Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1546)
- Fachbereich Wirtschaftswissenschaften (700)
- Fachbereich Elektrotechnik und Informationstechnik (630)
- Fachbereich Energietechnik (598)
- Fachbereich Chemie und Biotechnologie (588)
- INB - Institut für Nano- und Biotechnologien (524)
- Fachbereich Maschinenbau und Mechatronik (470)
- IfB - Institut für Bioengineering (429)
- Fachbereich Luft- und Raumfahrttechnik (368)
- Fachbereich Bauingenieurwesen (327)
Has Fulltext
- no (5530) (remove)
Language
Document Type
- Article (5530) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- SLM (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface.
A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture.
Game-based learning is a promising approach to anti-phishing education, as it fosters motivation and can help reduce the perceived difficulty of the educational material. Over the years, several prototypes for game-based applications have been proposed, that follow different approaches in content selection, presentation, and game mechanics. In this paper, a literature and product review of existing learning games is presented. Based on research papers and accessible applications, an in-depth analysis was conducted, encompassing target groups, educational contexts, learning goals based on Bloom’s Revised Taxonomy, and learning content. As a result of this review, we created the publications on games (POG) data set for the domain of anti-phishing education. While there are games that can convey factual and conceptual knowledge, we find that most games are either unavailable, fail to convey procedural knowledge or lack technical depth. Thus, we identify potential areas of improvement for games suitable for end-users in informal learning contexts.
A Portable Implementation of Index Sequential Input-Output [Part 1] / Kurbel, Karl; Pietsch, W.
(1986)
A Portable Implementation of Index Sequential Input-Output [Part 2] / Kurbel, Karl; Pietsch, W.
(1986)
The following article deals with the basic principles of intercultural management and possible improvements in terms of cultural, ethnic and gender diversification. The results are exemplarily applied to a bank located in Germany. The aim of this paper is to find out to what extent intercultural management could improve the productivity of Relatos-Bank in dealing with foreign employees or employees with a different cultural background. To achieve this goal, the authors con-duct a literature research. The main sources of information are books, journal articles and internet sources. It becomes clear that especially the different perceptions of different generations have a potential for conflict, which can be counteracted by applying presented scientific models. Equalizing the salaries of female and male employees and equalizing the rights and distribution of power could also be the key to becoming an open-minded, dynamic and fair organization that is pre-pared for the rapidly changing environment in which it operates.
A second-order L-stable exponential time-differencing (ETD) method is developed by combining an ETD scheme with approximating the matrix exponentials by rational functions having real distinct poles (RDP), together with a dimensional splitting integrating factor technique. A variety of non-linear reaction-diffusion equations in two and three dimensions with either Dirichlet, Neumann, or periodic boundary conditions are solved with this scheme and shown to outperform a variety of other second-order implicit-explicit schemes. An additional performance boost is gained through further use of basic parallelization techniques.
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.
Biopharmaceuticals such as antibodies are produced in cultivated mammalian cells, which must be monitored to comply with good manufacturing practice. We, therefore, developed a fully automated system comprising a specific exhaust gas analyzer, inline analytics and a corresponding algorithm to precisely determine the oxygen uptake rate, carbon dioxide evolution rate, carbon dioxide transfer rate, transfer quotient and respiratory quotient without interrupting the ongoing cultivation, in order to assess its reproducibility. The system was verified using chemical simulation experiments and was able to measure the respiratory activity of hybridoma cells and DG44 cells (derived from Chinese hamster ovary cells) with satisfactory results at a minimum viable cell density of ~2.0 × 10⁵ cells ml⁻¹. The system was suitable for both batch and fed-batch cultivations in bubble-aerated and membrane-aerated reactors, with and without the control of pH and dissolved oxygen.