Refine
Year of publication
Document Type
- Conference Proceeding (227) (remove)
Language
- English (130)
- German (95)
- Multiple languages (1)
- Spanish (1)
Has Fulltext
- yes (227) (remove)
Keywords
- Biosensor (25)
- Blitzschutz (15)
- CAD (11)
- Finite-Elemente-Methode (11)
- civil engineering (11)
- Bauingenieurwesen (10)
- Lightning protection (9)
- Einspielen <Werkstoff> (6)
- Telekommunikationsmarkt (6)
- shakedown analysis (6)
- Graduiertentagung (5)
- Clusterion (4)
- Führung (4)
- Kanalisation (4)
- Leadership (4)
- Sonde (4)
- limit analysis (4)
- reinforced concrete (4)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (3)
- Absolvententreffen (3)
Institute
- Fachbereich Medizintechnik und Technomathematik (91)
- IfB - Institut für Bioengineering (38)
- Fachbereich Bauingenieurwesen (36)
- Fachbereich Energietechnik (33)
- Fachbereich Maschinenbau und Mechatronik (19)
- Fachbereich Elektrotechnik und Informationstechnik (16)
- Fachbereich Wirtschaftswissenschaften (15)
- Fachbereich Luft- und Raumfahrttechnik (11)
- INB - Institut für Nano- und Biotechnologien (11)
- FH Aachen (6)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (4)
- Solar-Institut Jülich (3)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Fachbereich Chemie und Biotechnologie (1)
- Fachbereich Gestaltung (1)
Dr.-Ing. Oliver Stoschek [u.a.] DHI Wasser und Umwelt GmbH, Syke. 14 S. (S. 45-58). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Ökologische Modelle zur Berechnung der Temperaturveränderung und den Einfluss von Kühlwasser auf die Wassertemperatur der Elbe. Die vorgelegte Arbeit wurde beauftragt und unterstützt von der ARGE Elbe im Zuge der Neuauflage des Wärmelastplans Elbe.
IEC Technical Committee 81 is currently creating the new IEC 62305 series of standards on Lightning Protection. Working Group 9 is responsible for Part 2 of this series, which deals with the assessment and management of risk its CDV (Committee Draft for Voting) stage and has been circulated to National Committees for comment. The paper details the development of the Simplified IEC Risk Assessment Calculator software tool as described in Informative Annex J of IEC62305-2 Ed.1/CDV 2. This tool is intended as a simplified implementation of the more rigorous treatment of risk management found in the written document. It is designed to be relatively intuitive for users who wish to obtain an initial assessment of risk sensitivity, but should not be considered a substitute to a full understanding of the methods provided in the standard when dealing with more complicated structures or those where greater risks to personal or system operation are involved.
Summary: This paper presents a methodology to study and understand the mechanics of stapled anastomotic behaviors by combining empirical experimentation and finite element analysis. Performance of stapled anastomosis is studied in terms of leakage and numerical results which are compared to in vitro experiments performed on fresh porcine tissue. Results suggest that leaks occur between the tissue and staple legs penetrating through the tissue.
Proceedings of the International Conference on Material Theory and Nonlinear Dynamics. MatDyn. Hanoi, Vietnam, Sept. 24-26, 2007, 8 p. In this paper, a method is introduced to determine the limit load of general shells using the finite element method. The method is based on an upper bound limit and shakedown analysis with elastic-perfectly plastic material model. A non-linear constrained optimisation problem is solved by using Newton’s method in conjunction with a penalty method and the Lagrangean dual method. Numerical investigation of a pipe bend subjected to bending moments proves the effectiveness of the algorithm.
A procedure for the evaluation of the failure probability of elastic-plastic thin shell structures is presented. The procedure involves a deterministic limit and shakedown analysis for each probabilistic iteration which is based on the kinematical approach and the use the exact Ilyushin yield surface. Based on a direct definition of the limit state function, the non-linear problems may be efficiently solved by using the First and Second Order Reliabiblity Methods (Form/SORM). This direct approach reduces considerably the necessary knowledge of uncertain technological input data, computing costs and the numerical error. In: Computational plasticity / ed. by Eugenio Onate. Dordrecht: Springer 2007. VII, 265 S. (Computational Methods in Applied Sciences ; 7) (COMPLAS IX. Part 1 . International Center for Numerical Methods in Engineering (CIMNE)). ISBN 978-1-402-06576-7 S. 186-189
Various planar technologies are employed for developing solid-state sensors having low cost, small size and high reproducibility; thin- and thick-film technologies are most suitable for such productions. Screen-printing is especially suitable due to its simplicity, low-cost, high reproducibility and efficiency in large-scale production. This technology enables the deposition of a thick layer and allows precise pattern control. Moreover, this is a highly economic technology, saving large amounts of the used inks. In the course of repetitions of the film-deposition procedure there is no waste of material due to additivity of this thick-film technology. Finally, the thick films can be easily and quickly deposited on inexpensive substrates. In this contribution, thick-film ion-selective electrodes based on ionophores as well as crystalline ion-selective materials dedicated for potentiometric measurements are demonstrated. Analytical parameters of these sensors are comparable with those reported for conventional potentiometric electrodes. All mentioned thick-film strip electrodes have been totally fabricated in only one, fully automated thickfilm technology, without any additional manual, chemical or electrochemical steps. In all cases simple, inexpensive, commercially available materials, i.e. flexible, plastic substrates and easily cured polymer-based pastes were used.
