Refine
Year of publication
- 2004 (75) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (75) (remove)
Language
- English (75) (remove)
Document Type
- Article (68)
- Conference Proceeding (4)
- Book (3)
Keywords
- Bauingenieurwesen (2)
- CAD (2)
- civil engineering (2)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Einspielen <Werkstoff> (1)
- Fehlerstellen (1)
- Fibroblast (1)
- Fließgrenze (1)
IASSE-2004 - 13th International Conference on Intelligent and Adaptive Systems and Software Engineering eds. W. Dosch, N. Debnath, pp. 245-250, ISCA, Cary, NC, 1-3 July 2004, Nice, France We introduce a UML-based model for conceptual design support in civil engineering. Therefore, we identify required extensions to standard UML. Class diagrams are used for elaborating building typespecific knowledge: Object diagrams, implicitly contained in the architect’s sketch, are validated against the defined knowledge. To enable the use of industrial, domain-specific tools, we provide an integrated conceptual design extension. The developed tool support is based on graph rewriting. With our approach architects are enabled to deal with semantic objects during early design phase, assisted by incremental consistency checks.
This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.
Mechanical stimulation of the cells resulted in evident changes in the cell morphology, protein composition and gene expression. Microscopically, additional formation of stress fibers accompanied by cell re-arrangements in a monolayer was observed. Also, significant activation of p53 gene was revealed as compared to control. Interestingly, the use of CellTech membrane coating induced cell death after mechanical stress had been applied. Such an effect was not detected when fibronectin had been used as an adhesion substrate.