Refine
Year of publication
- 2013 (301) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- Fachbereich Elektrotechnik und Informationstechnik (43)
- INB - Institut für Nano- und Biotechnologien (40)
- Fachbereich Energietechnik (36)
- Fachbereich Wirtschaftswissenschaften (32)
- Fachbereich Chemie und Biotechnologie (29)
- IfB - Institut für Bioengineering (29)
- Fachbereich Luft- und Raumfahrttechnik (26)
- Fachbereich Bauingenieurwesen (17)
- Fachbereich Maschinenbau und Mechatronik (15)
Document Type
- Article (139)
- Conference Proceeding (77)
- Part of a Book (25)
- Book (24)
- Part of a Periodical (12)
- Report (9)
- Doctoral Thesis (5)
- Patent (4)
- Other (2)
- Conference: Meeting Abstract (1)
Keywords
Chemische Sensoren mit Bariumstrontiumtitanat als funktionelle Schicht zur Multiparameterdetektion
(2013)
Many biped robots deploy a form of gait that follows the zero moment point (ZMP) approach, that is, the robot is in a stable position at any point in time. This requires the robot to be fully actuated. While very stable, the draw-backs of this approach are a fairly slow gait and high energy consumption. An alternative approach is the so-called passive-dynamic walking, where the gait makes use of the inertia and dynamic stability of the robot. In this paper we describe our ongoing work of combining the principles of passive-dynamic walking on the fully-actuated biped robot Nao, which is also deployed for robotic soccer applications. We present a simple controller that allows the robot to stably rock sidewards, showing a closed limit-cycle. We discuss first results of superimposing a forward motion on the sidewards motion. Based on this we expect to endow the Nao with a fast, robust, and stable passive-dynamic walk on the fully-actuated Nao in the future.
The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte–insulator–semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance–voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed.
Purpose
To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T.
Methods
The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study.
Results
Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly.
Conclusion
The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.
Erfolgreiches IT-Marketing
(2013)
We have developed a double-tuned ¹H/¹⁹F birdcage resonator dedicated for hand and wrist imaging at 7 T to locally image non-steroidal anti-inflammatory drugs (NSAID) such as 2-{[3-(Trifluoromethyl) phenyl]amino}benzoic acid. The preliminary in vivo images acquired by the double-tuned ¹H/¹⁹F birdcage resonator demonstrate the feasibility for ¹H/¹⁹F hand- and wrist-imaging at 7 T. While the diagnostic quality of the coil needs to be assessed in patients with inflammatory rheumatoid disease, first ¹⁹F images of the NSAID are encouraging, and point towards the prospect of applying ¹⁹F-MRI to visualize and quantify the concentration of therapeutically-active compound at the sites of inflammation.