The determination of spacing, edge and end distance requirements for self-tapping screws requires numerous and comprehensive insertion tests. Yet the results of such tests cannot be transferred to other types of screws or even to screws of different diameter because of differences in shape or geometry. To reduce the effort of insertion tests a new method was developed which allows the estimation of required spacings, distances and timber thickness.
We report on the synthesis and CO gas-sensing properties of mesoporous tin(IV) oxides (SnO2). For the synthesis cetyltrimethylammonium bromide (CTABr) was used as a structure-directing agent; the resulting SnO2 powders were applied as films to commercially available sensor substrates by drop coating. Nitrogen physisorption shows specific surface areas up to 160 m2·g-1 and mean pore diameters of about 4 nm, as verified by TEM. The film conductance was measured in dependence on the CO concentration in humid synthetic air at a constant temperature of 300 °C. The sensors show a high sensitivity at low CO concentrations and turn out to be largely insensitive towards changes in the relative humidity. We compare the materials with commercially available SnO2-based sensors.
Concept, scientific research and managerial applications of Provocative Coaching, according to the „Provocative Therapy“ of Prof. Dr. Frank Farrelly (University of Wisconsin, U.S.A) in terms of an application of the Provocative Communication Style in specific situations of practical leadership, especially in the role of a coach for their subordinates.
O Perfil Reiss apresenta no resultado uma visão da estrutura dos motivos e impulsos de uma pessoa. O ponto de saída para a análise do resultado é o conhecimento de que os motivos vitais (= valores e metas de sobrevivência) formam a moldura, na qual as competências e capacidades que uma pessoa possui possam se desabrochar de forma ideal. A partir desse princípio, não existe no Perfil Reiss nenhum resultado que se possa classificar como correto ou falso, nem como bom ou mau. Uma comparação entre o resultado do Perfil Reiss e o conteúdo de uma atividade apresentada ou ambicionada dá informação sobre até que ponto a capacidade de rendimento de uma pessoa nessa posição pode vir ou virá a se desenvolver por um longo tempo.
Dr.-Ing. Martin Wolf ; Dipl.-Kaufm. Daniel Ulbrich , Dr. Pecher und Partner Ingenieurgesellschaft mbH, München. 31 S. (S. 139-168). Beitrag zum 1. Aachener Softwaretag in der Wasserwirtschaft < 1, 2007, Aachen>. Zusammenfasung [der Autoren] Die öffentlichen Kanalnetze Deutschlands stellen mit einem Wert von rd. 330 Mrd. € ein enormes Anlagevermögen dar. Auf Grund des oft schlechten Zustandes und geringer Ausgaben zur Instandhaltung und Erneuerung ist zu erwarten, dass durch die gegenwärtige Sanierungspraxis eher ein Substanzwertverzehr des Kanalnetzes als ein Substanzwerterhalt im Sinne des Generationenvertrages erzielt wird. Für einen nachhaltigen Betrieb und Erhalt der Kanalnetze sind deshalb Sanierungsstrategien erforderlich, die neben den technischen und gesetzlichen Anforderungen auch den mittel- und langfristigen Substanzwertverlauf berücksichtigen. Dieser wird beeinflusst vom erforderlichen oder durchgeführten Sanierungsumfang, Art und Zusammensetzung der ausgewählten Maßnahmen sowie der zeitlichen Abfolge der Sanierungsmaßnahmen. Erheblichen Einfluss auf den Substanzwertverlauf hat zudem die Berücksichtigung der hydraulischen Verhältnisse sowie der optisch nicht sichtbaren Undichtheiten. Entsprechend ist es erforderlich, die tatsächlich vorhandenen Defizite zu ermitteln und die Sanierungsmaßnahmen sowie eine Strategie zur Umsetzung zu erarbeiten. Da sich gezeigt hat, dass alleine die Einhaltung der technischen und gesetzlichen Anforderung für einen Substanzwerterhalt nicht ausreicht, muss die geplante Strategie im Dr.-Ing. Martin Wolf 139 von 170 Decision-Support-System kokas zur Sanierungsplanung und Strategieentwicklung 1. Aachener Softwaretag in der Wasserwirtschaft Hinblick auf die nachhaltige Wertentwicklung überprüft und ggf. Anpassungen vorgenommen werden. Kurzfristig erzielte Einsparungen durch reduzierten Schadensumfang oder einseitige Maßnahmenwahl ermöglichen zwar im günstigsten Fall, die Anforderungen einzuhalten, gehen jedoch zwangsläufig zu Lasten des Substanzwertes und führen mittel- und langfristig zu einer Verschärfung der Kosten- und Gebührensituation. Der monetäre, am konkreten Sanierungsaufwand orientierte Substanzwertansatz ermöglicht dabei, technische und kaufmännische Gesichtspunkte praxisnah zu verknüpfen und den bestmöglichen Ausgleich zwischen den gegenläufigen Zielen Substanzwerterhalt und Gebührenkonstanz zu finden.
In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.
For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied.
Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables.