earlywood vessel chronologies without loosing signal information
(2009)
Fundamentals and ignition of a microplasma at 2.45 GHZ / Holtrup, Stephan ; Heuermann, Holger
(2009)
Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors
(2009)
Magnetotomography and Electric Currents in a Fuel Cell / Lustfeld, H. ; Reißel, M. ; Steffen, B.
(2009)
Microfabrication, characterization and analytical application of a new thin-film silver microsensor
(2009)
This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T₂ mapping of the heart. First, T₂ maps are presented for oil phantoms without and with respiratory motion emulation (T₂ = (22.1 ± 1.7) ms at 1.5 T and T₂ = (22.65 ± 0.89) ms at 3.0 T). T₂ relaxometry of a ferrofluid revealed relaxivities of R2 = (477.9 ± 17) mM⁻¹s⁻¹ and R2 = (449.6 ± 13) mM⁻¹s⁻¹ for UFLARE and multiecho gradient-echo imaging at 1.5 T. For inferoseptal myocardial regions mean T₂ values of 29.9 ± 6.6 ms (1.5 T) and 22.3 ± 4.8 ms (3.0 T) were estimated. For posterior myocardial areas close to the vena cava T₂-values of 24.0 ± 6.4 ms (1.5 T) and 15.4 ± 1.8 ms (3.0 T) were observed. The merits and limitations of the proposed approach are discussed and its implications for cardiac and vascular T₂-mapping are considered.
Next Generation Access Networks: Why is there a higher risk of investment and how to deal with it?
(2009)
Operator
(2009)
Projection
(2009)