Refine
Year of publication
- 2009 (199) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (76)
- INB - Institut für Nano- und Biotechnologien (32)
- Fachbereich Wirtschaftswissenschaften (31)
- IfB - Institut für Bioengineering (28)
- Fachbereich Elektrotechnik und Informationstechnik (23)
- Fachbereich Chemie und Biotechnologie (18)
- Fachbereich Energietechnik (15)
- Fachbereich Luft- und Raumfahrttechnik (9)
- Fachbereich Bauingenieurwesen (8)
- Fachbereich Maschinenbau und Mechatronik (8)
Document Type
- Article (199) (remove)
Keywords
- Atomausstieg (1)
- Blitzschutz (1)
- EGG (1)
- Europäische Energiepolitik (1)
- Hühnerzucht (1)
- Kernenergie (1)
- Larynx position (1)
- Tomography (1)
- Transfer impedance (1)
- Unterhaltung (1)
The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics.
A new solar desalination system with heat recovery for decentralised drinking water production
(2009)
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.
The simultaneous assessment of glottal dynamics and larynx position can be beneficial for the diagnosis of disordered voice or speech production and swallowing. Up to now, methods either concentrate on assessment of the glottis opening using optical, acoustical or electrical (electroglottography, EGG) methods, or on visualisation of the larynx position using ultrasound, computer tomography or magnetic resonance imaging techniques.
The method presented here makes use of a time-multiplex measurement approach of space-resolved transfer impedances through the larynx. The fast sequence of measurements allows a quasi simultaneous assessment of both larynx position and EGG signal using up to 32 transmit–receive signal paths. The system assesses the dynamic opening status of the glottis as well as the vertical and back/forward motion of the larynx.
Two electrode-arrays are used for the measurement of the electrical transfer impedance through the neck in different directions. From the acquired data the global and individual conductivity is calculated as well as a 2D point spatial representation of the minimum impedance.
The position information is shown together with classical EGG signals allowing a synchronous visual assessment of glottal area and larynx position. A first application to singing voice analysis is presented that indicate a high potential of the method for use as a non-invasive tool in the diagnosis of voice, speech, and swallowing disorders.
Nach der Bundestagswahl am 27. September 2009 steht der Atomausstieg in Deutschland wieder ganz oben auf der politischen Agenda. Eine aktuelle Bestandsaufnahme aller ma\geblichen Argumente erscheint somit zwingend notwendig. Dabei sollte der Blickwinkel nicht national beschränkt bleiben, sondern vor allem der Einfluss der europäischen Dimension dieser Thematik miteinbezogen werden. Auf europäischer Ebene zeigt sich eine Position zu Gunsten der Kernenergie. Unter den 27 EU-Staaten findet gerade eine Renaissance der Atomkraft statt. Die drei europäischen Organe befürworten den umfangreichen Einsatz der Kernenergie als langfristigen Bestandteil des Energieträgermix. Deutschland gehört mit seinem Beschluss zum Atomausstieg einer Minderheit an. Als Teil eines immer stärker zusammen wachsenden und letztendlich vollständig integrierten europäischen Strommarktes wird Deutschland langfristig stets mit Atomstrom versorgt werden. Dies gilt losgelöst von dem Einsatz von Kernkraftwerken im Inland. Eine Abschaltung der Anlagen führt damit nicht zur Zielerreichung der Atomkraftgegner, sondern lediglich zu zusätzlichen energietechnischen Herausforderungen bei der Sicherstellung der deutschen Stromversorgung. Der deutsche Atomausstieg sollte aus diesem Grund von der neuen Bundesregierung zurück genommen werden.