Refine
Year of publication
Institute
- Fachbereich Gestaltung (152)
- FH Aachen (150)
- Fachbereich Medizintechnik und Technomathematik (146)
- Fachbereich Maschinenbau und Mechatronik (67)
- IfB - Institut für Bioengineering (63)
- Fachbereich Energietechnik (49)
- Fachbereich Bauingenieurwesen (47)
- Fachbereich Wirtschaftswissenschaften (39)
- Fachbereich Elektrotechnik und Informationstechnik (34)
- INB - Institut für Nano- und Biotechnologien (30)
Has Fulltext
- yes (755) (remove)
Language
- German (524)
- English (223)
- Portuguese (6)
- Multiple languages (1)
- Spanish (1)
Document Type
- Conference Proceeding (226)
- Bachelor Thesis (143)
- Article (128)
- Administrative publication (76)
- Part of a Periodical (61)
- Lecture (30)
- Book (22)
- Report (19)
- Diploma Thesis (12)
- Course Material (9)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Studien- und Prüfungsordnung (21)
Zugriffsart
- weltweit (236)
- campus (65)
- fachbereichsweit (FB4) (29)
- bezahl (3)
As one class of molecular imprinted polymers (MIPs), surface imprinted polymer (SIP)-based biosensors show great potential in direct whole-bacteria detection. Micro-contact imprinting, that involves stamping the template bacteria immobilized on a substrate into a pre-polymerized polymer matrix, is the most straightforward and prominent method to obtain SIP-based biosensors. However, the major drawbacks of the method arise from the requirement for fresh template bacteria and often non-reproducible bacteria distribution on the stamp substrate. Herein, we developed a positive master stamp containing photolithographic mimics of the template bacteria (E. coli) enabling reproducible fabrication of biomimetic SIP-based biosensors without the need for the “real” bacteria cells. By using atomic force and scanning electron microscopy imaging techniques, respectively, the E. coli-capturing ability of the SIP samples was tested, and compared with non-imprinted polymer (NIP)-based samples and control SIP samples, in which the cavity geometry does not match with E. coli cells. It was revealed that the presence of the biomimetic E. coli imprints with a specifically designed geometry increases the sensor E. coli-capturing ability by an “imprinting factor” of about 3. These findings show the importance of geometry-guided physical recognition in bacterial detection using SIP-based biosensors. In addition, this imprinting strategy was employed to interdigitated electrodes and QCM (quartz crystal microbalance) chips. E. coli detection performance of the sensors was demonstrated with electrochemical impedance spectroscopy (EIS) and QCM measurements with dissipation monitoring technique (QCM-D).
„ALIGN“ ist ein smartes Möbelsystem, das den individuellen Lebensstil und die Werte der heutigen Gesellschaft widerspiegelt. Es bietet ausreichend Stauraum und ermöglicht es, Objekte gezielt in Szene zu setzen oder in den Hintergrund zu rücken. Das vielseitige System passt sich an unterschiedliche Raum- und Nutzungsszenarien an. Es ermöglicht die individuelle Gestaltung des Wohnraums nach persönlichen Vorlieben und hilft, den Herausforderungen des modernen Lebens gerecht zu werden. „ALIGN“ – eine passende Lösung für jedes Problem.
Temporärer, mobiler Lebensraum: ein Wohnkonzept für Tinyhouses aus alten, ungenutzten Bahnwaggons
(2021)
Das Olympiagelände in München wurde im Jahre 1972 durch die Münchener S-Bahn erreichbar. Nach der Nutzung während der Olympischen Spiele wurde die Strecke weiterhin von der Linie S3angefahren, aber schließlich 1988 stillgelegt und steht seither unter Denkmalschutz. Das umfassende Gelände ist bis heute gut ausgebaut und bietet viel Raum für Freizeitaktivitäten. Nun bietet sich dieser Standort für ein neues Wohnkonzept an. Aus alten, nicht mehr nutzbaren Bahnwaggons entstehen Tinyhouse-Module. Aus dem alten Olympiabahnhof der S3 wird ein neues Viertel für junge Leute, Studenten und alle anderen, die sich vorstellen können in einem Tinyhouse zu wohnen.
Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables.
For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied.
In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.
The most of conventional methods of air purification use the power of a fan to draw in air and pass it through a filter. The problem of bacterial contamination of inner parts of such a type of air conditioners in some cases draws attention towards alternative air-cleaning systems. Some manufacturers offer to use the ozone's bactericidal and deodorizing effects, but the wide spreading of such systems is restricted by the fact that toxic effects of ozone in respect of human beings are well known. In 2000 Sharp Inc. introduced "Plasma Cluster Ions (PCI)" air purification technology, which uses plasma discharge to generate cluster ions (I 0-14 ). This technology has been developed for those customers that are conscious about health and hygiene. In our experiments, we focused on some principal aspects of plasma-generated ions application - time-dependency and irreversibility of bactericidal action, spatial and kinetic characteristics of emitted cluster particles, their chemical targets in the microbial cells.
