Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (638) (remove)
Document Type
- Article (638) (remove)
Keywords
- Multimediamarkt (6)
- Hot S-parameter (2)
- Literaturanalyse (2)
- MINLP (2)
- Referenzmodellierung (2)
- 197m/gHg (1)
- 3-D printing (1)
- Anwendungsorientierter Forschungsansatz (1)
- Arbeit 4.0 (1)
- Automated driving (1)
An experimental command and control information system based on Enterprise Java bean technology
(2002)
7T MR Safety
(2021)
Universelle hydraulische Try-Out Presse / Teilprojekt A6 / Wiendahl, H.-P. ; Doege, E. ; Engels, E.
(1999)
Pressen - Vergleich zwischen Raumlenker- und Exzenterantrieb / Doege, Eckhart ; Engels, Elmar
(1999)
Pressen - Hubzahlregelung an Schnelläuferpressen mit Fuzzy-Reglern / Doege, Eckhart ; Engels, Elmar
(1998)
This paper describes the realization of a novel neurocomputer which is based on the concepts of a coprocessor. In contrast to existing neurocomputers the main interest was the realization of a scalable, flexible system, which is capable of computing neural networks of arbitrary topology and scale, with full independence of special hardware from the software's point of view. On the other hand, computational power should be added, whenever needed and flexibly adapted to the requirements of the application. Hardware independence is achieved by a run time system which is capable of using all available computing power, including multiple host CPUs and an arbitrary number of neural coprocessors autonomously. The realization of arbitrary neural topologies is provided through the implementation of the elementary operations which can be found in most neural topologies.
The development and analysis of three waveguides for the exposure of small biological in vitro samples to mobile communication signals at 900 MHz (GSM, Global System for Mobile Communications), 1.8 GHz (GSM), and 2 GHz (UMTS, Universal Mobile Telecommunications System) is presented. The waveguides were based on a fin-line concept and the chamber containing the samples bathed in extracellular solution was placed onto two fins with a slot in between, where the exposure field concentrates. Measures were taken to allow for patch clamp recordings during radiofrequency (RF) exposure. The necessary power for the achievement of the maximum desired specific absorption rate (SAR) of 20 W/kg (average over the mass of the solution) was approximately Pin = 50 mW, Pin = 19 mW, and Pin = 18 mW for the 900 MHz, 1800 MHz, and 2 GHz devices, respectively. At 20 W/kg, a slight RF-induced temperature elevation in the solution of no more than 0.3 °C was detected, while no thermal offsets due to the electromagnetic exposure could be detected at the lower SAR settings (2, 0.2, and 0.02 W/kg). A deviation of 10% from the intended solution volume yielded a calculated SAR deviation of 8% from the desired value. A maximum ±10% variation in the local SAR could occur when the position of the patch clamp electrode was altered within the area where the cells to be investigated were located.