Refine
Year of publication
- 2013 (301) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- Fachbereich Elektrotechnik und Informationstechnik (43)
- INB - Institut für Nano- und Biotechnologien (40)
- Fachbereich Energietechnik (36)
- Fachbereich Wirtschaftswissenschaften (32)
- Fachbereich Chemie und Biotechnologie (29)
- IfB - Institut für Bioengineering (29)
- Fachbereich Luft- und Raumfahrttechnik (26)
- Fachbereich Bauingenieurwesen (17)
- Fachbereich Maschinenbau und Mechatronik (15)
Document Type
- Article (139)
- Conference Proceeding (77)
- Part of a Book (25)
- Book (24)
- Part of a Periodical (12)
- Report (9)
- Doctoral Thesis (5)
- Patent (4)
- Other (2)
- Conference: Meeting Abstract (1)
Keywords
Die Telekommunikationsindustrie hat in den letzten Jahrzehnten einen enormen Wandel vollzogen. Für Telekommunikationsunternehmen erfordert dies fundamentale Umstrukturierungen von Strategie, Prozessen, Anwendungssystemen und Netzwerktechnologien. Dabei spielen Unternehmensarchitekturen und Referenzmodelle eine wichtige Rolle. Zwar existieren in der Praxis anerkannte Referenzmodelle, aber wie sind diese für eine systematische Transformation zu gestalten? Wie sieht eine konkrete Lösung für die Telekommunikationsindustrie aus?
Als Antwort stellt Christian Czarnecki in seinem Buch eine referenzmodellbasierte Unternehmensarchitektur vor. Basierend auf einer umfangreichen Untersuchung von Transformationsprojekten werden Probleme und Anforderungen der Praxis identifiziert, für die mit Methoden der Unternehmenstransformation, Referenzmodellierung und Unternehmensarchitektur ein Lösungsvorschlag entwickelt und evaluiert wird. Dieser besteht u. a. aus detaillierten Anwendungsfällen, Referenzprozessabläufen, einer Zuordnung von Prozessen zu Anwendungssystemen sowie Handlungsempfehlungen zur Virtualisierung.
Für Wissenschaftler und Studierende der Wirtschaftsinformatik zeigt das Buch neue Erkenntnisse einer anwendungsorientierten Referenzmodellierung. Für Praktiker liefert es eine methodisch fundierte Lösung für die aktuellen Transformationsbedarfe der Telekommunikationsindustrie. Christian Czarnecki arbeitet seit 2004 als Unternehmensberater und hat viele Telekommunikationsunternehmen bei deren Transformation begleitet. In 2013 erfolgte die Promotion zum Doktoringenieur an der Otto-von-Guericke-Universität Magdeburg.
A methodology for assessment, seismic verification and strengthening of existing masonry buildings is presented in this paper. The verification is performed using a calculation model calibrated with the results from ambient vibration measurements. The calibrated model serves as an input for a deformation-based verification procedure based on the Capacity Spectrum Method (CSM). The bearing capacity of the building is calculated from experimental capacity curves of the individual walls idealized with bilinear elastic-perfectly plastic curves. The experimental capacity curves were obtained from in-plane cyclic loading tests on unreinforced and strengthened masonry walls with reinforced concrete jackets. The seismic action is compared with the load-bearing capacity of the building considering non-linear material behavior with its post-peak capacity. The application of the CSM to masonry buildings and the influence of a traditional strengthening method are demonstrated on the example of a public school building in Skopje, Macedonia.
A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.