Bacterial lipopolysaccharides (endotoxins) show strong biological effects at very low concentrations in human beings and many animals when entering the blood stream. These include affecting structure and function of organs and cells, changing metabolic functions, raising body temperature, triggering the coagulation cascade, modifying hemodynamics and causing septic shock. Because of this toxicity, the removal of even minute amounts is essential for safe parenteral administration of drugs and also for septic shock patients' care. The absence of a general method for endotoxin removal from liquid interfaces urgently requires finding new methods and materials to overcome this gap. Nanostructured carbonized plant parts is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study was comparative measurement of endotoxin- and blood proteins-related adsorption rate and adsorption capacity for different carboneous materials produced at different temperatures and under different surface modifications. As a main surface modificator, positively cbarged polymer, polyethileneimine (PEl) was used. Activated carbon materials showed good adsorption properties for LPS and some proteins used in the experiments. During the batch experiments, several techniques (dust removal, autoclaving) were used and optimized for improving the material's adsorption behavior. Also, with the results obtained it was possible to differentiate the materials according to their adsorption capacity and kinetic characteristics. Modification of the surface apparently has not affected hemoglobin binding to the adsorbent's surface. Obtained adsorption isotherms can be used as a powerful tool for designing of future column-based setups for blood purification from LPS, which is especially important for septic shock treatment.
In Zeiten der COVID-19-Pandemie ist die Aufklärung der Bevölkerung, besonders in Hygiene- und Gesundheitsfragen, wichtiger denn je. Das Deutsche Hygiene-Museum macht sich genau das zur Aufgabe. Unter Einbeziehung des Museumsprofils „Das Museum vom Menschen“ und der Architektur zwischen Bauhaus und Neoklassizismus erhält das Museum ein neues Erscheinungsbild. Dabei wird der Sammlungsaspekt gezielt visualisiert, denn das Museum zeichnet sich durch einen umfangreichen Sammlungsbestand aus. Die heterogene Sammlungsbreite macht es europaweit zu einem Unikat. Da das Museum einen Teil des Gesundheitssystems darstellt, ist das überwiegend rot gehaltene Corporate Design und die Wort-Bild-Marke eine Anlehnung an das Deutsche Rote Kreuz. Das medienübergreifende Erscheinungsbild unterstreicht somit die Werte und Besonderheiten des Museums und hat zusätzlich den Auftrag, über Hygiene und Gesundheit aufzuklären.
Monitoring-System für die Luftrettung: ergonomisches Designkonzept für den medizinischen Anwender
(2021)
Bei einem Luftrettungseinsatz hat die Herstellung der Transportfähigkeit des Patienten Priorität. Im Anschluss erfolgt das Monitoring während des Fluges.
Das Problem dabei ist: Es gibt keine einheitliche Basis zur ergonomischen Nutzung und Datenverwertung der medizinischen Geräte. Kabel, Positionierung und individuelle Displays beeinträchtigen die Anwendenden. Dies kann im schlimmsten Fall die erfolgreiche Patientenbehandlung gefährden und die Übergabe des Patienten verzögern.
Im Konzept wurden die Geräte drahtlos gestaltet. Mittels Knopfdruck am Gerät werden Daten an den Monitor übertragen. Schnell und sicher können EKG, Blutdruck, SPO2 und Temperatur gemessen und Stethoskop, Ultraschall und Videolaryngoskop verwendet werden. Ein Barcode-Scanner dokumentiert Medikamente und verbrauchte Materialien. Im Anschluss wird ein Zielkrankenhaus ausgewählt, die Ankunftszeit angezeigt und Daten protokolliert und übertragen.
Zeitfenster : Prototyp einer animierten Installation zum Thema Mesokosmos und Lebensraum Erde
(2022)
Der Prototyp des Projekts "Zeitfenster" stellt eine Installation dar, inspiriert vom Museum für Naturkunde Berlin. Die Installation besteht aus einer Animation, die an die Fenster des Dinosauriersaals im Museum pojiziert wird. Die Animation zeigt in einer Art Zeitreise, wie das Erbe der Natur aussieht und was der Mensch daraus macht. In der Zeit des Klimawandels setzt sich Design vermehrt für die Aufklärung des Naturschutzes ein. Die Animation soll die Zuschauer, ob Jung oder Alt, für die Verbindung zwischen dem Menschen und der Erde sensibilisieren. Dies wird erreicht, indem sich die Installation die atemberaubende Atmosphäre des Dinosauriersaals zu Nutze macht. Die Fenster des Saals erlauben es, die Bildnisse in beeindruckender Lebensgröße darzustellen. Im Fokus steht, dass der Prototyp ein Erlebnis konzipiert, welches nur durch das Zusammenspiel der verschiedenen Medien möglich ist.
