Refine
Year of publication
Document Type
- Conference Proceeding (127)
- Article (81)
- Part of a Book (27)
- Book (9)
- Report (3)
- Diploma Thesis (1)
- Doctoral Thesis (1)
- Talk (1)
Language
- English (135)
- German (114)
- Multiple languages (1)
Keywords
- Earthquake (5)
- Seismic design (4)
- INODIS (3)
- Out-of-plane load (3)
- Seismic loading (3)
- earthquakes (3)
- Adjacent buildings (2)
- Historical centres (2)
- INSYSME (2)
- Masonry infill (2)
- Shake table test (2)
- Stone masonry (2)
- Tanks (2)
- industrial facilities (2)
- installations (2)
- piping (2)
- seismic design (2)
- seismic loading (2)
- Artificial intelligence (1)
- Ausfachungsmauerwerk (1)
Institute
- Fachbereich Energietechnik (250) (remove)
Multi-dimensional fragility analysis of a RC building with components using response surface method
(2017)
Conventional fragility curves describe the vulnerability of the main structure under external hazards. However, in complex structures such as nuclear power plants, the safety or the risk depends also on the components associated with a system. The classical fault tree analysis gives an overall view of the failure and contains several subsystems to the main event, however, the interactions in the subsystems are not well represented. In order to represent the interaction of the components, a method suggested by Cimellaro et al. (2006) using multidimensional performance limit state functions to obtain the system fragility curves is adopted. This approach gives the possibility of deriving the cumulative fragility taking into account the interaction of the response of different components. In this paper, this approach is used to evaluate seismic risk of a representative electrical building infrastructure, including the component, of a nuclear power plant. A simplified model of the structure, with nonlinear material behavior is employed for the analysis in Abaqus©. The input variables considered are the material parameters, boundary conditions and the seismic input. The variability of the seismic input is obtained from selected ground motion time histories of spectrum compatible synthetic ccelerograms. Unlike the usual Monte Carlo methods used for the probabilistic analysis of the structure, a computationally effective response surface method is used. This method reduces the computational effort of the calculations by reducing the required
number of samples.
The seismic performance and safety of major European industrial facilities has a global interest for Europe, its citizens and economy. A potential major disaster at an industrial site could affect several countries, probably far beyond the country where it is located. However, the seismic design and safety assessment of these facilities is practically based on national, often outdated seismic hazard assessment studies, due to many reasons, including the absence of a reliable, commonly developed seismic hazard model for whole Europe. This important gap is no more existing, as the 2020 European Seismic Hazard Model ESHM20 was released in December 2021. In this paper we investigate the expected impact of the adoption of ESHM20 on the seismic demand for industrial facilities, through the comparison of the ESHM20 probabilistic hazard at the sites where industrial facilities are located with the respective national and European regulations. The goal of this preliminary work in the framework of Working Group 13 of the European Association for Earthquake Engineering (EAEE), is to identify potential inadequacies in the design and safety control of existing industrial facilities and to highlight the expected impact of the adoption of the new European Seismic Hazard Model on the design of new industrial facilities and the safety assessment of existing ones.
Globale Stabilitätsanalysen zylindrischer, seismisch belasteter Tanks auf numerischer Grundlage
(2015)
Analysis Of Base Isolated Liquid Storage Tanks With 3D Fsi-Analysis As Well As Simplified Approaches
(2017)
Tanks are preferably designed, for cost-saving reasons, as circular, cylindrical, thin-walled shells. In case of seismic excitation, these constructions are highly vulnerable to stability failures. An earthquake-resistant design of rigidly supported tanks for high seismic loading demands, however, uneconomic wall thicknesses. A cost-effective alternative can be provided by base isolation systems. In this paper, a simplified seismic design procedure for base isolated tanks is introduced, by appropriately modifying the standard mechanical model for flexible, rigidly supported tanks. The non-linear behavior of conventional base isolation systems becomes an integral part of a proposed simplified process, which enables
the assessment of the reduced hydrodynamic forces acting on the tank walls and the corresponding stress distribution. The impulsive and convective actions of the liquid are taken into account. The validity of this approach is evaluated by
employing a non-linear fluid-structure interaction algorithm of finite element method. Special focus is placed on the boundary conditions imposed from the base isolation and the resulting hydrodynamic pressures. Both horizontal and vertical
component of ground motion are considered in order to study the principal effects of the base isolation on the pressure distribution of the tank walls. The induced rocking effects associated with elastomeric bearings are discussed. The results
manifest that base isolated tanks can be designed for seismic loads by means of the proposed procedure with sufficient accuracy, allowing to dispense with numerically expensive techniques.
The article presents the investigation of the seismic behaviour of a modern URM building located in the municipality of Finale Emilia in province of Modena, Northern Italy. The building is situated in the centre of the series of the 2012 Northern Italy earthquakes and has not suffered any damage during the earthquake series in 2012. The observed earthquake resistance of the building is compared with predicted resistances based on linear and nonlinear design approaches according to Eurocode. Furthermore, probabilistic analyses based on nonlinear calculation models taking into account scattering of the most relevant input parameters are carried out to identify their influence to the results and to derive fragility curves.
Eine seismische Anregung verursacht in einem Flüssigkeitstank einen kombinierten Spannungszustand, was zu einem Stabilitätsversagen der häufig sehr dünnwandigen Konstruktionen führen kann. Für die Durchführung von Stabilitätsnachweisen stehen verschiedene Verfahren zur Verfügung. Üblicherweise werden aus Gründen der Einfachheit spannungsbasierte Verfahren angewendet. Diese sind für Einheitslastfälle experimentell abgesichert, wobei eine Übertragung auf kombinierte Spannungszustände wie im Erdbebenfall nur begrenzt möglich ist. Alternativ kann ein globales, numerisches Konzept, das LBA/MNA-Verfahren, angewendet werden. Das Verfahren kombiniert eine materiell nichtlineare Berechnung (MNA) mit einer linearen Beulanalyse (LBA) und erfasst die Interaktion verschiedener gleichzeitig auftretender Beanspruchungen implizit im Nachweis. Dieser Beitrag demonstriert die Anwendung der Verfahren am Beispiel verschiedener Tankgeometrien mit Höhe/Radius-Verhältnissen zwischen 1 ≤ H/R ≤ 2 und Radius/Tankwand-Verhältnissen zwischen 500 ≤ R/t ≤ 1000 und diskutiert zusätzlich die Defizite der spannungsbasierten Nachweisverfahren.