Refine
Year of publication
- 2006 (160) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (64)
- Fachbereich Luft- und Raumfahrttechnik (21)
- IfB - Institut für Bioengineering (20)
- INB - Institut für Nano- und Biotechnologien (18)
- Fachbereich Elektrotechnik und Informationstechnik (17)
- Fachbereich Maschinenbau und Mechatronik (15)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Energietechnik (12)
- Fachbereich Wirtschaftswissenschaften (7)
- Fachbereich Bauingenieurwesen (3)
Language
- English (160) (remove)
Document Type
- Article (85)
- Conference Proceeding (61)
- Book (9)
- Lecture (2)
- Part of a Book (1)
- Master's Thesis (1)
- Report (1)
Keywords
- Biosensor (23)
- Technische Mechanik (2)
- biosensor (2)
- 3-nitrofluoranthene (1)
- Asteroid Deflection (1)
- BTEX compounds (1)
- Bauingenieurwesen (1)
- Biosensorik (1)
- Bruchmechanik (1)
- CAD (1)
Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator
(2006)
This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis.
A key feature of future broadband markets will be diversity of access technologies, meaning that numerous technologies will be exploited for broadband communication. Various factors will affect the success of these future broadband markets, the regulatory policy being one amongst others. So far, a coherent regulatory approach does not exist as to broadband markets. First results of policies so far suggest that less sector-specific regulation is likely to occur. Instead, regulators must ensure that access to networks and services of potentially dominant providers in a relevant broadband market will satisfy requirements for openness and non-discrimination. In this environment the future challenge of regulationg broadband markets will be to set the right incentives for investment into new infrastructures. This paper examines whether there is a need for the regulation of future broadband access markets an if yes, what is the appropriate regulatory tool to do so. Thereby the focus is on the analysis of European broadband markets and the regulatory approaches applied. The first section provides a description of the characteristics of future broadband markets. The second section discusses possible bottlenecks on broadband markets an their regulatory implications. The third section will examine regulatory issues concerning access to broadband networks in more detail. This will be done by comparing the regulatory approaches of European countries and the results in terms of bradband penetration. The final section will give key recommendations for a regulatory strategy on brandband access markets.
An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM.
Design of a Measurement Setup for the Impedance of Low-Resistance Plate-Conductors in the RF-Range
(2006)
Composite improvement of textile reinforced concrete by polymeric impregnation of the textiles
(2006)
This paper reports a first microbial biosensor for rapid and cost-effective determination of organophosphorus pesticides fenitrothion and EPN. The biosensor consisted of recombinant PNP-degrading/oxidizing bacteria Pseudomonas putida JS444 anchoring and displaying organophosphorus hydrolase (OPH) on its cell surface as biological sensing element and a dissolved oxygen electrode as the transducer. Surfaceexpressed OPH catalyzed the hydrolysis of fenitrothion and EPN to release 3-methyl-4-nitrophenol and p-nitrophenol, respectively, which were oxidized by the enzymatic machinery of Pseudomonas putida JS444 to carbon dioxide while consuming oxygen, which was measured and correlated to the concentration of organophosphates. Under the optimum operating conditions, the biosensor was able to measure as low as 277 ppb of fenitrothion and 1.6 ppm of EPN without interference from phenolic compounds and other commonly used pesticides such as carbamate pesticides, triazine herbicides and organophosphate pesticides without nitrophenyl substituent. The applicability of the biosensor to lake water was also demonstrated.
Application of polymers in textile reinforced concrete : from the interface to construction elements
(2006)
A concept for a sensitive micro total analysis system for high throughput fluorescence imaging
(2006)
This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background.