IoT von der Stange
(2016)
Das IoT ist ohne eingebettete Systeme undenkbar. Erst kleine und kleinste Mikrocontroller mit intelligenten Kommunikationsschnittstellen und Anbindung ans Internet ermöglichen sinnvolles und flächendeckendes Einsammeln von Daten. Doch wie kompliziert ist der Einstieg in die Embedded-Welt? Dieser Artikel gibt Einblick, wie die »Arduino-Plattform« die Einstiegshürden für eingebettete Systeme dramatisch reduzieren kann.
Low-end-Embedded-Plattformen stellen eine hohe Anforderung an die Entscheidungsfähigkeit des Entwicklers: Zum nächstgrößeren Prozessor greifen und ein Betriebssystem benutzen oder doch besser auf das Betriebssystem verzichten? Die Frage lässt sich einfach beantworten: Einen Nanokernel verwenden und das Embedded-System mit einem minimalen Footprint realisieren. Adam Dunkels Protothreads sind eine ausgesprochen effiziente Art, Mikrocontroller gut strukturiert zu programmieren und gleichzeitig auf Overhead zu verzichten. So können auch mit kleinen 8-bit-Prozessoren anspruchsvolle Aufgaben in einem Thread-Modell bearbeitet werden. Man muss also nicht immer das Rad neu erfinden oder gleich auf Linux-basierte Systeme zurückgreifen.
Dr.-Ing. Martin Wolf ; Dipl.-Kaufm. Daniel Ulbrich , Dr. Pecher und Partner Ingenieurgesellschaft mbH, München. 31 S. (S. 139-168). Beitrag zum 1. Aachener Softwaretag in der Wasserwirtschaft < 1, 2007, Aachen>. Zusammenfasung [der Autoren] Die öffentlichen Kanalnetze Deutschlands stellen mit einem Wert von rd. 330 Mrd. € ein enormes Anlagevermögen dar. Auf Grund des oft schlechten Zustandes und geringer Ausgaben zur Instandhaltung und Erneuerung ist zu erwarten, dass durch die gegenwärtige Sanierungspraxis eher ein Substanzwertverzehr des Kanalnetzes als ein Substanzwerterhalt im Sinne des Generationenvertrages erzielt wird. Für einen nachhaltigen Betrieb und Erhalt der Kanalnetze sind deshalb Sanierungsstrategien erforderlich, die neben den technischen und gesetzlichen Anforderungen auch den mittel- und langfristigen Substanzwertverlauf berücksichtigen. Dieser wird beeinflusst vom erforderlichen oder durchgeführten Sanierungsumfang, Art und Zusammensetzung der ausgewählten Maßnahmen sowie der zeitlichen Abfolge der Sanierungsmaßnahmen. Erheblichen Einfluss auf den Substanzwertverlauf hat zudem die Berücksichtigung der hydraulischen Verhältnisse sowie der optisch nicht sichtbaren Undichtheiten. Entsprechend ist es erforderlich, die tatsächlich vorhandenen Defizite zu ermitteln und die Sanierungsmaßnahmen sowie eine Strategie zur Umsetzung zu erarbeiten. Da sich gezeigt hat, dass alleine die Einhaltung der technischen und gesetzlichen Anforderung für einen Substanzwerterhalt nicht ausreicht, muss die geplante Strategie im Dr.-Ing. Martin Wolf 139 von 170 Decision-Support-System kokas zur Sanierungsplanung und Strategieentwicklung 1. Aachener Softwaretag in der Wasserwirtschaft Hinblick auf die nachhaltige Wertentwicklung überprüft und ggf. Anpassungen vorgenommen werden. Kurzfristig erzielte Einsparungen durch reduzierten Schadensumfang oder einseitige Maßnahmenwahl ermöglichen zwar im günstigsten Fall, die Anforderungen einzuhalten, gehen jedoch zwangsläufig zu Lasten des Substanzwertes und führen mittel- und langfristig zu einer Verschärfung der Kosten- und Gebührensituation. Der monetäre, am konkreten Sanierungsaufwand orientierte Substanzwertansatz ermöglicht dabei, technische und kaufmännische Gesichtspunkte praxisnah zu verknüpfen und den bestmöglichen Ausgleich zwischen den gegenläufigen Zielen Substanzwerterhalt und Gebührenkonstanz zu finden.