Refine
Year of publication
- 2007 (271) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (52)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Elektrotechnik und Informationstechnik (38)
- Fachbereich Luft- und Raumfahrttechnik (31)
- Fachbereich Bauingenieurwesen (29)
- IfB - Institut für Bioengineering (29)
- Fachbereich Energietechnik (23)
- Fachbereich Chemie und Biotechnologie (20)
- Fachbereich Maschinenbau und Mechatronik (20)
- INB - Institut für Nano- und Biotechnologien (19)
Has Fulltext
- no (271) (remove)
Document Type
- Article (170)
- Conference Proceeding (44)
- Book (28)
- Part of a Book (16)
- Patent (6)
- Contribution to a Periodical (2)
- Doctoral Thesis (2)
- Report (2)
- Bachelor Thesis (1)
Keywords
Adaptive logistics : information management for planning and control of small series assembly
(2007)
Testing of a 10 kW diffusive micro-mix combustor for hydrogen-fuelled micro-scale gas turbines
(2007)
Computational aeroelastic analysis and design of the HIRENASD wind tunnel wing model and tests
(2007)
In the Collaborative Research Center SFB 401 at RWTH Aachen University, the numerical aeroelastic method SOFIA for direct numerical aeroelastic simulation is being progressively developed. Numerical results obtained by applying SOFIA were compared with measured data of static and dynamic aeroelastic wind tunnel tests for an elastic swept wing in subsonic flow.
IT Service Deployment
(2007)
Gleichstellungsabrede – Gestaltungsmöglichkeiten und -notwendigkeiten für die betriebliche Praxis
(2007)
This work describes a procedure to yield attenuation maps from MR images which are used for the absorption correction (AC) of brain PET data. Such an approach could be mandatory for future combined PET and MRI scanners, which probably do not include a transmission facility. T1-weighted MR images were segmented into brain tissue, bone, soft tissue, and sinus; attenuation coefficients corresponding to elemental composition and density as well as to 511 keV photon energy were respectively assigned. Attenuation maps containing up to four compartments were created and forward projected into sinograms with attenuation factors which then were used for AC during reconstruction of FDG-PET data. The commonly used AC based on a radioactive (68Ge) transmission scan served as reference. The reconstructed radioactivity values obtained with the MRI-based AC were about 20% lower than those obtained with PET-based AC if the skull was not taken into account. Considering the skull the difference was still about 10%. Our investigations demonstrate the feasibility of a MRI-based AC, but revealed also the necessity of a satisfying delineation of bone thickness which tends to be underestimated in our first approach of T1-weighted MR image segmentation.