Refine
Year of publication
- 2011 (311) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (74)
- Fachbereich Elektrotechnik und Informationstechnik (40)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Wirtschaftswissenschaften (34)
- Fachbereich Chemie und Biotechnologie (28)
- Fachbereich Energietechnik (28)
- IfB - Institut für Bioengineering (27)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Bauingenieurwesen (23)
- Fachbereich Luft- und Raumfahrttechnik (22)
Has Fulltext
- no (311) (remove)
Document Type
- Article (178)
- Conference Proceeding (70)
- Book (23)
- Part of a Book (21)
- Report (6)
- Patent (5)
- Conference: Meeting Abstract (3)
- Doctoral Thesis (2)
- Other (2)
- Contribution to a Periodical (1)
Keywords
- Aktionskunst (3)
- Interaktive Kunst (2)
- Kommunikationsguerrilla (2)
- Stadtgestaltung (2)
- Streetart (2)
- Öffentlicher Raum (2)
- Business Process (1)
- Customer Orientation (1)
- Enterprise Architecture (1)
- High field MRI (1)
- Illustration (1)
- Kinetische Kunst (1)
- Lichtkunst (1)
- MR safety (1)
- MRI (1)
- Mack, Heinz (1)
- Magneto alert sensor (1)
- McLuhan, Marshall (1)
- Meinungsäußerung (1)
- Netzkunst (1)
- Papierkunst (1)
- Pornographie (1)
- Raumerfahrung (1)
- Strickmuster (1)
- Telecommunication Industry (1)
- Transformation Project (1)
- Uktrahigh field MRI (1)
- Zuschauer (1)
- avalanche (1)
- heliosphere (1)
- ion propulsion (1)
- low-thrust trajectory optimization (1)
- snow (1)
Objective
To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil.
Methods
In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists.
Results
Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers.
Conclusion
The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value.
Das Ziel des Deutschen Corporate Governance Kodex (DCGK) besteht in der Verbesserung der Transparenz und Qualität der deutschen Corporate Governance, wobei die Sanktionierung der Nichteinhaltung des DCGK einzig durch etwaige Kapitalmarktreaktionen erfolgt. Folgende Befunde sprechen jedoch dafür, dass durch die Abgabe der Entsprechenserklärung gem. § 161 AktG die für das Enforcement des Kodex angenommene Selbstregulierung durch den Kapitalmarkt nicht stattfindet, und demnach Verbesserungsbedarf besteht
Durch die Kombination von Oligonukleotid-Liganden (Aptameren) hoher Bindungsaffinitäten
mit hochselektiv abtrennbaren magnetisierbaren Mikropartikeln
wird eine einstufige Separation von Zielmolekülen aus mikrobiologischen
Produktionsansätzen möglich. Die Aptamere werden hierfür reversibel
auf den Partikeloberflächen gebunden und für die spezifische Isolierung von
Bioprodukten eingesetzt. Die Abtrennung der beladenen Partikel erfolgt
durch einen neuen Rotor-Stator-Separator mit Hochgradient-Magnetfeld.
Werbung mit Garantien
(2011)
Hydrostatic propeller drive
(2011)