Refine
Year of publication
- 2017 (262) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (67)
- Fachbereich Elektrotechnik und Informationstechnik (37)
- IfB - Institut für Bioengineering (34)
- Fachbereich Luft- und Raumfahrttechnik (33)
- Fachbereich Wirtschaftswissenschaften (32)
- Fachbereich Energietechnik (27)
- INB - Institut für Nano- und Biotechnologien (27)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Bauingenieurwesen (14)
- Fachbereich Architektur (13)
Document Type
- Article (109)
- Conference Proceeding (87)
- Part of a Book (34)
- Book (14)
- Other (11)
- Part of a Periodical (2)
- Report (2)
- Contribution to a Periodical (1)
- Doctoral Thesis (1)
- Patent (1)
Keywords
- Autonomous mobile robots (2)
- Gamification (2)
- Industry 4.0 (2)
- MASCOT (2)
- Multi-robot systems (2)
- Smart factory (2)
- 3D nonlinear finite element model (1)
- Acceptance tests (1)
- Ausfachungsmauerwerk (1)
- Automated Optimization (1)
Is part of the Bibliography
- no (262)
Extrem hohe Blitzströme
(2017)
The invention pertains to a CellDrum electrode arrangement for measuring mechanical stress, comprising a mechanical holder (1 ) and a non-conductive membrane (4), whereby the membrane (4) is at least partially fixed at its circumference to the mechanical holder (1), keeping it in place when the membrane (4) may bend due to forces acting on the membrane (4), the mechanical holder (1) and the membrane (4) forming a container, whereby the membrane (1) within the container comprises an cell- membrane compound layer or biological material (3) adhered to the deformable membrane 4 which in response to stimulation by an agent may exert mechanical stress to the membrane (4) such that the membrane bending stage changes whereby the container may be filled with an electrolyte, whereby an electric contact (2) is arranged allowing to contact said electrolyte when filled into to the container, whereby within a predefined geometry to the fixing of the membrane (4) an electrode (7) is arranged, whereby the electrode (7) is electrically insulated with respect to the electric contact (2) as well as said electrolyte, whereby mechanical stress due to an agent may be measured as a change in capacitance.
Genetically humanized mice for proteins involved in drug metabolism and toxicity and mice engrafted with human hepatocytes are emerging as promising in vivo models for improved prediction of the pharmacokinetic, drug–drug interaction, and safety characteristics of compounds in humans. This is an overview on the genetically humanized and chimeric liver-humanized mouse models, which are illustrated with examples of their utility in drug metabolism and toxicity studies. The models are compared to give guidance for selection of the most appropriate model by highlighting advantages and disadvantages to be carefully considered when used for studies in drug discovery and development.
The Pharmacokinetics and Metabolism of Lumiracoxib in Chimeric Humanized and Murinized FRG Mice
(2017)
Small Claims Regulation
(2017)
Names of individuals
(2017)
This chapter introduces performance and acceptance testing and describes state-of-the-art tools, methods, and instruments to assess the plant performance or realize plant acceptance testing. The status of the development of standards for performance assessment is given.