Refine
Year of publication
- 2003 (154) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (39)
- INB - Institut für Nano- und Biotechnologien (27)
- Fachbereich Wirtschaftswissenschaften (25)
- Fachbereich Maschinenbau und Mechatronik (17)
- IfB - Institut für Bioengineering (15)
- Fachbereich Elektrotechnik und Informationstechnik (14)
- Fachbereich Bauingenieurwesen (13)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Energietechnik (12)
- Fachbereich Chemie und Biotechnologie (8)
Document Type
- Article (154) (remove)
Keywords
- Blitzschutz (2)
- Lightning protection (2)
- Alternative Energiequelle (1)
- Analysis (1)
- Architektur (1)
- Bauingenieurwesen (1)
- CAD (1)
- Cement infiltration (1)
- Digital Museum (1)
- Digitales Museum (1)
Rechtsfolgen vorbehaltloser Mietzahlung in Mangelkenntnis –Mehr als bloß eine Etappe beim BGH?
(2003)
Couponing
(2003)
Ein vorausschauendes Risikomanagement beinhaltet, Risiken zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent,welche Risiken sinnvoll über Versicherungen abgedeckt werden sollten. Bei Unternehmen, die mit umfangreichen elektronischenEinrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nichtverfügbarkeit der elektronischen Einrichtungen und damit derProduktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardwareschaden an der betroffenen Anlage oft bei weitem übersteigt.
Cement augmentation is an emerging surgical procedure in which bone cement is used to infiltrate and reinforce osteoporotic vertebrae. Although this infiltration procedure has been widely applied, it is performed empirically and little is known about the flow characteristics of cement during the injection process. We present a theoretical and experimental approach to investigate the intertrabecular bone permeability during the infiltration procedure. The cement permeability was considered to be dependent on time, bone porosity, and cement viscosity in our analysis. In order to determine the time-dependent permeability, ten cancellous bone cores were harvested from osteoporotic vertebrae, infiltrated with acrylic cement at a constant flow rate, and the pressure drop across the cores during the infiltration was measured. The viscosity dependence of the permeability was determined based on published experimental data. The theoretical model for the permeability as a function of bone porosity and time was then fit to the testing data. Our findings suggest that the intertrabecular bone permeability depends strongly on time. For instance, the initial permeability (60.89 mm4/N.s) reduced to approximately 63% of its original value within 18 seconds. This study is the first to analyze cement flow through osteoporotic bone. The theoretical and experimental models provided in this paper are generic. Thus, they can be used to systematically study and optimize the infiltration process for clinical practice.
The Virtual Clean Room - a new tool in teaching MST process technologies University education in high-technology fields like MST is not complete without intensive laboratory sessions. Students cannot fully grasp the complexity and the special problems related to the manufacturing of microsystems without a thorough hands-on experience in a MST clean room.
Entrauchung über Seitenwände
(2003)
Die Eignung von Baggergut als mineralische Komponente in Deponie-Oberflächenabdichtungssystemen
(2003)
Seßlestalbrücke - Verbundbrücke mit einteiligem Querschnitt / Wanzek, Thorsten; Gossla, Ulrich
(2003)
Sanierung des ehemaligen Gaswerkgeländes am Bremer Hauptbahnhof / K. Konertz ; E. Biener ; T. Sasse
(2003)
Strategies of miniaturised reference electrodes integrated in a silicon-based „one chip“ pH sensor
(2003)
Härtebegriff im Zusammenhang mit Vernetzung, Bruchdehnung und Dauerfestigkeit eines Elastomers
(2003)
Layer Deposition I
(2003)