Refine
Year of publication
- 2010 (100) (remove)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (19)
- Fachbereich Medizintechnik und Technomathematik (14)
- Fachbereich Energietechnik (13)
- Fachbereich Maschinenbau und Mechatronik (12)
- Fachbereich Bauingenieurwesen (11)
- Solar-Institut Jülich (11)
- Fachbereich Luft- und Raumfahrttechnik (10)
- IfB - Institut für Bioengineering (8)
- INB - Institut für Nano- und Biotechnologien (5)
- Fachbereich Architektur (3)
Language
- English (68)
- German (30)
- Italian (1)
- Multiple languages (1)
Document Type
- Conference Proceeding (100) (remove)
Keywords
- humans (2)
- Dekontamination (1)
- Endothelzelle (1)
- Erythrozyt (1)
- Graduiertentagung (1)
- Hämoglobin (1)
- Körpertemperatur (1)
- Natriumhypochlorit (1)
- Sepsis (1)
- Sonde (1)
In aseptischen Abfüllsystemen wird Wasserstoffperoxid in der Gasphase aufgrund der stark oxidativen Wirkung zur Packstoffentkeimung eingesetzt. Dabei wird die Effizienz der Entkeimung im Wesentlichen von der vorliegenden H2O2-Konzentration im Packstoff bestimmt. Zur Inline-Überwachung der H2O2-Konzentration wurde ein kalorimetrischer Gassensor auf Basis einer flexiblen Polyimidfolie aus temperatursensitiven Dünnschicht-Widerständen und Mangan(IV)-oxid als katalytische Transducerschicht realisiert. Der Sensor weist ein lineares Ansprechverhalten mit einer Sensitivität von 7,15 °C/Vol.-% in einem H2O2-Konzentrationsbereich von 0 bis 8 Vol.-% auf. Weiterhin wurde zur Auslesung des Sensorsignals eine RFID-Elektronik, bestehend aus einem Sensor-Tag und einer Sende-/Empfangseinheit ausgelegt, sowie eine Abfolge des Messzyklus aufgestellt. Im weiteren Verlauf soll der kalorimetrische Gassensor mit der RFID-Elektronik gekoppelt und in eine Testverpackung zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen implementiert werden.
Planning the air-terminations for a structure to be protected the use of the rolling-sphere method (electro-geometrical model) is the best way from the physics of lightning point-of-view. Therefore, international standards prefer this method. However, using the rolling-sphere method only results in possible point-of-strikes on a structure without giving information about the probability of strikes at the individual points compared to others.
Large power plants can be endangered by lightning strikes with possible consequences regarding their safety and availability. A special scenario is a lightning strike to the HV overhead transmission line close to the power plant's connection to the power grid. If then additionally a so-called shielding failure of the overhead ground wire on top of the overhead transmission line is assumed, i.e. the lightning strikes directly into a phase conductor, this is an extreme electromagnetic disturbance. The paper deals with the numerical simulation of such a lightning strike and the consequences on the components of the power plant's auxiliary power network connected to different voltage levels.
Unter Energieeffizienz wird verstanden, dass ein definiertes Ziel mit möglichst wenig Energie erreicht wird. Im Beitrag wird zunächst eine Formel zur Berechnung der Gesamtenergieeffizienz eines Gebäudes angegeben. Darauf aufbauend wird ein 3-Säulen-Modell zur Energieeinsparung vorgeschlagen. Es beinhaltet vereinfachte Verfahren zur Berechnung der Betriebseigenschaften von Heizanlagen, raumlufttechnischen Anlagen und Kühl- und Kaltwasseranlagen. Am Beispiel einer RLT-Anlage wird die Vorgehensweise der Bewertung näher erläutert. Zusammenfassend wird festgestellt, dass das vereinfachte Verfahren eine schnelle und sichere energetische Bewertung der genannten Anlagen erlaubt,, zu Präsenzwissen führt, die Haupteinflussgrößen aufzeigt und eine Anlagenbewertung ohne Gebäudebewertung gewährleistet. Das vereinfachte Verfahren wird im Frühjahr 2011 verfügbar sein. Es soll Bestandteil der DIN V 18599 werden, und die EnEV 2012 soll darauf Bezug nehmen.