Refine
Year of publication
- 2022 (304) (remove)
Institute
- Fachbereich Gestaltung (106)
- Fachbereich Medizintechnik und Technomathematik (51)
- Fachbereich Energietechnik (37)
- IfB - Institut für Bioengineering (27)
- ECSM European Center for Sustainable Mobility (23)
- Fachbereich Chemie und Biotechnologie (20)
- Fachbereich Elektrotechnik und Informationstechnik (19)
- Fachbereich Wirtschaftswissenschaften (17)
- Fachbereich Luft- und Raumfahrttechnik (15)
- Fachbereich Maschinenbau und Mechatronik (15)
Language
- German (157)
- English (146)
- Multiple languages (1)
Document Type
- Bachelor Thesis (94)
- Article (92)
- Conference Proceeding (49)
- Part of a Book (31)
- Book (11)
- Master's Thesis (11)
- Conference: Meeting Abstract (5)
- Report (3)
- Conference Poster (2)
- Other (2)
Keywords
- Illustration (8)
- Fotografie (6)
- Gesundheit (6)
- App (5)
- Erscheinungsbild (5)
- Kampagne (4)
- Kurzfilm (4)
- Animation (3)
- Concentrated solar power (3)
- Corporate Design (3)
Zugriffsart
- weltweit (99)
- campus (81)
- bezahl (20)
- fachbereichsweit (FB4) (12)
Solar thermal concentrated power is an emerging technology that provides clean electricity for the growing energy market. To the solar thermal concentrated power plant systems belong the parabolic trough, the Fresnel collector, the solar dish, and the central receiver system.
For high-concentration solar collector systems, optical and thermal analysis is essential. There exist a number of measurement techniques and systems for the optical and thermal characterization of the efficiency of solar thermal concentrated systems.
For each system, structure, components, and specific characteristics types are described. The chapter presents additionally an outline for the calculation of system performance and operation and maintenance topics. One main focus is set to the models of components and their construction details as well as different types on the market. In the later part of this article, different criteria for the choice of technology are analyzed in detail.
Am Lehr- und Forschungsgebiet Holzbau der Fachhochschule Aachen wurden im Rahmen des Forschungsvorhabens „Nachhaltige Standardbrücken in Holzbauweise“ Standardtypen für Geh- und Radwegbrücken entwickelt. Die Brücken sind durch konsequente Umsetzungen von Maßnahmen des konstruktiven Holzschutzes für eine Nutzung von mehr als 80~Jahren konzipiert. Innovative Lösungen für Bauteile und Anschlüsse sowie Materialalternativen im Bereich des Belages und der Geländer ermöglichen eine wartungsarme Konstruktion und tragen somit zur Wirtschaftlichkeit und Nachhaltigkeit bei.
Um den Einsatz der entwickelten Standardbrückentypen in der Praxis zu erleichtern, wurden Leistungsverzeichnisse, Musterstatiken, Musterzeichnungen und umfangreiche Detailkataloge als Unterstützung für Planer und Bauherren erstellt. Damit die Randbedingungen für eine lange Lebensdauer während der Nutzung der Brücke erhalten bleiben, wurden Leitfäden für die Pflege und Wartung sowie für die Brückenprüfung erarbeitet. Der Beitrag gibt Einblicke in das Forschungsvorhaben und seine Resultate.
Cybersecurity of Industrial Control Systems (ICS) is an important issue, as ICS incidents may have a direct impact on safety of people or the environment. At the same time the awareness and knowledge about cybersecurity, particularly in the context of ICS, is alarmingly low. Industrial honeypots offer a cheap and easy to implement way to raise cybersecurity awareness and to educate ICS staff about typical attack patterns. When integrated in a productive network, industrial honeypots may not only reveal attackers early but may also distract them from the actual important systems of the network. Implementing multiple honeypots as a honeynet, the systems can be used to emulate or simulate a whole Industrial Control System. This paper describes a network of honeypots emulating HTTP, SNMP, S7communication and the Modbus protocol using Conpot, IMUNES and SNAP7. The nodes mimic SIMATIC S7 programmable logic controllers (PLCs) which are widely used across the globe. The deployed honeypots' features will be compared with the features of real SIMATIC S7 PLCs. Furthermore, the honeynet has been made publicly available for ten days and occurring cyberattacks have been analyzed
This paper compares several blade element theory (BET) method-based propeller simulation tools, including an evaluation against static propeller ground tests and high-fidelity Reynolds-Average Navier Stokes (RANS) simulations. Two proprietary propeller geometries for paraglider applications are analysed in static and flight conditions. The RANS simulations are validated with the static test data and used as a reference for comparing the BET in flight conditions. The comparison includes the analysis of varying 2D aerodynamic airfoil parameters and different induced velocity calculation methods. The evaluation of the BET propeller simulation tools shows the strength of the BET tools compared to RANS simulations. The RANS simulations underpredict static experimental data within 10% relative error, while appropriate BET tools overpredict the RANS results by 15–20% relative error. A variation in 2D aerodynamic data depicts the need for highly accurate 2D data for accurate BET results. The nonlinear BET coupled with XFOIL for the 2D aerodynamic data matches best with RANS in static operation and flight conditions. The novel BET tool PropCODE combines both approaches and offers further correction models for highly accurate static and flight condition results.
Altered gastrocnemius contractile behavior in former achilles tendon rupture patients during walking
(2022)
Achilles tendon rupture (ATR) remains associated with functional limitations years after injury. Architectural remodeling of the gastrocnemius medialis (GM) muscle is typically observed in the affected leg and may compensate force deficits caused by a longer tendon. Yet patients seem to retain functional limitations during—low-force—walking gait. To explore the potential limits imposed by the remodeled GM muscle-tendon unit (MTU) on walking gait, we examined the contractile behavior of muscle fascicles during the stance phase. In a cross-sectional design, we studied nine former patients (males; age: 45 ± 9 years; height: 180 ± 7 cm; weight: 83 ± 6 kg) with a history of complete unilateral ATR, approximately 4 years post-surgery. Using ultrasonography, GM tendon morphology, muscle architecture at rest, and fascicular behavior were assessed during walking at 1.5 m⋅s–1 on a treadmill. Walking patterns were recorded with a motion capture system. The unaffected leg served as control. Lower limbs kinematics were largely similar between legs during walking. Typical features of ATR-related MTU remodeling were observed during the stance sub-phases corresponding to series elastic element (SEE) lengthening (energy storage) and SEE shortening (energy release), with shorter GM fascicles (36 and 36%, respectively) and greater pennation angles (8° and 12°, respectively). However, relative to the optimal fascicle length for force production, fascicles operated at comparable length in both legs. Similarly, when expressed relative to optimal fascicle length, fascicle contraction velocity was not different between sides, except at the time-point of peak series elastic element (SEE) length, where it was 39 ± 49% lower in the affected leg. Concomitantly, fascicles rotation during contraction was greater in the affected leg during the whole stance-phase, and architectural gear ratios (AGR) was larger during SEE lengthening. Under the present testing conditions, former ATR patients had recovered a relatively symmetrical walking gait pattern. Differences in seen AGR seem to accommodate the profound changes in MTU architecture, limiting the required fascicle shortening velocity. Overall, the contractile behavior of the GM fascicles does not restrict length- or velocity-dependent force potentials during this locomotor task.
With the growing interest in small distributed sensors for the “Internet of Things”, more attention is being paid to energy harvesting techologies. Reducing or eliminating the need for external power sources or batteries make devices more self-sufficient, more reliable, and reduces maintenance requirements. The Wiegand effect is a proven technology for harvesting small amounts of electrical power from mechanical motion.
Mit dem Beitrag des Teams der FH Aachen zum SDE 21/22 wird im Projekt LOCAL+ ein kreislauffähiger Holzmodulbau mit einem innovativen Wohnraumkonzept geplant und umgesetzt. Ziel dieses Konzeptes ist die Verringerung des stetig steigenden Wohnflächenbedarfs durch ein Raum-in-Raum Konzept. Gebäudetechnisch wird in dem Projekt nicht nur das Einzelgebäude betrachtet, sondern unter Berücksichtigung des Gebäudebestandes wird für das Quartier ein innovatives und nachhaltiges Energiekonzept entwickelt. Ein zentrales Wasserstoffsystem ist für ein Quartier geplant, um den Stromverbrauch aus dem Netz im Winter zu reduzieren. Zentraler Bestandteil des TGA-Konzepts ist ein unterirdischer Eisspeicher, eine PVT und eine Wärmepumpe mit intelligenter Regelstrategie. Ein Teil des neuen Gebäudes (Design Challenge DC) wird in Wuppertal als Hausdemonstrationseinheit (HDU) präsentiert. Eine hygrothermische Simulation der HDU wurde mit der WUFI-Software durchgeführt. Da im Innenraum Lehmmodule und -platten als Feuchtigkeitspuffer verwendet werden, spielen die Themen Feuchtigkeit, Holzfäule und Schimmelwachstum eine wichtige Rolle.
Chromatography is the workhorse of biopharmaceutical downstream processing because it can selectively enrich a target product while removing impurities from complex feed streams. This is achieved by exploiting differences in molecular properties, such as size, charge and hydrophobicity (alone or in different combinations). Accordingly, many parameters must be tested during process development in order to maximize product purity and recovery, including resin and ligand types, conductivity, pH, gradient profiles, and the sequence of separation operations. The number of possible experimental conditions quickly becomes unmanageable. Although the range of suitable conditions can be narrowed based on experience, the time and cost of the work remain high even when using high-throughput laboratory automation. In contrast, chromatography modeling using inexpensive, parallelized computer hardware can provide expert knowledge, predicting conditions that achieve high purity and efficient recovery. The prediction of suitable conditions in silico reduces the number of empirical tests required and provides in-depth process understanding, which is recommended by regulatory authorities. In this article, we discuss the benefits and specific challenges of chromatography modeling. We describe the experimental characterization of chromatography devices and settings prior to modeling, such as the determination of column porosity. We also consider the challenges that must be overcome when models are set up and calibrated, including the cross-validation and verification of data-driven and hybrid (combined data-driven and mechanistic) models. This review will therefore support researchers intending to establish a chromatography modeling workflow in their laboratory.